ALL LED 12-24V Intelligent LED Strip Controller Installation Guide

June 28, 2024
ALL LED

12-24V Intelligent LED Strip Controller

“`html

Product Specifications

  • Model: AiQ/STRIP/REC
  • Input Voltage: 12-24VDC
  • Power: (48-96W)x5CH, 4Ax5CH
  • Operating Temperature: 12-24VDC
  • Efficiency: 99%
  • Power Consumption: 0.24W
  • Safety Rating: III
  • Material: White Polymer
  • IP Rating: IP20
  • Operation: Constant Voltage

Installation Guide

PLEASE READ BEFORE USE!

AiQ/STRIP/REC Smart-S – LED Strip
Controller

(Single Colour, Trilogy – CCT, RGB,
RGBWW+CW)

Pairing Instructions:

Initial programming of the system can be done as follows:

  1. Fusebox Lighting Breaker OFF for 5 Seconds, then ON.
  2. Say Alexa, add a device or search on relevant app.
  3. After successful addition to the network, a 3-minute window
    opens for find and bind (for remotes).

Network Pairing Mode:

This mode will automatically happen when the product is first
switched on. It allows connection to a network hub/gateway.

Find and Bind Pairing Mode (Remote Control):

If using a smart device, pair the module and remote to the hub
PRIOR to pairing with any remote control. For direct use with a
remote, follow the instructions provided.

Factory Reset:

To reset, toggle the power 7 times or push the program button on
the module 7 times. This will remove all paired connections to the
module.

Dimensions

Dip Switch Settings

Contact Information

ALL LED LTD

42 Sedgwick Road, Luton, LU4 9DT

www.allledgroup.com

Email: sales@allledgroup.com

Tel: +44 (0)208 841 9000

Returns & Faulty Items

Environmental Protection: Waste electrical products should not
be disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for
recycling advice.

The manufacturer will not be held liable for damages caused by
faults, defects, misuse, or incorrect installation. Your statutory
rights are not affected.

Frequently Asked Questions (FAQ)

Q: How do I reset the device to factory settings?

A: To perform a factory reset, toggle the power 7 times or push
the program button on the module 7 times. This will remove all
paired connections to the module.

Q: How do I pair the device with a remote control?

A: Follow the pairing instructions provided in the manual. Make
sure to pair the module and remote to the hub before pairing with
any remote control.

“`

Returns & Faulty Items
· If any problem is encountered during or after installation, please call the All LED technical department to get the problem resolved as soon as possible.
· Please do not just return the item to the outlet you purchased it from, as you are only entitled to a replacement or refund after the unit has undergone testing and the unit has been confirmed as having a manufacturing defect/fault. Your statutory rights are not affected.
· The manufacturer will not be deemed liable or held responsible for any damages caused by faults or manufacturing defects that may be present in any of its products or the misuse or incorrect installation of this device. Please refer to our troubleshooting guide for further information.
· All goods are supplied under the terms and conditions of All LED LTD, a copy of which may be obtained upon written request.

Environmental Protection Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice

The manufacturer will not be deemed liable or held responsible for any damages caused by faults or manufacturing defects that may be present in any of its products
or the misuse or incorrect installation of this device Your statutory rights are not affected.

ALL LED LTD 42 Sedgwick Road,
Luton, LU4 9DT
www.allledgroup.com sales@allledgroup.com Tel: +44 (0)208 841 9000

INSTALLATION GUIDE

!
PLEASE READ BEFORE USE!

AiQ/STRIP/REC Smart-S – LED Strip Controller
(Single Colour, Trilogy – CCT, RGB, RGBWW+CW)

Technical Specifications
Product Code Operating Voltage (V) Max Output Power (W) Output Current (Max) Output Voltage (Max) Efficiency % Network Standby Power (W) Class Body Material Ingress Protection Ambient Operating Temperature (°C) Guarantee Output type

AiQ/STRIP/REC 12-24VDC
(48-96W)x5CH 4Ax5CH 12-24VDC 99% 0.24W III
White Polymer IP20
-20°C ~ +50°C 5 Years
Constant Voltage

1

Pairing Instructions:
Initial programming of an entire system can be done as simply as: Fusebox Lighting Breaker OFF (5 Seconds), then ON. Say “Alexa, add a device” or search on relevant app. After the device has been added to a network successfully, a 3 minute window will open for find and bind (for remotes) Network Mode: 60 Seconds Find and Bind (for remotes): 3 Minutes
If the 1 minute window elapses, simply switch the module on and off. It will enter network pairing mode again.
Network Pairing Mode: This will automatically happen when the product is first switched on. This mode enables the user to connect the smart module to a network hub/gateway. This mode will last 1 minute or until a connection has been established. If successful, the lights will flash. Once the time limit has elapsed, the module will go into a normal state, with a 3 minute window to pair any remotes. Once added to a network, the module must be factory reset if the network must be changed.
Find and Bind Pairing Mode (Remote Control): Note: If using the items on a smart device, you MUST pair the module and remote to the hub PRIOR to pairing with any remote control. if using the module directly with a remote, you may proceed as below.
To set to this mode, toggle the power (Care Note on Discharge Timings) 4 times From ON – OFF>ON>OFF>ON>OFF>ON>OFF>ON Or push the program button on the module 4 times. The pairing mode enables the user to connect or to disconnect from a remote device such as a handheld remote. The mode will last 3 minutes. If successful, the lights will flash.
Factory Reset: To set to this mode, toggle the power (Care Note on Discharge Timings) 7 times From ON – OFF>ON>OFF>ON>OFF>ON>OFF>ON>OFF>ON>OFF>ON>OFF>ON Or push the program button on the module 7 times. Factory reset mode will remove all paired connections to the module. If successful, the lights will flash. After the reset has completed the module automatically goes into network pairing mode.

Dimensions
General Information
· Interference may occur with other products on the same frequency of 2.4Ghz · Product may differ in colour from image on box · Range signal can be reduced when using within materials such as concrete & metal