Thank you for purchasing a BN Thermic product. Manufactured to a high standard, this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
REGISTER: PLEASE REGISTER THIS PRODUCT ONLINE TO ACTIVATE YOUR GUARANTEE AT www.bnthermic.co.uk
IMPORTANT: PLEASE READ THESE INSTRUCTIONS, NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following:
You must check all electrical products, before use, to ensure that they are
safe. You must inspect power cables, plugs, sockets and any other connectors
for wear or damage. You must ensure that the risk of electric shock is
minimised by the installation of appropriate safety devices. A Residual
Current Circuit Breaker (RCCB) should be incorporated in the main distribution
board. If in any doubt consult a qualified electrician.
You must also read and understand the following instructions concerning electrical safety.
- The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
- Installation should always be carried out by a qualified electrician or a competent person in accordance with current electrical regulation.
- Ensure that the insulation of all the cables on the appliance is undamaged and safe, before connecting it to the power supply.
- Ensure that the cables are always protected against short circuit and overload.
- Regularly inspect the power supply cables and plugs etc. for wear or damage and check all connections to ensure that none are loose.
- Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that a correctly rated fuse is fitted.
- DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician.
- The unit should be protected by a suitably rated isolator and fuse or MCB.
- This heater is IP20 rated and is suitable for indoor or under cover use only.
- Do not attach this heater to an extension cord it must be hard wired in position.
GENERAL SAFETY INSTRUCTIONS
✓ Remove all packaging and store it away from children, check the package and
heater for visible damage or tampering.
✓ Familiarise yourself with the applications and limitations of the heater.
✓ Ensure the heater is in good order and condition both physically and
electrically before use. If in any doubt, do not use the unit and contact your
supplier.
✓ Only use recommended attachments and parts. To use unauthorised parts may be
dangerous and will invalidate your warranty.
✓ Keep tools and other items away from the heater when it is in use.
✓ Keep children and unauthorised persons away from the heater, as it gets hot.
✓ Disconnect from mains and allow to cool before attempting any cleaning or
maintenance.
✘ DO NOT use in areas where hazardous gasses or dusts may be present.
✘ DO NOT locate the heater directly below the power outlet.
✘ DO NOT disassemble the heater for any reason. This heater must be
checked by qualified personnel only.
✘ DO NOT use this heater to perform a task for which it has not been
designed.
❑ WARNING! This heater is not equipped with a built in device to control
the room temperature. Do not use this heater in a small room if it is occupied
by people not capable of leaving the room on their own, unless constant
supervision is provided.
❑ WARNING! Ensure you observe the safety distances and mounting heights
and there is no possibility of inflammable materials coming into contact.
INTRODUCTION & SPECIFICATION
This heater produces a totally dry heat, no condensation, no gas, no fumes. It reaches maximum heat output within a minute from being turned on. It is quick and easy to install reducing installation costs. Used with the CS-7 controller it can provide low / high heat or fan only settings.
Model | SCHG-30 |
---|---|
Power | 3000W |
Input supply | 220-240V |
Dimensions (W x D x H) | 594 x 594 x 153mm |
Weight | 9kg |
Recommended Mounting Height | 2.5 – 3.0M |
Safety Distance from Heater | 1.5M |
Optional Controller Model Number | CS-7 |
CS-7 Controller (Optional Extra)
MOUNTING INSTALLATION
CEILING MOUNTING
The heater is intended for installation in a suspended ceiling mounted within
or on the ‘tee’ bar supports. For optimum results do not fit in ceilings
higher than 3m. As air is only introduced through the front of the unit the
heater may be sighted anywhere. The air intake and discharge areas must be
kept completely clear for a minimum of 1.5m from the front of the heater. In
an area using multiple units, heaters should be spread to provide an even heat
distribution.
• IMPORTANT! A minimum clearance of 205mm is needed between the bottom of
the false ceiling and the original roof/ceiling to allow installation of the
heater.
• IMPORTANT! DO NOT use plastic type diffusers as these may be damaged by
the heat.
• IMPORTANT! Ensure that the mounting surface / ceiling supports are
capable of taking the additional weight of the heater there are 2 eye hooks
supplied with the heater that should be used if additional support of the
heater is required. When using the diffuser the four Z brackets provided
should be attached to the side of the heater to enable the heater to be
supported by the ‘tee’ bar and immediately above the diffuser.
ELECTRICAL CONNECTIONS
230V SINGLE PHASE – Without controls.
Please make sure you have read the Safety instructions and that you are a
suitably qualified electrician before continuing.
Drawings show connections inside the black terminal box on the outside of the
heater. Do NOT use power tools to undo or do up terminal screws.
Please Note:- Specified cable sizes are for typical installations,
correction factors may need to be used when determining actual cable sizes.
Standard Connection and Use
Use 1.5mm² 3 Core Mains Cable (see note above).
Connect Brown wire – Terminal 1 or L.
Connect Blue wire – Terminal 5 or N.
Connect Green / Yellow wire – Terminal E or
Ensure the 3 links are in position between terminals 1 and 2, 2 and 3, 3 and 4 as shown in drawing to the left.
PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE
230V SINGLE PHASE – With Thermostat (RST-TP)
Please make sure you have read the Safety instructions and that you are a
suitably qualified electrician before continuing. Drawings show connections
inside the black terminal box on the outside of the heater and the inside of
the RST-TP Thermostat. Other thermostats may be used BUT they must be suitable
for a 3kW load. Do NOT use power tools to undo or do up terminal screws.
Please Note:- Specified cable sizes are for typical installations, correction
factors may need to be used when determining actual cable sizes
Standard Connection using RST-TP Thermostat
Use 1.5mm² 3 Core Mains Cable (see note above) Use 1.5mm² 4 Core Cable to connect the heater to the thermostat (see note above).
Remove link in heater terminal box between terminals 1 and 2. Ensure the remaining 2 links are in position between terminals 2 and 3, 3 and 4 as shown in drawing to the left
Mains Cable
Connect Brown wire – Terminal 1 or L.
Connect Blue wire – Terminal 5 or N.
Connect Green / Yellow wire – Terminal E or
Heater to Thermostat Cable – (Colours for reference only)
Connect Brown wire – Terminal 1 or L of heater and Terminal 3 of Thermostat.
Connect Grey wire – Terminal 2 of heater and Terminal 1 of Thermostat.
Connect Blue wire – Terminal 5 or N of heater and Terminal 4 or N of
Thermostat.
Connect Green / Yellow wire – Terminal E or of the heater and earth connection
on Thermostat.
If you wish to de-rate the heater from 3kW to 2kW remove the link between terminal 3 and terminal 4. Ensure you tighten up the screws after removing the link.
PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE
230V SINGLE PHASE – With CS-7 Controller (CS-7 Controller provides on /
off / high heat / low heat / fan only settings)
Please make sure you have read the Safety instructions and that you are a
suitably qualified electrician before continuing.
Drawings show connections inside the black terminal box on the outside of the
heater and the inside of the CS-7 Controller.
Do NOT use power tools to undo or do up terminal screws.
Please Note:- Specified cable sizes are for typical installations, correction
factors may need to be used when determining actual cable sizes.
Standard Connection using CS-7 Controller
Use 1.5mm² 3 Core Mains Cable (see note above).
Use 1.5mm² 5 Core Cable to connect the heater to the CS-7 Controller (see note
above).
Remove any links that may be present in heater terminal box between terminals
1,2,3,4 or 5.
Mains Cable
Connect Brown wire – Terminal 1 or L.
Connect Blue wire – Terminal 5 or N.
Connect Green / Yellow wire – Terminal E or
Heater to CS-7 Controller Cable – (Colours for reference only)
Connect Brown wire – Terminal 1 or L of heater and Top Terminal L2 on right DP
Switch of CS-7.
Connect Grey wire – Terminal 2 of heater and Centre switch Terminal 1 of CS-7.
Connect Blue wire (adding red or another suitable colour sleeve to both ends
first) – Terminal 3 of heater and Terminal 1 on Left SP Switch of CS-7.
Connect Black wire – Terminal 4 of heater and Terminal 2 on left SP Switch of
CS-7.
Connect Green / Yellow wire – Terminal E or of heater and earth connection on
CS-7.
PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE
230V SINGLE PHASE – With CS-7 Controller and RST-TP Thermostat
Please make sure you have read the Safety instructions and that you are a
suitably qualified electrician before continuing.
Drawings show connections inside the black terminal box on the outside of the
heater and the inside of the CS-7 and RST-TP Thermostat
Controllers. Other thermostats may be used BUT they must be suitable for a 3kW
load. Do NOT use power tools to undo or do up terminal screws.
Please Note:- Specified cable sizes are for typical installations,
correction factors may need to be used when determining actual cable sizes.
Standard Connection using CS-7 Controller and Thermostat
Use 1.5mm² 3 Core Mains Cable (see note above).
Use 1.5mm² 6 Core Cable to connect the heater to the CS-7 Controller (see note
above).
Use 1.5mm² 4 Core Cable to connect the CS-7 Controller to Thermostat (see note
above).
Remove any links that may be present in heater terminal box between terminals
1,2,3,4 or 5.
Mains Cable
Connect Brown wire – Terminal 1 or L.
Connect Blue wire – Terminal 5 or N.
Connect Green / Yellow wire – Terminal E or
Heater to CS-7 Controller Cable – (Colours for reference only)
First remove the Brown link cable between L and COM on CS-7 and replace with a
link between L and 2 (shown above by dark brown wire)
Connect Brown wire – Terminal 1 or L of heater and Top Terminal L2 on right DP
Switch of CS-7.
Connect Grey wire – Terminal 2 of heater and Centre switch Terminal 1 of CS-7.
Connect Red wire – Terminal 3 of heater and Terminal 1 on Left SP Switch of
CS-7.
Connect Black wire – Terminal 4 of heater and Terminal 2 on Left SP Switch of
CS-7.
Connect Blue wire – Terminal 5 or N of heater and Top Terminal N2 on right DP
Switch of CS-7.
Connect Green / Yellow wire – Terminal E or of heater and earth connection on
CS-7.
CS-7 Controller to Thermostat Cable – (Colours for reference only)
Connect Brown wire – Bottom Terminal L1 on right DP Switch of CS-7 and
Terminal 3 of the Thermostat.
Connect Grey wire –Terminal 1 of middle switch of CS-7 and Terminal 1 of the
Thermostat.
Connect Blue wire – Bottom Terminal N1 on right DP Switch on CS-7 and Terminal
4 or N of the Thermostat.
Connect Green / Yellow wire – Terminal E or of CS-7 and earth connection of
the Thermostat.
PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE
MAINTENANCE
Note: Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply. The heaters are intended to operate for many years, problem free. All moving parts are factory lubricated and therefore should require no service. Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign materials. This is especially important immediately before the heating season. Any dust build up can be loosened using a brush and a vacuum cleaner applied to the airways to ensure completed removal of any dust. When the heater is first turned on after cleaning an unusual odour may be noted this is due to the dust particles which inevitably will be disturbed and will be burnt off from the heating element. If in any doubt always consult a qualified electrician for advice.
AUTO CUT OUT
This heater is fitted with a semi-automatic safety device to prevent overheating. The device will isolate the heating element while the fan continues to operate. Should this occur, disconnect the heater from the mains supply for a minimum of 5 minutes, check and remove any foreign materials around the airways. If the heater fails to operate or the safety cut out operates again, turn off the heater and contact a qualified electrician.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
WEEE REGULATIONS:
This appliance bears the symbol of the crossed waste bin. This indicates that,
at the end of its useful life, it must not be disposed of as domestic waste,
but must be taken to a collection centre for waste electrical and electronic
equipment. It is the user’s responsibility to dispose of this appliance
through the appropriate channels. Failure to do so may incur penalties
established by laws governing waste disposal.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Your BN Thermic product is guaranteed for one year from date of
purchase. We will repair or replace at our discretion any part found to be
defective. We cannot assume any consequential liability. This guarantee in no
way prejudices your rights under common law and is offered as an addition to
consumer liability rights.
REGISTER: Activate your warranty by registering online at
www.bnthermic.co.uk and retain this installation data for future reference.
Customer Support
BN Thermic Ltd,
34 Stephenson Way,
Crawley, RH10 1TN
Tel: +44 (0) 1293 547361
sales@bnthermic.co.uk
www.bnthermic.co.uk