BALLUFF BF-IDM30 RFID Reader User Guide
- June 27, 2024
- BALLUFF
Table of Contents
Operating Guide
Model:
BF-IDM30
RFID Reader
Company Addresses
Europe, Germany, Headquarter
Balluff GmbH
Schurwaldstraße 9
D-73765 Neuhausen, Germany
Argentina
Balluff Argentina S.R.L.
Echeverría 1050, 1st UF 2
1604 Buenos Aires – Florida Oeste
Australia
Balluff Pty Ltd.
18 Malvern Street
Bayswater, 3153 Victoria
Brasil
Balluff Controles Elétricos Ltda.
Rua Francisco Foga, 25 ,Distrito Industrial
CEP 13280.000 – Vinhedo – SP
Canada
Balluff Canada Inc.
2840 Argentia Road, Unit 2 Mississauga,
Ontario L5N 8G4
China
Balluff (Shanghai) Trading Co. Ltd.
No.800 Chengshan Rd, 8F, Building A, Yunding International Commercial Plaza
200125, Pudong, Shanghai
Japan
Balluff Co., Ltd.
Aqua Hakusan Bldg. 9F 1-13-7 Hakusan, Bunkyo-ku,
Tokyo 113-0001
Korea
Balluff Korea Ltd.
1210, Gwanggyo Business Center, 156, Gwanggyo-ro, Yeongtong-gu, Suwon-si
Gyeonggi-do, 16506
Mexico
Balluff de México S.A. de C.V.
Anillo Vial II Fray Junipero Serra No. 4416; Colonia La Vista Residencial
CP 76232 Delegación Epigmenio González, Querétaro
Taiwan
Balluff Taiwan Ltd.
Room G, 7F., No.573, Sec. 2, Taiwan Blvd., West Dist.,
Taichung City 40360
USA
Balluff Inc.
8125 Holton Drive, Florence
Kentucky 41042-0937
Purpose of the Device
The BF-IDM30 RFID Reader is intended to read and write ISO15693 / ISO14443
compliant data carriers via magnetic field communication.
Connecting the Device
BF-IDM30 devices operate in combination with BIS V processor units when connected to one of the ports labeled with “H1” to “H4”. For the connection a shielded standard type 4-wire cable M12 / A-coded is used.
To ensure reliable operation in strong EMC environments it is recommended to connect metal housings or dedicated functional ground pins directly to installations ground. The ground connection should be short and stable. Depending on the installation situation an indirect ground connection using a RC combination may be required.
For further notes concerning the installation of the processor unit please refer to the operating guide of the processor unit.
Installation notes
For proper operation at first a suitable mounting position has to be evaluated. The position should respect the recommended clear zones as described. Furthermore, please note that strong electrical or magnetic fields in the close environment may influence the RFID Reader.
Precise information concerning clear zones and distances are available on request.
Direct On-Wall mounting (Example):
Picture 3: Direct On-Wall mounting (Example)
Setup and Operation
For operation of BF-IDM30 Readers a BIS V type processor unit is needed. The processor unit is used as gateway between higher level controllers and RFID Reader. Any communication from and to data carriers respectively RFID Readers is managed by the processor unit. Further information concerning the operation or parameterization of RFID Readers can be found operating guide of the processor unit.
Status Indicators
The device will show its status using the 2 LEDs at the corners of the housing. In normal operation state the meaning of these lights are as follows:
- Green light “Power” indicates that the device is connected to the processor unit and ready to operate.
- Orange light “Tag present” indicates that a RFID tag has been detected in front of the transceiver coil.
Electrical Data
Operating voltage (nominal) ——– +24 V DC
Current draw (at +24 V DC)——– ≤ 200 mA
Operating Frequency——– 13.56 MHz
Active principle——– Magnetic field
Transmit power——–Class 5
Mechanical Data
Housing Material Metal ——– / ABS-GF16 / PBT / PA12-GF30
Weight max. ——– 400g
Ambient temperature ——– 0…+70°C
Statements
This product was developed and manufactured under observance of the guidelines applicable in the USA and Canada.
FCC :
This device complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This device complies with the safety requirements
for RF exposure for mobile (>20 cm) use conditions in accordance with FCC rule
part 2.1091
FCC ID: 2AGZY-BFIDM30
This device complies with Section 15 of the FCC Rules. The following two conditions apply to operation:
- this device may not cause interference
- this device must accept any interference, including interference that may cause undesired operation of the device
Changes or modifications not expressly approved by the party responsible for compliance voids the user’s authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ISED Canada:
This equipment complies with ISED Canada RSS-102 radiation exposure limits set forth for the general population. This equipment complies with the safety requirements for RF exposure in accordance with RSS-102 Issue 5 section 2.5.2 for mobile (>20 cm) use conditions.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
- this device may not cause interference
- this device must accept any interference, including interference that may cause undesired operation of the device
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>