Safety
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
First Aid Instructions:
- Failure to follow first aid instructions may result in death or serious personal injury.
- If battery liquid comes in contact with skin, wash immediately with soap and water, then neutralize with lemon juice or vinegar.
- If battery liquid gets in your eyes, flush with clean water for a minimum of 10 minutes, then seek immediate medical attention.
- If battery liquid is swallowed, seek immediate medical attention.
State of California Proposition 65 Warning:
• The battery can expose you to chemicals, including cobalt, lithium,
manganese, nickel, oxide, and carbon black, which are known to the State of
California to cause cancer and reproductive harm. For additional information,
go to www.P65Warnings.ca.gov.
NOTICE
Refer to the separate manuals supplied with the battery and charger for
additional safety precautions and instructions.
Servicing or modifying this unit with parts not listed in this manual may
cause the unit to operate improperly. Do not use unauthorized parts when
servicing the unit.
Protect the Environment
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations
Product Overview
Requirements
Specifications
*Flow rates given are based on chemical with viscosity of water.
Product Components
Get to know the FI-BP-20N components that you will need to use, adjust or assemble.
Back plate assembly • Inside view
Tank Assembly
Using your unit
Operating Instructions
-
Remove battery and charger from packaging. Ensure battery is fully charged. Refer to charge level indicator table in battery manual for more information.
-
Once fully charged, insert battery into the receiver until properly secure. Close lid and secure the latch.
NOTE: Keep battery box lid closed and latched unless accessing battery. Do not operate unit with lid open or damaged. -
Verify drain plug is securely closed.
-
Following all instructions from chemical manufacturer, fill the solution tank with pre- mixed solution.
-
Verify suction line valve at the base of the suction line is open, allowing fluid into the suction line.
-
Press the power button to turn on the unit.
-
Slowly open the discharge ball valve or squeeze trigger handle to begin foaming.
-
While the unit is running and discharging product, adjust the needle valve to regulate the wetness or dryness of the foam following the steps below:
a. Close needle valve completely in clockwise direction.
b. Open needle valve in counter-clockwise direction
3 complete turns.
c. Continue to open needle valve in ¼ turn increments, allowing 30 seconds between adjustments, until desired consistency of foam is achieved. -
Close the discharge ball valve, or release trigger handle to stop foaming.
After Use Instructions
NOTE: For proper handling and disposal procedures refer to chemical SDS.
10. Solution should be removed from unit after each use.
This can be done in two ways:
a. Unthread drain plug from front of tank and drain solution into an approved
location.
b. Place discharge wand into approved container.
Turn the needle valve to the wet setting and activate unit until all solution
has been flushed from the unit.
11. Press power button to turn off unit. Open the discharge ball valve or
trigger handle to relieve remaining pressure.
12. Before using unit with another chemistry, thoroughly flush with water.
Maintenance
WARNING
Performing any maintenance with the unit pressurized, may result in serious injury or death. Always ensure that the unit has been depressurized, before conducting any maintenance. Servicing or modifying unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
Maintaining Your Unit
To keep your unit operating properly, periodically perform the following maintenance procedures:
- Inspect the pump for wear and leaks.
- Inspect all hoses for leaks or excessive wear. Verify all hose clamps are in good condition and properly secured.
- Check the suction line and strainer for debris. Clean as needed.
- If foam quality beings to decrease, inspect the wadding. Replace as needed.
- Store battery in a half-charged state and maintain battery every 3-6 months.
Servicing Your Unit
To service your unit, refer to the service manual which includes:
• Troubleshooting procedures.
• Detailed parts breakdowns and illustrations.
• Part numbers of serviceable components and assemblies.
Scan this code for service manual
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>