FOAMit FI-BP-25N Battery Powered Foam Unit Instruction Manual

June 27, 2024
FOAMit

FOAMit FI-BP-25N Battery Powered Foam Unit

Scan this code for operation manual

Safety

WARNING PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!

  • Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.

  • Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.

  • Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled
    or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.

  • Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death.

  • Always depressurize and clean the unit after each use. Never leave the unit unattended while pressurized.

  • Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury or death. DO NOT use a solution with a temperature above 100°F (37.8°C).

  • Some components may be hot during and after use. Use caution when servicing or handling the equipment.

  • Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.

  • Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. Never use hydrocarbons or flammable products with the unit.

  • Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to an alkaline.

  • Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.

  • Keep battery box lid closed and latched at all times unless accessing battery. Do not use with lid open or damaged. Do not expose unit to liquids, cleaning solutions, foam, or rain. The battery pack is not waterproof. Do not submerge in liquid. If battery pack gets wet, allow to dry before further use.

  • Using the unit with unapproved devices may result in a risk of fire, shock or personal injury. Only use with 24V Equip Series compatible equipment.

  • When not in use, store unit indoors in a cool, dry location. Keep unit away from unauthorized users. To prevent premature battery failure, do not store battery in a depleted state for long periods of time.

First Aid Instructions

  • Failure to follow first aid instructions may result in death or serious personal injury.
  • If battery liquid comes in contact with skin, wash immediately with soap and water, then neutralize with lemon juice or vinegar.
  • If battery liquid gets in your eyes, flush with clean water for a minimum of 10 minutes, then seek immediate medical attention.
  • If battery liquid is swallowed, seek immediate medical attention.

State of California Proposition 65 Warning
The battery can expose you to chemicals, including cobalt, lithium, manganese, nickel, oxide, and carbon black, which are known to the State of California to cause cancer and reproductive harm. For additional information, go to www.P65Warnings.ca.gov.

NOTICE
Refer to the separate manuals supplied with the battery and charger for additional safety precautions and instructions.
Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.

Protect the Environment
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations

Product Overview

Requirements
Liquid temperature range 40-100˚F (4.4-37.8˚C)
Electrical requirements 120-240 VAC at 50-60 Hz, 3A (GFCI protected outlet)

for battery charger only
Operating voltage| 24 VDC

Chemical compatibility

| Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact our customer service department.

Specifications
Power type Lithium-ion battery
Battery charge time 1 hour 10 minutes
Battery run time Up to 45 minutes of continuous use
Chemical pickup type Draws from pre-mixed solution
Number of products unit can draw from One product
Suction line diameter ⅜ in. (9.5 mm) inside diameter
Capacity 25 gallons (94.6 liters)
Discharge line length/diameter 12 ft. (3.7 m) hose, with 3/8 in. (9.5 mm)

inside diameter
Discharge wand/tip type| Polypropylene spray gun with 80° fan tip Stainless steel ball valve (SSBV) with 80° fan tip
Output distance| Up to 5 ft. (1.5 m)
Output volume| 4.9 gal/min (18.5 l/min)
Flow rate*| 0.5 gal/min (1.9 l/min)
Pump seals| Santoprene diaphragm, Viton check seals
Wheel type| Two 10 inch (25.4 cm) non-marking wheels and two 3 inch (7.6 cm) locking casters, one with lock

*Flow rates given are based on chemical with viscosity of water.

Product Components

Get to know the FI-BP-25N components that you will need to use, adjust or assemble.
Back plate assembly • Inside view

  1. In-line strainer
  2. Electric fluid pump
  3. Relay controller
  4. Check valve
  5. Needle valve
  6. Muffler
  7. Pressure switch
  8. Back plate thumb nuts
  9. Electric air compressor
  10. Suction line valve

Tank Assembly

11. Solution tank
12. Hinged lid
13. Drain plug
14. Discharge wand
15. Trigger gun
16. Discharge hose
17. Power button
18. Needle valve
19. Battery
20. Battery box
21. Suction line valve

Operating Instructions

  1. Remove battery and charger from packaging.
    Battery must be fully charged before use. Refer to charge level indicator table in battery user manual for more information.

  2. Once fully charged, insert battery into the receiver until properly secure. Close lid and secure the latch.
    Note : Keep battery box lid closed and latched unless accessing battery. Do not operate unit with lid open or damaged.

  3. Verify drain plug is securely closed.

  4. Following all instructions from chemical manufacturer, fill the solution tank with pre- mixed solution.

  5. Verify suction line valve at the base of the suction line is open, allowing fluid into the suction line.

  6. Press the power button to turn on the unit.

  7. Slowly open the discharge ball valve or squeeze trigger handle to begin foaming.

  8. While the unit is running and discharging product, adjust the needle valve to regulate the wetness or dryness of the foam following the steps below:
    a. Close needle valve completely in clockwise direction.
    b. Open needle valve in counter-clockwise direction 3 complete turns.
    c. Continue to open needle valve in ¼ turn increments, allowing 30 seconds between adjustments, until desired consistency of foam is achieved.

  9. Close the discharge ball valve, or release trigger handle to stop foaming.
    After Use Instructions
    Note : For proper handling and disposal procedures refer to chemical SDS.

  10. Solution should be removed from unit after each use.
    This can be done in two ways:
    a. Unthread drain plug from front of tank and drain solution into an approved location.
    b. Place discharge wand into approved container.
    Turn the needle valve to the wet setting and activate unit until all solution has been flushed from the unit.

  11. Press power button to turn off unit. Open the discharge ball valve or trigger handle to relieve remaining pressure.

  12. Before using unit with another chemistry, thoroughly flush with water.

Maintenance

WARNING
Performing any maintenance with the unit pressurized, may result in serious injury or death. Always ensure that the unit has been depressurized, before conducting any maintenance. Servicing or modifying unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.

Maintaining Your Unit
To keep your unit operating properly, periodically perform the following maintenance procedures:

  • Inspect the pump for wear and leaks.
  • Inspect all hoses for leaks or excessive wear. Verify all hose clamps are in good condition and properly secured.
  • Check the suction line and strainer for debris. Clean as needed.
  • If foam quality beings to decrease, inspect the wadding. Replace as needed.
  • Store battery in a half-charged state and maintain battery every 3-6 months.

Servicing Your Unit
To service your unit, refer to the service manual which includes:

  • Troubleshooting procedures.
  • Detailed parts breakdowns and illustrations.
  • Part numbers of serviceable components and assemblies.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals