SENSIRION SFA30 Formaldehyde Sensor Module Instruction Manual
- June 6, 2024
- SENSIRION
Table of Contents
SENSATION SFA30 Formaldehyde Sensor Module Instruction
Mechanical Handling
The SFA30 formaldehyde sensor module is a mechanically sensitive device. Handle with care at all times. Avoid exerting pressure or force on the brown top side of the sensor or the black bottom side of the sensor:
For handling or assembly, hold the sensor module at the edges of the PCB:
ESD Precautions
WARNING: The SFA30 formaldehyde sensor module is susceptible to damage by electrostatic discharge (ESD). During handling and testing, suitable ESD precautions must be taken. Operators must always use proper ESD handling equipment.
- Parameter Rating
- Electrostatic discharge voltage (human body model) Class 1C (1000 V)
- Electrostatic discharge voltage (charge device model) Class C2a (500 V)
Table 1 : ESD rating of SFA30. Reproduced from the SFA30 datasheet.
In particular, avoid touching the exposed electronics or the connector pins
without suitable ESD protection.
Storage
Refer to the SFA30 datasheet for recommended storage conditions. Store the sensor in its closed original package in a clean and dry place.
Parameter | Rating | Unit |
---|---|---|
Recommended storage temperature | 10 … 30 | °C |
Recommended storage humidity | 30 … 70 | % RH |
Table 2: Recommended storage conditions for SFA30. Reproduced from the SFA30 datasheet.
Exposure to Chemicals
The SFA30 formaldehyde sensor module and its on-board Sensirion SHT humidity
and temperature sensor should be protected from volatile chemicals, in
particular at high concentrations.
The “Handling Instructions for SHTxx Humidity and Temperature Sensors” apply.
The latest version of these handling instructions is available on the
Sensirion webpage: http://www.sensirion.com/file/handling_instructions_rht.
Pay special attention to the relevant sections on “Exposure to Chemicals” as
well as “Packaging and Storage”.
Assembly
5.1 Soldering Instructions
The SFA30 formaldehyde sensor module offers two interface connection options,
a Molex Micro-Lock Plus connector and 0.1’’ pitch contact pads. Only either of
the two connection options must be used at any time. For the pin assignment of
the Molex connector please refer to the SFA30 datasheet. The pin assignment of
the 0.1” pitch pads is identical, with the left-most (square) pad being pad 1.
Sensirion generally recommends using the Molex Micro-Lock Plus connector for
SFA30 design-in. For prototyping or when the available space is tight, the
contact pads may be used.
To connect the SFA30 sensor module over the contact pads to external
electronics, a pin stripe with 0.1 inch / 2.54 mm pitch should be used. It is
recommended to solder the SFA30 by hand only. Special care should be taken to
ensure good ventilation throughout the soldering process and to keep the heat-
up of the SFA30 PCB as low as possible. Especially the SFA30 sensor cell
should not be heated up above the short-term temperature storage limit
specified in the SFA30 datasheet. Sensirion further recommends not to use any
board wash or cleaning agents for the SFA30 sensor module PCB after soldering.
Independent of the interface connection, the SFA30 sensor cell should face the
device opening in the final assembly. Please refer to the SFA design-in guide
for further recommendations on the SFA30 integration.
5.2 Conformal Coating
For some applications it may be desired to protect the electronic assembly
with a passivation. Such passivation may be achieved by conformal coating.
The SFA30 sensor module is not compatible with spray coating and dip coating.
Manual coating with a brush, dispensing and jetting can be used to apply
conformal coating on the PCB while ensuring that no coating is applied to the
sensor cell and the top surface of the humidity sensor. Already a thin layer
of coating on the top of the SFA sensor cell or the included humidity sensor
can clog the gas openings, blocking air molecules from reaching the sensing
elements and thereby destroying the sensor. A layout of the coating area is
given in Figure 1.
When selecting a conformal coating, special focus should be given to not use a
product that is outgassing large amounts of volatile organic compounds (e.g.,
aromatics) or organic nitrogen compounds (e.g., amines). The outgassing of
this substances could potentially influence the sensor readings in the final
application or contaminate the built-in humidity sensor. In any case, ensure
good ventilation throughout the application, staging and curing to prevent any
sensor pollution.
Sensirion generally recommends curing at room temperature
under good ventilation. If the selected coating process
includes a curing step at higher temperatures, the SFA30
storage conditions specified in the datasheet should be adhered to at all
times.
Sensirion tested and recommends the conformal coating listed in the table
below. This coating is known to be suitable if applied and fully cured at room
temperature under good ventilation (fresh air supply) and according to the
respective datasheet.
Manufacturer | Product |
---|---|
Chase | HumiSeal 1B51NSLU |
Table 3: Recommended conformal coating
Important Notices
6.1 Warning, Personal Injury
Do not use this product as safety or emergency stop devices or in any other
application where failure of the product could result in personal injury. Do
not use this product for applications other than its intended and authorized
use. Before installing, handling, using or servicing this product, please
consult the data sheet and application notes. Failure to comply with these
instructions could result in death or serious injury.
If the Buyer shall purchase or use SENSIRION products for any unintended or
unauthorized application, Buyer shall defend, indemnify and hold harmless
SENSIRION and its officers, employees, subsidiaries, affiliates and
distributors against all claims, costs, damages and expenses, and reasonable
attorney fees arising out of, directly or indirectly, any claim of personal
injury or death associated with such unintended or unauthorized use, even if
SENSIRION shall be allegedly negligent with respect to the design or the
manufacture of the product.
6.2 ESD Precautions
The inherent design of this component causes it to be sensitive to electrostatic discharge (ESD). To prevent ESD-induced damage and/or degradation, take customary and statutory ESD precautions when handling this product.
6.3 Warranty
SENSATION warrants solely to the original purchaser of this product for a period of 12 months (one year) from the date of delivery that this product shall be of the quality, material and workmanship defined in SENSIRION’s published specifications of the product. Within such period, if proven to be defective, SENSIRION shall repair and/or replace this product, in SENSIRION’s discretion, free of charge to the Buyer, provided that:
- notice in writing describing the defects shall be given to SENSIRION within fourteen (14) days after their appearance;
- such defects shall be found, to SENSIRION’s reasonable satisfaction, to have arisen from SENSIRION’s faulty design, material, or workmanship;
- the defective product shall be returned to SENSIRION’s factory at the Buyer’s expense; and
- the warranty period for any repaired or replaced product shall be limited to the unexpired portion of the original period.
This warranty does not apply to any equipment which has not been installed and used within the specifications recommended by SENSIRION for the intended and proper use of the equipment. EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH HEREIN, SENSATION MAKES NO WARRANTIES, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT. ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY EXCLUDED AND DECLINED.
SENSATION is only liable for defects of this product arising under the conditions of operation provided for in the datasheet and proper use of the goods. SENSATION explicitly disclaims all warranties, express or implied, for any period during which the goods are operated or stored not in accordance with the technical specifications.
SENSATION does not assume any liability arising out of any application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. All operating parameters, including without limitation recommended parameters, must be validated for each customer’s applications by the customer’s technical experts. Recommended parameters can and do vary in different applications.
SENSATION reserves the right, without further notice, (i) to change the product specifications and/or the information in this document and (ii) to improve the reliability, functions and design of this product.
Copyright© 2020, by SENSATION. CMOSens® is a trademark of Sensirion All rights reserved
Headquarters and Subsidiaries
Sensirion AG Laubisruetistr. 50
CH-8712 Staefa ZH Switzerland
phone: +41 44 306 40 00 fax: +41 44 306 40 30
info@sensirion.com
www.sensirion.com
Sensirion Taiwan Co. Ltd phone: +886 3 5506701
info@sensirion.com
www.sensirion.com
Sensirion Inc., USA phone: +1 312 690 5858 info-us@sensirion.com www.sensirion.com
Sensirion Japan Co. Ltd. phone: +81 3 3444 4940 info-jp@sensirion.com www.sensirion.co.jp
Sensirion Korea Co. Ltd. phone: +82 31 337 7700~3 info-kr@sensirion.com
www.sensirion.co.kr
Sensirion China Co. Ltd. phone: +86 755 8252 1501 info-cn@sensirion.com
www.sensirion.com.cn
To find your local representative, please visit www.sensirion.com/distributors
Revision History
Date | Revision | Changes |
---|---|---|
October 2020 | 1.0 | Initial version |
November 2020 | 1.1 | Pictures updated |
April 2021 | 1.2 | Added chapter with soldering and conformal coating |
instructions