ATEN CS682 2-Port USB 2.0 DVI KVM Switch with Audio User Guide
- June 3, 2024
- Aten
Table of Contents
ATEN CS682 2-Port USB 2.0 DVI KVM Switch with Audio
Package Contents
- 1 CS682 2-Port USB 2.0 DVI KVM Switch
- 1 Remote Port Selector
- 1 User Manual
- 1 Quick Start Guide
Requirements
Console
- A DVI monitor capable of the highest resolution that you will be using on any computer in the installation
- A USB keyboard and a USB mouse
- Speakers and microphone (optional)
Computers
The following equipment must be installed on each computer that is to be connected to the system:
- A DVI video port
- USB Type A port
- Speaker and microphone ports (optional)
Hardware Review A
Hardware Installation B
Make sure that the power to any device that you connect to the installation
has been turned off. You must unplug the power cords of any computers that
have the Keyboard Power On function.
Make sure that all devices you will be installing are properly grounded.
-
Plug your keyboard and mouse into their USB ports, located on the side of the CS682. The ports are color coded and labeled with an appropriate icon.
Note: The mouse connector is actually a USB 2.0 port, and can accept any USB compatible peripheral. You can even connect a hub to install multiple USB devices (This may require an extra power adapter). -
Plug your monitor into the DVI port, located on the front of the CS682. Power on the monitor.
-
Plug your speakers and microphone into the console audio ports, located on the front of the CS682 (Optional).
-
Plug the keyboard, monitor, mouse, and audio connectors of the KVM cables into their respective ports on the computers you are installing.
-
If you choose to use the remote port selector, plug its cable into the remote port selector jack, located on the side of the unit.
-
Power on the computers.
Note: By default the switch links to the fi rst computer that is powered on.
Operation
Manual Port Selection
Press the port selection pushbutton on the Remote Port Selector to toggle the
KVM and Audio focus between the two computers. The Port LED lights to indicate
that the computer attached to its corresponding port has the focus.
Note: Do not switch ports while a USB device is in operation. For
independent USB switching, please see the USB KVMP switches on our website.
Mouse Port Selection
Simply double-click the scroll wheel on your USB mouse to switch between ports. The mouse port switching function allows you to toggle back and forth between the ports
Hotkey Port Selection
All hotkey operations begin by tapping the Scroll Lock key twice.
Note: If using [Scroll Lock] confl icts with other programs, [Ctrl] can
be used instead.
Hotkey Summary Table
Combination | Function |
---|
[Scroll Lock] [Scroll Lock] +| [Enter]| Toggles the KVM and Audio focus
between the two ports. Note: If the KVM and Audio focus are on different
ports, only the KVM focus switches.
[k] [Enter]| Only toggles the KVM focus.
[s] [Enter]| Only toggles the Audio focus.
[a] [Enter] [n]| Starts Auto Scan. The KVM focus cycles from port to port at n
second intervals.
Note: Replace n with a number between 1 and 4 (see Scan Interval Table below).
[x] [Enter]| Toggles the hotkey invocation key between [Scroll Lock] and
[Ctrl].
[m] [Enter]| Enables/disables mouse emulation function.
[w] [Enter]| Enables/disables mouse port-switching function.
[F2] [Enter]| Activates Mac keyboard mapping.
[F3] [Enter]| Activates Sun keyboard mapping.
[F10] [Enter]| Auto detects keyboard operating platform.
[F4] [Enter]| Lists current switch settings.
[F5] [Enter]| Performs a USB keyboard and mouse reset.
[d] [Enter]| Invokes the Video Dyna Sync™ function, which stores the monitor’s
EDID to optimize display resolution.
[R] [Enter]| Resets hotkeys to the default setting.
Scan Interval Table
n | Secs. |
---|---|
1 | 3 secs. |
2 | 5 secs. (default) |
3 | 10 secs. |
4 | 20 secs. |
Troubleshooting
Symptom | Possible Cause | Action |
---|---|---|
Monitor does not display after the KVM cable set is hot-plugged. | DVI graphics | |
card is not compatible with cable set hot-plugging. | Power off all devices on |
the installation; power off the CS682; confirm all KVM cables are properly
connected; power on the CS682; power on the computers.
Graphics card driver is not up-to-date.| Upgrade to the latest graphics card
driver.
Mouse and/or keyboard is not responding.| Switch needs to be reset.| Power off
all devices on the installation; power off the CS682; wait five seconds; power
on the CS682 again.
Mouse port-switching function is not responding.| Mouse does not support this
function.| This feature is only supported by USB 3-key scroll wheel mice.
Mouse emulation is disabled.| Enable mouse emulation.
Cannot switch ports by pressing [Scroll Lock] twice.| Keyboard is incompatible
with [Scroll Lock] invocation.| Switch to the alternate HSM invocation keys.
Support and Documentation Notice
All information, documentation, fi rewire, software utilities, and specific
cations contained in this package are subject to change without prior notify
cation by the manufacturer.
To reduce the environmental impact of our products, ATEN documentation and
software can be found online at
http://www.aten.com/download/
Technical Support
www.aten.com/support
Scan for more information
EMC Information
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
FCC Caution: Any changes or modifi cations not expressly approved by the
party responsible for compliance could void the user’s authority to operate
this equipment.
Warning: Operation of this equipment in a residential environment could
cause radio interference.
Suggestion: Shielded twisted pair (STP) cables must be used with the unit
to ensure compliance with FCC & CE standards.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device mat not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.
Important. Before proceeding, download the Installation and Operation Manual by visiting the website, www.aten.com and navigating to the product page. The manual includes important warnings, loading specifi cations and grounding instructions.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>