FOAMit SP10.0L-PSG 2.6 Gallon Pump Up Spray Unit User Manual
- March 19, 2024
- FOAMit
Table of Contents
- FOAMit SP10.0L-PSG 2.6 Gallon Pump Up Spray Unit User Manual
- Gallon Pump-Up Spray Unit User Manual
- SP10.0L | SP10.0L-PSG
- WARNING
- PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED
- NOTICE
- PROTECT THE ENVIRONMENT
- Product Overview
- Requirements
- Specifications
- Product Components
- Pump-Up Spray Unit • 2.6 Gallon
- Using your unit
- Operating Instructions
- After Use Instructions
- Maintenance Instructions
- LC-SLA-SP
- LC-SLA-SP:
- PSGA144-ST4003
- PSGA144-ST4003:
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FOAMit SP10.0L-PSG 2.6 Gallon Pump Up Spray Unit User Manual
Gallon Pump-Up Spray Unit User Manual
SP10.0L | SP10.0L-PSG
READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN
A
LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED
CORRECTLY!
Failure to read all the instructions before operating the unit may result in
personal injury or death from the improper use or the chemical solution.
Anyone handling, operating or using the unit must read and understand the
instructions in the manual. The buyer assumes all responsibility for safety
and proper use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective equipment
(PPE) may result in serious injury such as burns, rashes, eye, throat or lung
damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS)
when using or servicing the unit. Protect eyes, skin, and lungs against
drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin
or eyes, are inhaledor swallowed. Always read and follow all chemical safety
precautions and handling instructions provided by the chemical manufacturer
and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical
solution and cause serious injury such as burns, rashes, eye damage, throat or
lung damage and death.
Always depressurize and clean the unit after each use. Never leave the unit
unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in
scalding, burns, serious injury or death. DO NOT use a solution with a
temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical
solutions, serious injury or death. Never use the unit if it is damaged or
leaking.
Never point the discharge wand at yourself, another person, or any object you
do not want covered in chemical.
Use of hydrocarbons and flammable products may result in explosions, fire and
serious injury or death. Never use hydrocarbons or flammable products with the
unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating
of the mixture may cause it to splatter caustic compounds or release hazardous
fumes, gas and vapors. Always flush the unit with fresh water thoroughly when
switching from an alkaline to an acid or an acid to an alkaline.
NOTICE
Servicing, or modification, of this unit with parts not listed in this manual
may cause the unit to operate improperly. Do not use unauthorized parts when
servicing the unit.
Only lift and carry unit by the carrying handle. Do not lift or carry the unit
by the pump handle, hose, wand, or other components.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.
Product Overview
Requirements
Liquid temperature range | 40-100˚F (4.4-37.8˚C) |
---|
Chemical compatibility
| Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact our customer service department.
Specifications
SP10.0L | SP10.0L-PSG | |
---|---|---|
Power type | Manual | |
Chemical pickup type | Draws from pre-mixed solution | |
Number of products unit can draw from | One product | |
Suction line length/diameter | 18 in. (45.7 cm) clear poly tubing with 1/8 in. |
(3.2 mm) inside diameter
Capacity| 2.6 gallons (10 liters)
Discharge line length/diameter| 6.5 ft. (2 m) hose, with 1/4 in. (6.4 mm)
inside diameter
Discharge wand/tip type
| Polypropylene trigger handle with 17 in. (43.2 cm) wand extension and 80˚
fan tip| Polypropylene trigger handle with 40˚ fan tip
Output distance| 3-5 ft. (0.9-1.5 m)
Output volume| 0.2 gal/min (0.8 l/min)| 0.3 gal/min (1.1 l/min)
Flow rate*| 0.2 gal/min (0.8 l/min)| 0.3 gal/min (1.1 l/min)
Pump seals| Viton
*Rates given are based on chemical with viscosity of water and factory air pressure settings. These rates can vary based on viscosity of product and fan tip size.
Product Components
Get to know the components that you will need to use, adjust or assemble.
Pump-Up Spray Unit • 2.6 Gallon
- Discharge wand
- Trigger gun
- Pressure relief valve
- Discharge hose
- Pump handle
- Tank head
- Solution tank
Using your unit
Operating Instructions
- Remove components from
- For 0L: Attach wand assembly to the trigger handle. For SP10.0L-PSG: Continue to step 3.
- Pull the green pressure release valve until the red portion of the stem is showing to confirm the unit is not pressurized.
- With the pump handle pressed fully down, hold the unit and unscrew the pump assembly from the tank head to access the filler hole.
- Follow all instructions from the chemical manufacturer when filling the Fill the tank ¾ full with pre-mixed solution. Do not overfill the tank.
- With the pump handle pressed fully down, hold the unit and screw the pump assembly back into the tank head to close the unit.
- To pressurize the tank, rotate the handle of the pump assembly until it is free then pump up the The pressure relief valve will begin leaking air when the tank is fully pressurized.
- Once the desired pressure has been achieved, push the pump handle down and rotate to lock it in place.
- To begin spraying, point the discharge wand towards the area you wish to spray and squeeze the trigger handle. Release the handle to
After Use Instructions
- Release air pressure from unit after each use by activating the pressure relief valve.
- Empty out remaining solution and run fresh water through the unit to rinse all parts thoroughly after each use and before storage.
Maintenance Instructions
To keep your unit operating properly, periodically perform the following maintenance procedures:
- Check the pump assembly for wear and
- Check the suction line for debris and clean as
- Periodically lubricate the pump seal with food safe To lubricate the pump seal, raise the handle of the pump assembly and apply 5-10 drops of food safe lubricant between the pump and pump sleeve.
Servicing your unit SP10.0L
LC-SLA-SP
SP10.0L:10 liter pump-up spray unit
LC-SLA-SP:
Short lance assembly – for 10L spray unit – includes spray tip, gasket, and retaining nut
Item number | Description |
---|---|
1 | LC-SLA |
2 | LC-WA-OR |
3 | STB8002 |
– 0.2 GPM
4| LC-WA-RN| Retaining nut for 5L / 10L wand assembly
Item number| Description
---|---
5| LC-LLA| Long lance (10 in.) assembly for 5L / 10L – with retaining nuts
6| LC-PRV| Pressure relief valve for 5L / 10L
7| LC-PSG| Poly spray gun for 5L / 10L – blue
8| LC-HA| Hose assembly for 5L / 10L
9| LC-PA| Manual pump assembly for 5L / 10L – Viton
10
|
LC-THA-SP10.0L
| Tank head assembly for 10L spray unit – with pressure relief valve and tank
handle
11| TANK10L| 10 liter tank
12| LC-HNDL-CLP| Tank handle for 5L / 10L – with clips
Servicing your unit
PSGA144-ST4003
SP10.0L-PSG:10 liter pump-up spray unit with PSG trigger gun
PSGA144-ST4003:
Poly spray gun assembly for 1/4 in. hose – includes 4 in. black poly wand, spray tip, hose barb, and screw band clamp
Item number | Description |
---|---|
1 | ST4003SS |
2 | PW12M14F4 |
3 | PSGORV |
4
|
PSG12
| Poly spray gun with 2x 1/2 in. straight thread – gray handle with red clip –
316SS internal spring – includes 2x o-ring
5| HBSS1214| Stainless hose barb ½ MPT x 1/4 barb
6| SSC14| Stainless screw band clamp for 1/4 in. hose
Item number| Description
---|---
7| LC-PRV| Pressure relief valve for 5L / 10L
8| LC-PA| Manual pump assembly for 5L / 10L – Viton
9
|
LC-THA-SP10.0L
| Tank head assembly for 10L spray unit – with pressure relief valve and tank
handle
10| TANK10L| 10 liter tank
11| LC-HNDL-CLP| Tank handle for 5L / 10L – with clips
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>