**WARNING
**
Read this manual completely and understand the machine before operating or servicing it.
- Read all instructions before installing or operating unit.
- Always wear appropriate personal protective equipment (PPE) when operating or servicing unit.
- Follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS).
- Do not exceed an incoming air pressure of 100 psi (7 bar).
- Do not exceed a fluid temperature of 100˚F (37˚C).
- Only use clean and dry air. Air must be filtered and free of moisture or pump life will be diminished. If needed, install an air dryer before unit.
- Do not use air lubricator before the unit.
Specifications
Liquid Temperature: 40˚F to 100˚F (4.4˚C to 37˚C)
Droplet size: 20 microns at 50 ps
- liter of solution will cover approximately 1000 cubic feet (up to
system max of 38,000 cubic feet).*
A full tank of solution will supply the unit for approximately 1.5 hours.*
*NOTE: Area covered and run time may vary based on humidity, air flow, and product used.
Dimensions and Weight
- Length: 19 in (482 mm) approximately
- Width: 16 in (406 mm) approximately
- Height: 42 in (1066 mm) approximately
- Weight (empty): 31 lbs (14 kg ) approximately
Requirements
Air pressure required: 50 psi (3.4 bar) Air volume required: 7 CFM at 50 psi
(198.3 l/min at 3.4 bar)
Chemical Requirements: Follow all instructions from chemical manufacturer and Safety Data Sheet (SDS).
Air Operated Double Diaphragm Pump Models Offered:
- P56: Polypropylene body with Santoprene diaphragm
- P56V: Polypropylene body with Viton diaphragm
- P56K: Polypropylene body with Kalrez diaphragm
Operation Instructions
Wearing all PPE and observing all safety precautions dictated by the SDS for your product
- Fill the tank with the desired amount of product.
- Place the unit in the area to be misted.
- Ensure the air supply valve (BVB14) is in the closed position, and connect a compressed air line to the air inlet fitting (AP25).
- Open the air supply valve (BVB14) to activate the unit.
- Evacuate the area.
- After the unit has stopped misting, observe all appropriate safety precautions before reentering area. Close the air supply valve (BVB14) and disconnect the compressed air line from the unit.
TANK ASSEMBLY
ITEM NUMBER: TANK-10N-A
OPTIONAL COMPONENTS
AIR HOSE ASSEMBLY
- ITEM NUMBER: AH30
WATER SEPARATOR
- ITEM NUMBER: WS-20CFM
Plate – Inside View
Plate – Back View
MIST NOZZLE ASSEMBLY
COMPANY OTHER PRODUCT
ITEM NUMBER | DESCRIPTION |
---|---|
AG100 | 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE |
AH30 | 30 FT. AIR HOSE WITH QUICK CONNECT FITTINGS |
AP25 | PLUG 1/4 NPTM AIR FITTING – BRASS |
AS1-VS | 1/4-20 X 1/2 PHIL TRUSS MACH SCREW 19-8 W/516 ORANGE VIBRASEAL PATCH |
B103234 | 10-32 X 3/4 PHIL TRUSS MACH SCR 18-8 |
B8X58 | 8-15 X 5/8 inch PHIL FLAT TY-A 316 S.S. |
BEL14M14M | BRASS ELBOW 1/4in MPT X 1/4in MPT |
BPS-58SO | Back Panel Screw – 5/8 inch with Stand Off |
BPS-SSR | 1/4 INCH PUSHNUT BOLT RETAINER STAINLESS STEEL |
BVB14 | AIR INLET VALVE – VA BRS 025-4F4F-BT, NICKEL |
COT | 1/8 X 1 COTTER PIN 18-8 S/S |
DFP7 | 7 INCH HINGED CAP ASSEMBLY – INCLUDES BLACK CAP, LID FLANGE AND HINGE |
PIN
DFP7-C| 7 INCH FILL CAP POLYPRO BLACK
DFP7-F| 7 INCH TANK LID FLANGE POLYPRO
DFP7-PIN| HINGE PIN FOR DFP7-C & DFP7-C
DFP7-C-BL| 7 INCH FILL CAP POLYPRO BLUE PANTONE
DFP7-C-GN| 7 INCH FILL CAP POLYPRO GREEN PANTONE
DFP7-C-RD| 7 INCH FILL CAP POLYPRO RED PANTONE
DFP7-C-YL| 7 INCH FILL CAP POLYPRO YELLOW PANTONE
DP-A| DRAIN PLUG ASSEMBLY FOR TANK-10N TANK-20N
DP| FRONT DRAIN PLUG FOR PORTABLE UNIT POLYPRO
DP-G| FKM SQUARE CUT DRAIN PLUG GASKET
EC14-2| OETIKER CLAMP 13.8
EL14M14F| 1/4 FEM PIPE X 1/4 M PIPE ELBOW
FG-10N-2-BRKT| BRACKET FOR FG-10N-2
FMS1034| 10 X 3/4in PHIL SHEET METAL SS SCREW
FWAX15| FLAT AXLE WASHER
FWLG14| .569 ID X 1.28 OD X .08 THICK FLAT WASHER SS 18-8
H38B-H| 3/8 inch BLUE HOSE – Available per ft.
H38CP| 3/8IN OD POLYETHYLENE TUBING – NATURAL
HBSSEL1438| STAINLESS HOSE BARB ELBOW 1/4 INCH NPT X 3/8 HOSE BARB
HBSSEL1814| 304 STAINLESS ELBOW 1/8 INCH NPT X 1/4 INCH HOSE BARB
HHPB3414| HEX HEAD POLY REDUCER BUSHING 3/4 X 1/4
P56| 5700 PUMP WITH SANTOPRENE SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND
AIR PORT
P56K| 5700 PUMP WITH KALREZ SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR
PORT
P56V| 5700 PUMP WITH VITON SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR
PORT
20756103B| Polypro G57 Air Port x HB Straight, w/ Viton o-ring
HB14P| 1/4in BRASS HB AIR FITTING /G57/P56
HB5638| HOSE BARB FOR P56 PUMP
HB5638K| HOSE BARB FOR P56K PUMP
HB5638V| HOSE BARB FOR P56V PUMP
PFN-N130| PNEUMATIC FOG NOZZLE – POLYPROPYLENE AND KYNAR TIP – 3.7 GAL/HR PER
NOZZLE
PLPF-B| BLANK PORTABLE FOAMER PLATE WITH HINGE W/O HOLES
PLPF-PIN| 302 STAINLESS PORTABLE PLATE HINGE PIN
PVCV34FM| PVC VALVE 3/4in FPT X 3/4in MPT
QF1438| MALE CON. 3/8in TUBE X 1/4in MPT – POLYPROPYLENE
QF5638| 3/8in QF PUMP FITTING / G57
QFBH38| BULKHEAD 3/8in TUBE POLYPROPYLENE
QFEL1438| FIXED ELBOW 3/8in TUBE X 1/4in MPT POLYPROPYLENE
QFSEL38| PLUG-IN ELBOW 3/8in TUBE X 3/8in POLYPROPYLENE
QFT38| UNION TEE 3/8in TUBE POLYPROPYLENE
R14| 1/4 NPTF REGULATOR W/ FILTER-NO GAUGE
SSA14| SS304 MALE/FEMALE ADAPTOR 1/4 NPT X 1/4 NPT
SSAXLE14| 14 ½” long with the 5/8” diameter bar & 2 through holes with
countersinks beveled ends
SSC38| WORM GEAR CLAMP, S/S (.25-.63)
SSP12| STAINLESS STEEL AXLE PLATE – 2.5 inch X 1 inch – 2 HOLE
STR38-IL| IN LINE STRAINER 3/8 BARB 20 MESH 304 STAINLESS EDPM GSKT
TANK-10N| 10 GALLON NATURAL TANK
TW916| 1/2 INT TOOTH L/W 410SS
W15| NONMARKING WHEEL FOR PORTABLE UNITS
WS-20CFM| TSUNAMI WATER SEPARATOR 20 CFM
TIMER ADJUSTMENT INSTRUCTIONS
The TR120MF is a multifunction timer.
- The four switches in the top left (Function) control the timer mode. For fogging/misting applications, switches A, C, and D should be ON, and switch B should be OFF. This puts the timer in Dual Mode.
- The six switches in the bottom left (Time Base) control the time interval. The timer is factory set to MINUTES. To change the Time Base to seconds or hours, refer to the chart below.
- The five switches in the top right (Dual Mode t1) control the delay time.
- The five switches in the the bottom right (Dual Mode t2) control the run time. The active time for each function is equal to the combined values of any switch(es) that are ON.
NOTICE: the timer is factory set at 2 minute delay, 8 minute run time
-
FUNCTION (A to D)
This setting puts the time in Dual Mode -
TIME BASE (E to K)
Switches E, F, and G control t1. Switches H, J, and K control t2. -
DUAL MODE (t1)
These switches control the delay time -
DUAL MODE (t2)
These switches control the run time.
Timer Setting Example
In this example, the delay time has been set to 5 minutes, and the run time has been set to 20 minutes.
- The FUNCTION is set to Dual Mode.
- The TIME BASE is set to minutes.
- The total DELAY time is 5 (1+4=5)
- The total RUN time is 20 (4+16=20)
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.
Always remember to recycle.
*Specifications and parts are subject to change without notice.