FOAMit F10.0L 2.6 Gallon Pump Up Foam Unit User Manual
- May 15, 2024
- FOAMit
Table of Contents
FOAMit F10.0L 2.6 Gallon Pump Up Foam Unit
Specifications
- Model: F10.0L | F10.0L-PSG
- Capacity: 2.6 Gallons
- Product Overview: Pump-Up Foam Unit
Safety Precautions
Before operating the unit, it is crucial to read and understand all safety
precautions outlined in the user manual. Failure to follow these instructions
may result in serious injury or death.
Personal Protective Equipment (PPE)
Always wear the appropriate PPE as indicated in the Safety Data Sheet (SDS)
provided by the chemical manufacturer when handling or using the unit. This
includes protection for eyes, skin, and lungs against drifting spray.
FAQ
-
Q: Can I use hydrocarbons or flammable products with this unit?
A: No, using hydrocarbons or flammable products with the unit may result in explosions, fire, and serious injury or death. It is advised to avoid such products. -
Q: What should I do if the unit is damaged or leaking?
A: Do not use the unit if it is damaged or leaking, as it may lead to exposure to chemical solutions and serious injuries. Always ensure the unit is in proper working condition before operation.
2.6 Gallon Pump-Up Foam Unit
User Manual
F10.0L | F10.0L-PSG
READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN
A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
English (Original Instructions)
Safety
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in
personal injury or death from the improper use or the chemical solution.
Anyone handling, operating or using the unit must read and understand the
instructions in the manual. The buyer assumes all responsibility for safety
and proper use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective equipment
(PPE) may result in serious injury such as burns, rashes, eye, throat or lung
damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS)
when using or servicing the unit. Protect eyes, skin, and lungs against
drifting spray.
Chemical solutions may pose a health risk and death if they contact the
skin or eyes, are inhaled or swallowed. Always read and follow all chemical
safety precautions and handling instructions provided by the chemical
manufacturer and the SDS associated with the chemical solution before using
the unit.
Pressure within the equipment may cause an unexpected release of the chemical
solution and cause serious injury such as burns, rashes, eye damage, throat or
lung damage and death. Always depressurize and clean the unit after each use.
Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in
scalding, burns, serious injury or death. DO NOT use a solution with a
temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical
solutions, serious injury or death. Never use the unit if it is damaged or
leaking.
Never point the discharge wand at yourself, another person, or any object you
do not want covered
in chemical.
Use of hydrocarbons and flammable products may result in explosions, fire and
serious injury or death. Never use hydrocarbons or flammable products with the
unit.
Mixing an alkaline with an acid may result in a chemical reaction.
Overheating of the mixture may cause it to splatter caustic compounds or
release hazardous fumes, gas and vapors. Always flush the unit with fresh water
thoroughly when switching from an alkaline to an acid or an acid to an
alkaline.
NOTICE
Servicing, or modification, of this unit with parts not listed in this manual
may cause the unit to operate improperly. Do not use unauthorized parts when
servicing the unit.
Only lift and carry unit by the carrying handle. Do not lift or carry the unit
by the pump handle, hose, wand, or other components.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.
Product Overview
Requirements
Liquid temperature range | 40-100˚F (4.4-37.8˚C) |
---|---|
Chemical compatibility | Chemical products used with this equipment must be |
formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact our customer service department.
Specifications
| F10.0L| F10.0L-PSG
---|---|---
Power type| Manual
Chemical pickup type| Draws from pre-mixed solution
Number of products unit can draw from| One product
Suction line length/diameter| 18 in. (45.7 cm) clear poly tubing with 1/8 in.
(3.2 mm) inside diameter
Capacity| 2.6 gallons (10 liters)
Discharge line length/diameter| 6.5 ft. (2 m) hose, with 1/4 in. (6.4 mm)
inside diameter
*** Discharge wand/tip type| Polypropylene trigger handle with 17 in. (43.2
cm) wand extension and 110˚ fan tip| Polypropylene trigger handle with 65˚ fan
tip
Output distance| 1-3 ft. (0.3-0.9 m)| 3-5 ft. (0.9-1.5 m)
Output volume| 1 gal/min (3.8 l/min)| 2.5 gal/min (9.5 l/min)
Flow rate| 0.2 gal/min (0.8 l/min)| 0.5 gal/min (1.9 l/min)
Pump seals| Viton
*Rates given are based on chemical with viscosity of water. Rates can vary based on viscosity of product and fan tip size.
Product Components
Get to know the components that you will need to use, adjust or assemble.
Pump-Up Foam Unit • 2.6 Gallon
- Discharge wand
- Trigger gun
- Pressure relief valve
- Discharge hose
- Pump handle
- Tank head
- Solution tank
Using your unit
Operating Instructions
-
Remove components from packaging.
-
For F10.0L: Attach wand assembly to trigger handle. For F10.0L-PSG: Continue to step 3.
-
Pull the green pressure release valve until the red portion of the stem is showing to confirm the unit is not pressurized.
With the pump handle pressed fully down, hold the unit and unscrew the pump assembly from the tank head to access the filler hole.
Follow all instructions from the chemical manufacturer when filling the unit. Fill the tank ¾ full with pre-mixed solution. Do not overfill the tank. -
With the pump handle pressed fully down, hold the unit and screw the pump assembly back into the tank head to close the unit.
-
To pressurize the tank, rotate the handle of the pump assembly until it is free then pump up the unit. The pressure relief valve will begin leaking air when the tank is fully pressurized.
-
Once the desired pressure has been achieved, push the pump handle down and rotate to lock it in place.
-
begin foaming, point the discharge wand towards the area you wish to foam and squeeze the trigger handle. Release the handle to stop.
After Use Instructions -
Release air pressure from unit after each use by activating the pressure relief valve.
-
Empty out remaining solution and run fresh water through the unit to rinse all parts thoroughly after each use and before storage.
Using your unit
Maintenance Instructions
To keep your unit operating properly, periodically perform the following
maintenance procedures.
NOTE: Before servicing your unit, release air pressure from the unit by activating the pressure relief valve.
- Check the pump assembly for wear and leaks.
- Check the suction line for debris and clean as needed.
- Periodically lubricate the pump seal with food-safe lubricant. To lubricate the pump seal, raise the handle of the pump assembly and apply 5-10 drops of food safe lubricant between the pump and pump sleeve.
- If foam quality decreases, replace wadding with the following steps:
F10.0L:
-
Unthread the wand retaining nut (a) from the wand.
-
Remove old wadding (b), and insert new wadding.
-
Thread the wand retaining nut (a) back onto wand. F10.0L-PSG:
-
Unthread the wand (c) from the trigger gun.
-
Remove old wadding (d), and insert new wadding.
-
Thread the wand (c) back onto the trigger gun.
Attachment Instructions
F10.0L-PSG attachments: -
Remove wand (c) from the trigger gun, leaving the wadding (d) and o-ring (e) in the gun.
-
Install the attachment by threading it into the trigger gun. An additional o-ring will be supplied in the parts package of the attachment.
Drain tube attachment: -
Remove wand retaining nut (f) and o-ring (g) from the lance. Set aside to use with the drain tube.
-
Remove spray tip (h), leave wadding (i) in the lance.
-
Insert press fit adapter (j) into retaining nut (f),then place the o-ring (g) behind the press fit adapter (j).
-
Thread the lance into the wand retaining nut (f), securing the o-ring (g) and press fit adapter (j) place.
-
Press the drain tube (k) into the press fit adapter (j).
Servicing your unit
F10.0L:
10 liter pump-up foam unit
LC-SLA-F:
Short lance assembly – for 5L / 10L foam unit – includes spray tip, wadding,
gasket, and retaining nut
Item number | Description |
---|---|
1 | LC-SLA |
spray tip
2| LC-WD| Wadding disk for 5L / 10L (1 piece)
3| LC-WA-OR| O-ring for 5L / 10L wand assembly
4| LC-STB| Button spray tip for 5L / 10L
5| LC-WA-RN| Retaining nut for 5L / 10L wand assembly
Item number | Description |
---|---|
6 | LC-LLA |
nuts
7| LC-PRV| Pressure relief valve for 5L / 10L
8| LC-PSG| Poly spray gun for 5L / 10L – blue
9| LC-HA| Hose assembly for 5L / 10L
10| LC-PA| Manual pump assembly for 5L / 10L – Viton
11| LC-THA-F10.0L| Tank head assembly for 10L foam unit – with pressure
relief valve and 10L poly supply tube
12| TANK10L| 10 liter tank
13| LC-HNDL-CLP| Tank handle for 5L / 10L – with clips
Servicing your unit
F10.0L-PSG:
10 liter pump up foam unit with PSG12 trigger gun
PSGA14PU-MX:
Poly spray gun assembly for 1/4 in. hose – includes 4 in. black poly wand,
spray tip, mixing media, hose barb, and screw band clamp
Item number | Description |
---|---|
1 | PUWAND |
2 | WAAD-.625 |
3 | PSGORV |
4 | WAAD-.5 |
5 | PSG12 |
with red clip – 316SS internal spring – includes 2x o-ring
6| HBSS1214| Stainless hose barb ½ MPT x 1/4 barb
7| SSC14| Stainless screw band clamp for 1/4 in. hose
Item number | Description |
---|---|
8 | LC-PRV |
9 | LC-PA |
10 | LC-THA-F10.0L |
relief valve and 10L poly supply tube
11| TANK10L| 10 liter tank
12| LC-HNDL-CLP| Tank handle for 5L / 10L – with clips
Attachment options
Hoof Attachment
Item number | Description |
---|---|
1 | PWH |
2 | WAAD-.75 |
3 | PSGORV |
Drain Tube: LC-DT
Item number | Description |
---|---|
4 | LST14 |
15 in. long
5| PFA-DT| Press fit adapter for 1/4 in. tubing
Teat Dip Cup: DCWA-2DC
Item number | Description |
---|---|
6 | DC12 |
7 | PEL12F |
8 | PN126 |
9 | WAAD-1 |
10 | PSGORV |
Drain Plunger Assembly: DPA-PUF
Item number | Description |
---|---|
11 | PN1218 |
12 | TB38N-PE |
13 | SSC34 |
14 | WAAD-.75 |
15 | SSST |
16 | PLG-B5 |
Model: F10.0L | F10.0L-PSG
V20231130 • Page 9 of 9
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>