INSTALLATION MANUAL
SUPPLEMENT FOR HMFATV-1
TOOLS/SUPPLIES REQUIRED FOR HMFATV
INSTALLATION
- Electric Drill
- Step Drill Bit (for VFLB(36,48,60,72)-1 only)
- 3/16″ Drill Bit
- 1-1/2″ Hole Saw
- Phillips Screw Driver
- 5/16″ Nut Driver
- Wall Anchors with #8 Screws (2)
- Wire Nuts (2)
HMFATV INTRODUCTION
The HMFATV Television Kit is designed to automate the operation of the HMFA
Forced Air Blower, in order to protect a wall-mounted television from heat
damage while the fireplace is in use. During normal operation, the blower is
turned on and off by a snap disc inside the firebox. In the case of a power
outage or blower failure, the fireplace will be deactivated by a wall-mounted
limit switch in order to protect the television. The rheostat control included
in the HMFA Forced Air Blower is not utilized.
FOR VFLB(36,48,60,72)FP(30,90)(N, P)-1, you must update the fireplace to work
with the HMFATV Television Kit by following these instructions. Afterward,
follow the 42929 Installation Instructions included with the HMFA Forced Air
Kit to complete the installation.
FOR VFLB(36,48,60,72)FP(30,90)(N, P)-2, disregard the steps below and follow
the 42929 Installation Instructions included with the HMFA Forced Air Kit to
complete the installation.
TOOLS REQUIRED TO UPDATE FIREPLACE
- Phillips Screwdriver
- Electric Drill
- Step Drill Bit (for 5/8” hole)
INSTALLATION
- Remove Screen Frame Assembly.
- Remove screws from the leading edge of the Firebox Top.
- Remove Firebox Top.
- For VFLB(36,48)-1, drill one 5/8″ hole on Firebox Back Wall as shown in Figure 1. For VFLB(60,72)-1, drill two 5/8″ holes on Firebox Outer Top as shown in Figure 2.
- Follow the 42929 Installation Instructions included with the HMFA Forced Air Kit to complete the installation.
HMFATV-1 PARTS LIST
Index Number| Part Number| Description| Quantity
N/S| N/A| Nut, 10-24| 2
N/S| N/A| Screw, 10-24 X 3/4″| 2
N/S| N/A| Screw, 4-40 X 3/4″| 2
N/S| N/A| Nut, 4-40| 2
1| R1148| Zip Tie| 4
2| R1569| Wire Clip| 2
3| 42862| Limit Switch Plate| 1
4| R11243| Cover Plate, Plain| 1
5| R1536| Wire Bushing, 5/8″| 2
6| R13268| Limit Switch, 150 Degree| 1
7| R6176| Switch, Fan Control| 1
8| R13269| Wire Harness, Switch On| 1
9| R13270| Wire Harness, Limit, Off| 1
10| R3490| Junction Box| 1
11| R7571| Connector, 3/8″ Romex| 2
N/S = Not Shown, N/A = Not Applicable
Empire Comfort Systems Inc. Belleville, IL
If you have a general question about our products, please e-mail us at
info@empirecomfort.com.
If you have a service or repair question, please contact your dealer.