RAVAK SRV2-S Supernova shower enclosure Instructions

June 5, 2024
RAVAK

RAVAK SRV2-S Supernova shower enclosure

RAVAK-SRV2-S-Supernova-shower-
enclosure-product

Models

| SRV2 – S – 75

+ SRV2 – S -75

| SRV2 – S – 80

+ SRV2 – S -80

| SRV2 – S – 90

+ SRV2 – S – 90

---|---|---|---
| (720-740)

x (720-740)

| (770-790)

x (770-790)

| (870-890)

x (870-890)

| 396| 431| 504
| SRV2 – S – 100

+ SRV2 – S – 100

| SRV2 – S – 75

+ SRV2 – S – 90

---|---|---
| (970-990)x(970-990)| (720-740)x(870-890)
| 530| 454
| ASRV3- 75

+ ASRV3-75

| ASRV3- 80

+ ASRV3-80

| ASRV3- 90

+ ASRV3-90

---|---|---|---
| (720-740)

x (720-740)

| (770-790)

x (770-790)

| (870-890)

x (870-890)

| 495| 543| 635
| ASRV3- 100

+ ASRV3-100

| ASRV3- 75

+ ASRV3-90

---|---|---
| (970-990)x(970-990)| (720-740)x(870-890)
| 670| 570

Contents of the assembly pack

  1. Plastic corner connection 1 pc.
  2. Dowel plugs 8 mm 3 pcs
  3. Screws 4/40 mm 3 pcs
  4. self-cutting screws 3,5/13 mm 2 pcs
  5. Self-cutting screws 3,5/6,5 mm 2 pcs
  6. Drill 2,6 mm 1 pc.
  7. Wall connecting profile 1 pc.
  8. Cover 2 pcs
  9. Coverwasher 2 pcs

ASSEMBLY INSTRUCTIONS

  1. The delivery consists of 2 pcs of part SRV – S width 750, 800, 900, or 1000 mm and 1 pc of fixed wall PSS(APSS) width 750, 800, 900, or 1000 mm (+ corner connection profile). Before assembly check the completeness of delivery.
  2. The assembly is done outside the shower tray. Position the plastic corner connections into the frame, drill the holes 2,6 mm and fix the connections using screws 3,5/6,5 mm.
  3. Sealing of the closed door is made by two magnetic profiles. If these magnetic profiles do not fit to each other, remove one of them gently using a screwdriver, turn it around and push it back again.
  4. Position the shower corner onto the shower tray, adjust the correct position and mark the holes on the wall.
  5. Remove the wall connecting profiles from the frame and mark the holes on the wall.
  6. Fix the wall connection profiles to the wall using screws 4/40 mm.
  7. Position the assembled shower corner onto the shower tray, slide it into the wall connecting profiles, and adjust and try the correct function of the door.
  8. Use the prepared holes of the wall connecting profiles and drill holes 2,6 mm into the frame of the shower corner. Secure it with screws 3,5/13 mm.
  9. Use silicone sealing compound. The seal between the tiles and the wall connects the profile on the inside and on the outside. Seal only on the outside of the lower running track. The a. m. the operation must be done by means of the silicone RAVAK PROFESSIONAL which has excellent cohesion. If another putty is used you run a risk it will not be water-resistant.
  10. Both shower tray and polystyrene glass are protected by thin plastic foil. Do not forget to remove it before using the enclosure.
  11. The assembly of the shower enclosure with the fixed wall.RAVAK-SRV2-S-Supernova-shower-enclosure-fig-1 RAVAK-SRV2-S-Supernova-shower-enclosure-fig-2 RAVAK-SRV2-S-Supernova-shower-enclosure-fig-3

The assembly of a shower corner combined with a fixed wall is similar to the assembly of the basic version. After the assembly of the shower enclosure, the fixed wall can be attached using the angle connecting profile. Remove one wall connection profile from the frame and slide the angle connecting profile instead of it. Slide the wall connecting profile onto the frame of the fixed wall. The two halves of the shower enclosure can be installed either right or left (turn upside down). The textured side of the glass faces outwards. Put the complete shower enclosure onto the shower tray, mark the position of the wall connecting profiles on the wall and mark the position of the frame inside the angle connecting the profile. Further assembly is done outside the tray. Remove the fixed wall, drill the holes into its frame and connect it together with an angle connecting profile using screws 3,5/13 mm. Further, follow the basic assembly instructions. Use the prepared holes of the wall connecting profiles and angle connecting profile and drill the holes 2,6 mm into the frame. Connect it screws 3,5/13 mm.

IMPORTANT INFORMATION

When maintaining the shower bath, only wipe the painted parts, glass, and plastic, using a fine cloth and normal household detergents. Never use abrasive pastes, solvents, acetones, or similar substances. The manufacturer is not responsible for damage caused by inappropriate use, installation, or maintenance of the product. The manufacturer is entitled to continuous innovation of the product. For all other information concerning the mounting, use, and maintenance, ask your salesperson. The guarantee is 24 months from the date of sale. The manufacturer recommends: RAVAK ANTI CALC CONDITIONER – is a preparation that perfectly renews and maintains all the qualities of the RAVAK ANTI CALC protective coating; RAVAK CLEANER – works to remove old and dried-on debris from glass surfaces, shower frames, enamel and acrylic bathtubs, washbasins and water taps; RAVAK DISINFECTANT – is a special preparation with considerable anti-bacterial and anti-fungal effects.

Contacts

RAVAK a.s.,

RAVAK SLOVAKIA spol. s r.o.

RAVAK POLSKA s.a.

  • Ka³êczyn 2B, , ul. Radziejowicka 124, 05-825 Grodzisk Mazowiecki, POLSKA
  • tel.: 22 / 755 40 30,
  • fax: 22 / 755 43 90,
  • e-mail: info@ravak.pl,
  • www.ravak.pl

RAVAK Hungary Kft.,

  • 1142 Budapest, Erzsébet királyné útja 125, HUNGARY
  • tel.: 06 (1) 223 13 15, 06 (1) 223 13 16,
  • fax: 06 (1) 223 13 14,
  • e-mail: info@ravak.hu,
  • www.ravak.hu

Ravak Gesellschaft

  • für Sanitärprodukte mbH, Alexanderstrasse 58, D – 45472 Mülheim an der Ruhr
  • Tel. (0208) 37789-30
  • Fax. (0208) 37789-55,
  • www.ravak.de,
  • e-mail: info@ravak.de

RAVAK a.s.

  • Representative Office in Ukraine, 21 Dniprovska Naberezhnaya str., 2nd floor, 02081, Kyiv, Ukraine
  • tel.: 00380 44 2203232, 00380 44 3605200,
  • fax: 00380 44 2204343,
  • e-mail: ravak@ravak.kiev.ua,
  • web: www.ravak.ua.

OOO RAVAK

  • ru, ul. Staropetrovskiy pr. 7A, Moskva 125 130,
  • tel./fax: 007 495 710 82 23, 007 495 450 12 77
  • e-mail: ravak@inbox.ru,
  • www.ravak.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals