EMPIRE VFD32FB0F-4 Deluxe Vent Free Universal Fireboxes Installation Guide
- July 8, 2024
- Empire
Table of Contents
- VFD32FB0F-4 Deluxe Vent Free Universal Fireboxes
- IMPORTANT SAFETY INFORMATION
- INTRODUCTION
- CLEARANCES
- FIREBOX INSTALLATION INSTRUCTIONS
- INSTALLING HOOD
- GAS LINE CONNECTION
- OPTIONAL FBB5 SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS
- JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
- MAINTENANCE
- PARTS LIST
- PARTS VIEW
- ACCESSORIES
- MASTER PARTS DISTRIBUTOR LIST
- HOW TO ORDER REPAIR PARTS
- WARRANTY
- Documents / Resources
EMPIRE VFD42FB2AL-4
Owner’s Manual
Shop genuine replacement parts for
EMPIRE
VFD42FB2AL-4
VFD32FB0F-4 Deluxe Vent Free Universal Fireboxes
This Owner’s Manual is provided and hosted by Appliance Factory
Parts.
Find Your EMPIRE Fireplace Parts – Select From 642
Models
——– Manual continues below ——–
INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL
DELUXE VENT – FREE UNIVERSAL FIREBOXES ANSI Z21.91
Ventless Fireplace Enclosures for Gas Fired Decorative Type Unvented Room
Heaters
INSTALLER:
WARNING
FIRE OR EXPLOSION HAZARD
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
Failure to follow safety warnings exactly could result in serious injury,
death or property damage.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
UNIVERSAL FIREBOX FOR ALL VENT FREE LOG SETS MODELS:
VFD32FB0F-4
VFD32FB0L-4
VFD32FB2AF-4
VFD32FB2AL-4
VFD32FB2MF-6
VFD32FB2ML-6| VFD36FB0F-4
VFD36FB0L-4
VFD36FB2AF-4
VFD36FB2AL-4
VFD36FB2MF-6
VFD36FB2ML-6
VFD36FB3MF-6| VFD42FB0F-4
VFD42FB0L-4
VFD42FB2AF-4
VFD42FB2AL-4
VFD42FB2MF-6
VFD42FB2ML-6
---|---|---
WARNING
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to this manual. For assistance or
additional information, consult a qualified installer, service agency or the
gas supplier.
FOR USE ONLY WITH A LISTED GAS-FIRED UNVENTED
DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H.
Do not build a wood fire.
Carefully review the instructions supplied with the decorative type unvented
room heater for the minimum fireplace size requirement.
Do not install A VENT-FREE LOG SET in this firebox, unless this firebox meets
the minimum dimensions required for the installation.
This appliance may be installed in an aftermarket, permanently located,
manufactured home (USA only) or mobile home, where not prohibited by local
codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases,
unless a certified kit is used.
Do not attempt to modify or alter the construction of the firebox or its
components. Any modification or alteration of construction may void the
warranty of this firebox. Children and adults should be alerted to the hazards
of high surface temperature and should stay away to avoid burns or clothing
ignition. Young children should be carefully supervised when they are in the
same room as the firebox.
We suggest that our gas hearth products be installed and serviced by profes- sionals who are certified in the U.S. by the National Fireplace Institute®* (NFI) as NFI Gas Specialists.
IMPORTANT SAFETY INFORMATION
The installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition) and to
the National electrical Code, ANSI/NFPA70 (latest edition).
NOTE: Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and at least annually by
a qualified service person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc. It is imperative that
control compartment, burners and circulating air passageways of the appliance
be kept clean.
Any safety screen or guard removed for servicing an appliance must be replaced
prior to operating the appliance. Provide adequate combustion and ventilation
air.
The flow of combustion and ventilation air MUST NOT be obstructed.
Provide adequate clearance around air openings into the combustion chamber and
adequate accessibility clearance for servicing and proper operation. NEVER
obstruct the front opening of the appliance.
This Empire Comfort Systems, Inc. firebox and its components have been tested
and will operate safely when installed in accordance with this installation
manual. Read all instructions before starting installation, then follow these
instructions carefully during
installation to maximize firebox benefit and safety. Report to your dealer any
parts damaged in shipment. The Empire Comfort Systems, Inc. warranty will be
voided by, and Empire Comfort Systems, Inc. disclaims any responsibility for
the following actions:
– Installation of any damaged firebox.
– Modification of the firebox or any of the components parts thereof.
– Installation other than as instructed by Empire Comfort Systems, Inc.
– Installation and/or use of any component part or accessory not approved by
Empire Comfort Systems, Inc. in combination or assembly with a Empire Comfort
Systems, Inc. firebox, not withstanding any independent testing laboratory or
other third party approval of such component part or accessory.
Any such action may create a possible fire hazard.
Consult your local building codes.
Firebox Screen.
The firebox screen must be in place when the firebox is operating.
INTRODUCTION
Instructions to Installer
- Installer must leave instruction manual with owner after installation.
- Installer must have owner fill out and mail warranty card supplied with firebox.
- Installer should show owner how to start and operate log set that is installed into firebox.
Important
All correspondence should refer to complete Model Number, Serial Number.
Notice: During initial firing of this firebox with a log set installed,
its paint will bake out, and smoke will occur. To prevent triggering of smoke
alarms, ventilate the room in which the unit is installed.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
accessories and repair and servicing of equipment shall be performed only by a
qualified agency. The term “qualified agency” means any individual, firm,
corporation or company which either in person or through a representative is
engaged in and is responsible for (a) the installation or replacement of gas
piping or (b) the connection, installation, repair or servicing of equipment,
who is experienced in such work, familiar with all precautions
required and has complied with all the requirements of the authority having
jurisdiction.
Commonwealth of Massachusetts: The installation must be made by a licensed
plumber or gas fitter in the Commonwealth of Massachusetts. The state of
Massachusetts requires that a flexible appliance connector cannot exceed three
feet in length.
Sellers of unvented propane or natural gas-fired supplemental room heaters
shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
In the Commonwealth of Massachusetts, unvented propane and natural gas-fired
space heaters shall be prohibited in bedrooms and bathrooms.
The installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.
CLEARANCES
Sidewall Clearances: The clearance from the inside of the firebox to
perpendicular combustible side wall should not be less than 6 inches. See
Figure 1. Firebox Side and Back Clearances: The firebox outer casing side
and back flanges are zero clearance to combustibles.
Top Framing and Finishing: Combustible finishing materials requires 3/4
inch to top of unit. See Figure 2.
Ceiling Clearances: The
ceiling height should not be less than 42 inches from the top of the hood. See
Figure 3.
Mantel Clearances: Vent free firebox models must use the hood supplied
with the firebox, or one of the optional hood kits available for each model.
If a combustible mantel is installed, it must meet the clearance requirements
detailed below.
Grate Clearance: The minimum clearance between the front legs of the
grate and front edge of the firebox is 2 inches.
Leave at least 36 inches clearance from the front of the firebox.
FIREBOX INSTALLATION INSTRUCTIONS
Any vent-free Gas Log Heater must be “For use with approved ANSI Z21.11.2
unvented room heater.”
Follow and complete the installation instructions of the gas log set and the
requirements of this firebox.
Check all fittings for leaks before lighting the gas log set.
In planning the installation for the firebox, it is necessary to determine
where the unit is to be installed and whether optional accessories are
desired. Gas supply piping should also be planned at this time.
A Gas Shut Off Must Be In This Line.
The firebox can be mounted on any of these surfaces:
- A flat hard combustible or non-combustible surface.
- A raised platform of combustible or non-combustible material.
- Recessed into the floor as illustrated by Figure 4 (flush face), and Figure 5 (louvered models).
- Supported under all four corners of the firebox so that contact is made on all four perimeter edges on the bottom of the unit (Example: Four concrete masonry blocks).
If the firebox is installed directly on carpeting, tile or other combustible material other than wood flooring, it should be installed on a metal or wood panel extending the full width and depth of the unit. Deluxe Vent-Free Firebox Framing Dimensions (in inches)
Attention: Add 3-3/4 inches to “A” Dimension when using flush mantel base.
Model | A | B | C |
---|---|---|---|
Framing Height | Framing Width | Framing Depth | |
VFD32FB | 33 3/4 | 35 1/2 | 16 1/4 |
VFD36FB | 35 3/4 | 40 1/2 | 18 3/4 |
VFD42FB | 35 3/4 | 44 1/2 | 18 3/4 |
At this point, you should have decided what components to include in your
installation, and where the firebox is to be located. If this has not been
done, stop and consult your dealer for assistance with this planning.
Planning Your Installation
Please note that the optional VFA2 Fresh Air kit available for use with the
Vent Free Firebox must be installed at the time of the initial installation.
Refer to pages 10, 11 and 12 for detailed instructions for the air kit.
Accessory kits such as the FBB5 Blower kit, Trim kits, Mantels, Full Cabinet
Mantels, plus other Decorative Frame, Hood, and Door accessory kits may be
installed after the firebox is secured to the framed opening.
Refer to the instructions provided with each of the optional accessory kits
for proper installation and operation.
Firebox Framing
Firebox framing can be built before or after the firebox is set in place.
Framing should be positioned to accommodate wall covering and firebox facing
material. The firebox framing should be constructed of 2 x 4 lumber or
heavier. The framing headers must be at least 3/4 inch above the fireplace.
Refer to Figures 6 and 7 for firebox framing dimensions. OUTER FIREBOX DIMENSIONS OUTER FIREBOX DIMENSIONS (in inches)
INDEX LETTER | LOUVERED | FLUSH |
---|---|---|
VFD32 | VFD36 | VFD42 |
A | 33 | 35 |
B | 35 | 40 |
C | 16 1/2 | 19 |
D | 27 7/8 | 31 7/8 |
F | 31 | 36 |
G | 22 1/4 | 24 1/4 |
H | 13/16 | 13/16 |
I | 31 1/2 | 33 1/2 |
J | 85/16 | 85/16 |
K | 4 3/4 | 4 3/4 |
L | 30 1/4 | 34 5/8 |
M | 60 3/8 | 69 1/8 |
N | 2 11/16 | 2 11/16 |
0 | 42 5/8 | 48 7/8 |
INNER FIREBOX DIMENSIONS (in inches)
INDEX LETTER | VFD32 | VFD36 | VFD42 |
---|
WITHOUT BRICK
A| 31| 36| 40
B| 25 3/16| 29 3/16| 33 3/16
C| 141/8| 161/2| 161/2
D| 18 11/16| 20| 20
E| 22| 24| 24
WITH BRICK
A| 29 5/16| 34 5/16| 38 5/16
B| 24| 28| 32
C| 13 5/16| 15 3/4| 15 3/4
D| 18 11/16| 20| 20
E| 22| 24| 24
Figure 7
Firebox Dimensions
Locating Firebox
Place firebox in framing opening. Use the tabs on the side of the firebox to
attach firebox to framing. Different tab locations can be used for finishing
materials with thicknesses of 1/2 inch and 5/8 inch.
See Figure 8.
Framing tabs should fit directly against framing material. Use at least one
nail per bracket to secure in place.
Check squareness of the firebox prior to securing to framed opening.
See Figure 9.
INSTALLING HOOD
A black hood that is furnished with each firebox (or optional hood) MUST be
installed before the firebox is used. Failure to do so may create a possible
fire hazard. The hood is located behind upper louver, or inside the firebox on
flush face units. If brass, stainless steel, or hammered pewter hoods are
desired, they can be purchased as an option. Attachment is the same as the
standard black hood.
Flush Face Models
- On flush face models, loosen the two screws (A) holding firebox top to face panel, then slide the hood flange between the firebox top and face panel and re-tighten the screws.
- Install one screw at each end of the hood as shown (C).
Louvered Models
- If you have a louvered model, remove upper louver.
- Place the top hood flange on top of the firebox, then install three screws through the firebox top from below and screw into the pilot holes in the hood flange (B).
- Install one screw at each end of the hood as shown (C).
- Re-install louver.
CAUTION: The hood must be installed prior to operation of appliance. See
Figure 10.
Flush Face Models Extended
Hoods
If your non-combustible facing material is over 1″ in thickness that will be
used to finish this firebox, an extended hood is available that will extend
out 2″ farther out into the room. Contact your local dealer for details.
VB4H32BL | Standard Black |
---|---|
VB4H36BL | Standard Black |
VB4H42BL | Standard Black |
Finishing
All joints (top, bottom and sides), where the wall or decorative facing
material meets the firebox surround should be sealed with a noncombustible
material.
Hearth extensions are recommended, but not required for these fireboxes.
GAS LINE CONNECTION
The firebox is designed to accept a 3/8-inch gas line for an approved vent-
free gas logset. Have the line installed by a qualified service person in
accordance with all building codes. Consult local building codes to properly
size the gas supply line leading to the 3/8-inch hook-up at the unit. The
state of Massachusetts requires that a flexible appliance connector cannot
exceed three feet in length.
Gas access holes are provided on both sides of the firebox. See Figure 11. On
models with refractory brick panels installed, carefully remove the knockout
in the refractory brick panel using a large standard screwdriver and hammer.
First, place screwdriver in groove next to plug and pry sideways to pop out
main plug. Then remove the remaining concrete in hole with gentle tapping with
ball peen hammer and/or screwdriver. A masonry drill and bit may also be used
to create a clean hole for the gas line to pass through. See Figure 12.
When installing optional ceramic fiber side panels into firebox, lay panel on
a flat surface. Remove the gas line knockout (round0 0depression) in the
appropriate side panel using a drill or utility knife. After the brick panel
knockout is removed, the firebox wrap may have a round metal knockout that
must be removed also. Use a screwdriver to punch out the metal knockout.0
Check gas type. Use only the gas type indicated on the gas log set rating
plate. If the gas listed on the plate is not your type of gas supply, DO NOT
INSTALL. Contact your dealer for proper model. Always use an external
regulator for all Propane fireboxes to reduce 00the supply tank pressure to a
maximum of 14 inch w.c. This is in0 addition to the regulator fitted to the
log set.
WARNING
Connection directly to an unregulated propane tank can cause explosion.
Install only a ANSI Z21.11.2 vent-free log set into this firebox. NOTE: When installing stainless
steel or reflective decorative liner kits, gas lines must come through the
bottom of the firebox. See Figure 11.
OPTIONAL FBB5 SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS
Attention: Install blower assembly before connecting gas inlet supply
line.
Wiring
The appliance, when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized.
This appliance is equipped with a three-prong [grounding] plug for your
protection against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug. For an ungrounded receptacle, an adapter, which has two prongs and
a wire for grounding, can be purchased, plugged into the ungrounded receptacle
and its wire connected to the receptacle mounting screw. With this wire
completing the ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors
can cause improper and dangerous operation. Verify proper operation after
servicing.
NOTE: Junction box on right side of firebox must be pre-wired at time of
firebox installation for use with blower assembly. A standard wall ON/OFF wall
switch or optional SCV1 Variable Speed Control Kit should be installed to
activate power to the Firebox, and control the operation of the FBB5 Blower
assembly.
It is recommended that installation of the wiring be performed by a qualified
electrician. See Figure 13.
-
If installed, turn OFF gas supply to firebox/gas log.
-
If applicable, turn OFF electric supply to firebox.
CAUTION
All wiring should be done by a qualified electrician and shall be in compliance with all local, city and state building codes. Before making the electrical connection, make sure that main power supply is disconnected. The appliance, when installed, must be electrically grounded in accordance with local codes, with the national electrical code ansi/nfpa 70 (latest edition).A factory installed junction box is located on the lower right side of the firebox. Wiring must be fed to the junction box and attached to the receptacle that is provided. From right side of the firebox, remove the screw securing the junction box assembly. Leave approximately 6 inches of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to opposite side of receptacle. The ground wire should be attached to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
Attention: If installed, do not damage gas inlet supply line when blower assembly is inserted into firebox. In some cases, removal the gas inlet supply line may be necessary. -
Determine which type of firebox you have prior to installation. See Figures 14 and 15.
-
Remove air deflector by removing the four screws securing it to the blower assembly.
-
Insert blower assembly into interior, bottom of firebox. Position blower assembly so that you align the notch on back of blower assembly with the center screw on firebox back, then push the blower assembly against firebox back. The blower wheel must be centered with the back wall of the firebox. The magnets on the back and bottom of blower assembly will sufficiently hold blower assembly in place.
-
Push tab away with standard screwdriver on upper right firebox.
-
Next, find the fan control switch and wire assembly. Feed the wires through the hole at the top of the firebox, and secure the fan control switch with two #6 screws provided. See Figure 17.
-
The fan control wires will slide down between the firebox and outer wrap near the blower assembly. See Figure 17.
-
One fan control wire will have a 1/4 inch female terminal that must be attached to the open terminal on the blower motor. See Figure 20, Connection A.
-
The other fan control wire has a 1/4 inch male terminal. Attach this terminal to the open terminal on the blower power cord. See Figure 20, Connection B.
-
Route the wires away from moving parts of the blower assembly and retain wires together near the blower motor using the plastic purse clip provided.
-
To complete the installation, plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap. See Figure 19.
-
If room permits, the power cord can be located from the outside of the unit looking through the junction box access hole (with the junction box removed), then plug up the power cord before reinstalling the pre-wired junction box.
-
Once all connections are made electrically, it is recommended that you test the blower fan control operation by turning on power to the blower (CAUTION: 110 Volt). Then apply heat to the fan control switch inside the firebox with a lighter or match until blower is activated. Once blower is activated, check for proper operation. Do not place hands near blower assembly or other wiring while power is on.
-
Replace blower access plate and/or reinstall the brick liner panels if provided.
-
This completes the installation of the optional FBB5 Blower kit accessory.
NOTE: This blower is equipped with a heat activated fan control switch.
Blower will operate when the firebox warms up, and will turn off automatically
when the firebox cools down. Blower
Motor
The blower motor does not have oiling holes. Do not attempt to oil the blower
motor.
Blower Wheels
The blower wheels will collect lint and could require periodic cleaning. If
the air output decreases or the noise level increases, it indicates a dirty
blower wheel. Remove fan and clean blower wheels.
WARNING
Unplugging of blower accessory will not stop the heater from cycling. To turn
off gas to the heater (millivolt model): push in gas control knob slightly and
turn clockwise to OFF. Do not force. To turn off gas on direct ignition model,
turn gas line valve to OFF.
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
CAUTION
All wiring should be done by a qualified electrician and shall be in
compliance with all local, city and state building codes. Before making the
electrical connection, make sure that main power supply is disconnected. The
appliance, when installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the national electrical
code ansi/nfpa 70 (latest edition)
A factory installed junction box is located on the lower right hand side of
the firebox. Wiring must be fed to the junction box and attached to the
receptacle that is provided. Remove the knockout in the installed junction box
to accept wiring into the junction box. Install a UL listed cable clamp (not
supplied) in the knockout hole. Leave approximately 6 inches of wire in the
junction box for connection.
Attach black wire to one side of the receptacle and white wire to opposite
side of receptacle. The ground wire should be attached to the green (neutral)
screw.
Install the receptacle into the junction box. Attach cover plate.
MAINTENANCE
Keep the control compartment, logs and burner area surrounding the logs clean
by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer to
lighting instructions located on the log set.
Never obstruct the flow of the combustion and ventilation air. Keep the front
of the firebox clear of all obstacles and materials.
Screens must be closed during operation.
PARTS LIST
INDEX NO.|
PART NUMBER
|
DESCRIPTION
---|---|---
VFD32
| VFD36|
VFD42
1| 17169| 18807| 17187| UPPER LOUVER
2| 17170| 18808| 17188| LOWER LOUVER
3| 39520| 39520| 39520| JUNCTION BOX ASSEMBLY
4| R3492| R3492| R3492| RECEPTACLE
5| R3491| R3491| R3491| COVER, JUNCTION BOX
6| 27338| 27338| 27338| BRACKET, TOP BRICK RETAINER (QUANTITY 2)
7| 19401| 19401| 19401| BRACKET, BOTTOM BRICK RETAINER (QUANTITY 2)
8| R10388| R10392| R10392| BRICK PANEL RIGHT – REFRACTORY BRICK
8| 31675| 31678| 31678| BRICK PANEL RIGHT – FIBER BRICK
9| R10386| R10390| R10394| BRICK PANEL BACK – REFRACTORY BRICK
9| 31676| 31679| 31680| BRICK PANEL BACK – FIBER BRICK
10| R10387| R10391| R10391| BRICK PANEL LEFT – REFRACTORY BRICK
10| 31674| 31677| 31677| BRICK PANEL LEFT – FIBER BRICK
11| 39517| 39518| 39519| HOOD
12| R7051| R7052| R7053| ROD, SCREEN (QUANTITY 2)
13| R8137| R8148| R8148| SCREEN CURTAIN (QUANTITY 2)
14| 39492| 39494| 39496| FACE ASSEMBLY – LOUVERED
15| 39479| 39484| 39489| FACE ASSEMBLY – FLUSH
16| 38973| 38973| 38973| BLOWER COVER PLATE
PARTS VIEW
ACCESSORIES
Accessory
| Description|
Model Numbers
---|---|---
Fan Kit ****| Designed to provide forced air flow.| FBB5
Variable Speed Control Kit| Wall mounted variable speed control for use with
FBB5 blower| SCV-1
Brick Liners| Deluxe Firebox| Contact dealer
for all available optional liner kits
Fresh Air Kit| Deluxe and Premium Fireboxes| VFA2
Frame Kits| 3-Piece Frame Kits Black, Stainless Steel or Hammered Pewter|
Contact dealer for all available optional frame kits
Standard Hood| Brass hood = BR
Stainless Steel = SS
Hammered Pewter = HP| Contact dealer for allavailable optional hood
accessories
Extended 4″ Hoods| Extended hoods that extend out 2″ farther than the standard
hoods, to accommodate thicker surround materials.
Available as optional kits in Brass, Hammered Pewter, and Stainless Steel
finishes.| Contact dealer for all avail- able optional hood acces- sories
---|---|---
Louvers| Styles include Slat, Mission, Arch, and Leaf Patterns. Available as
optional kits in Brass, Hammered Pewter, and Stainless Steel finishes.|
Contact dealer for all avail- able optional louver acces- sories
Bottom Trim Strip| Available as optional kits in Brass, Hammered Pewter, and
Stainless Steel finishes.| Contact dealer for all available optional trim
acces- sories
Decorative Door Kits| Available as optional kits in Brass, Hammered Pewter,
and Stainless Steel finishes.| Contact dealer for all available optional frame
kit ac- cessories
Decorative Frame Kits| Available as optional kits in Brass, Hammered Pewter,
and Stainless Steel finishes.| Contact dealer for all available optional
decorative door kit accessories
MASTER PARTS DISTRIBUTOR LIST
To Order Parts Under Warranty, please contact your local Empire dealer. See
the dealer locator at www.empirecomfort.com.
To provide warranty service, your dealer will need your name and address,
purchase date and serial number, and the nature of the problem with the unit.
To Order Parts After the Warranty Period, please contact your dealer or one of
the Master Parts Distributors listed below. This list changes from time to
time. For the current list, please click on the Master Parts button at
www.empirecomfort.com. Please note:
Master Parts Distributors are independent businesses that stock the most
commonly ordered Original Equipment repair parts for Heaters, Grills, and
Fireplaces manufactured by Empire Comfort Systems Inc.
Dey Distributing
1401 Willow Lake Boulevard
Vadnais Heights, MN 55101
Phone: 651-490-9191
Toll Free: 800-397-1339
Website: www.deydistributing.com
Parts: Heater, Hearth and Grills
F. W. Webb Company
200 Locust Street
Hartford, CT 06114
Phone: 860-722-2433
Toll Free: 800-243-9360
Fax: 860-293-0479
Toll Free Fax: 800-274-2004
Websites: www.fwwebb.com &
www.victormfg.com
Parts: Heater, Hearth and Grills
East Coast Energy Products
10 East Route 36
West Long Branch, NJ 07764
Phone: 732-870-8809
Toll Free: 800-755-8809
Fax: 732-870-8811
Website: www.eastcoastenergy.com
Parts: Heater, Hearth and Grills
HOW TO ORDER REPAIR PARTS
Parts Not Under Warranty
Parts can be ordered through your Service Person, Dealer, or a Master Parts
Distributor. See this page for the Master Parts Distributors list. For best
results, the service person or dealer should order parts through the
distributor. Parts can be shipped directly to the service person/dealer.
Warranty Parts
Warranty parts will need a proof of purchase and can be ordered by your
Service Person or Dealer. Proof of purchase is required for warranty parts.
All parts listed in the Parts List have a Part Number. When ordering parts,
first obtain the Model Number and Serial Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the
Description of each part from the following illustration and part list. Be
sure to give all this information . . .
Appliance Model Number …………………………
Part Description…………………..
Appliance Serial Number………………..
Part Number…………………………….
Type of Gas (Propane or Natural)………………
Do not order bolts, screws, washers or nuts. They are standard hardware items
and can be purchased at any local hardware store.
Shipments contingent upon strikes, fires and all causes beyond our control.
WARRANTY
Empire Comfort Systems Inc. warranties this hearth product to be free from
defects at the time of purchase and for the periods specified below. Hearth
products must be installed by a qualified technician and must be maintained
and operated safely, in accordance with the instructions in the owner’s
manual. This warranty applies to the original purchaser only and is not
transferable. All warranty repairs must be accomplished by a qualified gas
appliance technician.
Limited Lifetime Parts Warranty with a Five-Year Limited Labor Warranty –
Combustion Chamber and Heat Exchanger
If the combustion chamber or heat exchanger (see parts list) fails because of
defective workmanship or material, Empire will repair or replace at Empire’s
option.
Within five years from the date of purchase, Empire will pay reasonable labor
to have the defective part repaired or replaced at Empire’s option.
Limited Five-Year Parts & Labor Warranty — All Other Components
(Except Remote Controls, Thermostats, Accessories and Replacement Parts)
Should any part fail because of defective workmanship or material within five
years from the date of purchase, Empire will repair or replace at Empire’s
option.
Within five years from the date of purchase, Empire will pay reasonable labor
to have that defect repaired at Empire’s option.
Limited One-Year Parts Warranty — Remote Controls, Thermostats,
Accessories, and Parts
Should any remote control, thermostat, accessory, or other part fail because
of defective workmanship within one year from the date of purchase, Empire
will repair or replace at Empire’s option.
Duties Of The Owner
The appliance must be installed by a qualified installer and operated in
accordance with the instructions furnished with the appliance.
Abill of sale, cancelled check, or payment record should be kept to verify
purchase date and establish warranty period.
Ready access to the appliance for service.
What Is Not Covered
Damages that might result from the use, misuse, or improper installation of
this appliance.
Travel, diagnostic costs and freight charges on warranted parts to and from
the factory.
Claims that do not involve defective workmanship or materials.
Unauthorized service or parts replacements.
Removal and reinstallation cost.
Inoperable due to improper or lack of maintenance.
How To Get Service
To make a claim under this warranty, please have your receipt available and
contact your installing dealer. Provide the dealer with the model number,
serial number, type of gas, and purchase verification. The installing dealer
is responsible for providing service and will contact the factory to initiate
any warranted parts replacements. Empire will make replacement parts available
at the factory. Shipping expenses are not covered.
If, after contacting your Empire dealer, service received has not been
satisfactory, contact: Consumer Relations Department, Empire Comfort Systems
Inc., PO Box 529, Belleville, Illinois 62222, or send an e-mail to
info@empirecomfort.com with “Consumer
Relations” in the subject line.
Your Rights Under State Law
This warranty gives your specific legal rights, and you may also have other
rights, which vary from state to state.
Empire Comfort Systems Inc. Belleville, IL
If you have a general question
about our products, please e-mail us at
info@empirecomfort.com.
If you have a service or repair question, please contact your dealer.
www.empirecomfort.com
Documents / Resources
|
EMPIRE VFD32FB0F-4 Deluxe Vent Free Universal
Fireboxes
[pdf] Installation Guide
VFD32FB0F-4, VFD32FB0L-4, VFD32FB2AF-4, VFD36FB0F-4, VFD36FB0L-4,
VFD36FB2AF-4, VFD42FB0F-4, VFD42FB0L-4, VFD42FB2AF-4, VFD32FB2AL-4,
VFD32FB2MF-6, VFD32FB2ML-6, VFD36FB2AL-4, VFD36FB2MF-6, VFD36FB2ML-6,
VFD42FB2AL-4, VFD42FB2MF-6, VFD42FB2ML-6, VFD00FB3MF-4, VFD36FB3MF-6,
VFD32FB0F-4 Deluxe Vent Free Universal Fireboxes, VFD32FB0F-4, Deluxe Vent
Free Universal Fireboxes, Vent Free Universal Fireboxes, Free Universal
Fireboxes, Universal Fireboxes, Fireboxes
---|---
|
EMPIRE VFD32FB0F-4 Deluxe Vent Free Universal
Fireboxes
[pdf] Installation Guide
VFD32FB0F-4 Deluxe Vent Free Universal Fireboxes, VFD32FB0F-4, Deluxe Vent
Free Universal Fireboxes, Free Universal Fireboxes, Universal Fireboxes,
Fireboxes
|
EMPIRE VFD32FB0F-4 Deluxe Vent Free Universal
Fireboxes
[pdf] Installation Guide
VFD32FB0F-4 Deluxe Vent Free Universal Fireboxes, VFD32FB0F-4, Deluxe Vent
Free Universal Fireboxes, Free Universal Fireboxes, Universal Fireboxes,
Fireboxes
|
EMPIRE VFD32FB0F-4 Deluxe Vent Free Universal
Fireboxes
[pdf] Installation Guide
VFD32FB0F-4 Deluxe Vent Free Universal Fireboxes, VFD32FB0F-4, Deluxe Vent
Free Universal Fireboxes, Free Universal Fireboxes, Universal Fireboxes,
Fireboxes
References
- Home - Empire Comfort Systems
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Empire Fireplace Parts - Select From 642 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>