BALLUFF BF-IDU07 Ultra High Frequency Passive Radio Frequency Identification Processor Installation Guide
- June 6, 2024
- BALLUFF
Table of Contents
- GENERAL VIEW
- INSTALLATION GUIDE
- TECHNICAL DATA
- CONNECTIVITY
- DIGITAL I/O (-12 MODELS)
- DIMENSIONS
- INSTALLATION GUIDELINES
- INSTALLATION
- COMPL IANCE
- GENERAL VIEW
- INSTALLATION GUIDE
- TECHNICAL DATA
- CONNECTIVITY
- DIGITAL I/O (-12 MODELS)
- DIMENSIONS
- INSTALLATION GUIDELINES
- INSTALLATION
- COMPL IANCE
- Power Supply
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BF-IDU07
BIS U-620-068-1X1-00-SX
Ultra High Frequency Passive Radio Frequency,
Identification Processor
GENERAL VIEW
LED INDICATORS
| READY| The READY LED is ON after the power
up sequence has been completed.
---|---|---
| RF| The RF LED illuminates when RF power is being transmitted by the
antenna.
| COM| The COM (communications) LED flashes ON and OFF when data is being
transmitted between the antenna and a tag.
When in Continuous Read mode, the COM LED will remain ON and will turn
OFF briefly only while data is being read from or written to a tag.
INSTALLATION GUIDE
This document provides instructions and information designed to assist users in the hardware setup of the BIS U620-068-1×1-00-Sx Processor. For configuration details see the BIS U-62_ Processor Manual.
PACKAGE CONTENTS
Qty| Description
1| BIS U-620-068-1×1-00-Sx Processor
1| UHF Series Configuration Tag
1| This Installation Guide
TECHNICAL DATA
ELECTRICAL FEATURES
Power Supply| 19.2…28.8 V DC
DC Input Current| 1 A
Communication Interface Baud Rate| RS232 9600 (default ) … 115200
RADIO FEATURES| EU| US
Frequency (MHz) ETSI EN 302 208 FCC part 15.247| 865…868| -902…928
Number of Channels| 4 fixed| 50 hopping
Frequency Tolerance| ± 10 ppm over entire temp
range
Air Interface| EPC C1G2
Conducted Output Power| 500 mW (27 dBm) max
Antenna Connector| Reverse TNC
ENVIRONMENTAL FEATURES
Operating Temperature| -20…+50 °C
(-4…+122 °F)
Storage Temperature| -20…+70 °C (-4…+158 °F)
Humidity max.| 90 % noncondensing
Vibration Resistance EN 60068-2-6| 14 mm @ 2…10 Hz;
1.5 mm @ 13…55 Hz;
2 g @ 70..200 Hz;
2 hours on each axis
Shock Resistance EN 60068-2-27| 30 g; 11 ms; 3 shocks on each axis
Protection Class EN 60529| IP65*
PHYSICAL FEATURES
Dimensions| 164 x 112 x 48 mm (6.46 x 4.41 x 1.88 in)
Weight| 560 g (19.8 oz)
Enclosure| Powder Coated Aluminum
USER INTERFACE
LED Indicators| READY, RF, COM
- When all connectors and antenna are correctly installed.
The BIS U-620-068-1×1-00-Sx Processor and its antenna are intended for indoor use only.
CONNECTIVITY
M12 8 pin Male Connector (Data and Power Supply)
See the BIS U-62_ Processor Manual for a complete list of accessories including alternative cables and connectors.
DIGITAL I/O (-12 MODELS)
This connector is available on models BIS U-620-068-1×1-00-S29. See the BIS U-62_ Processor Manual for details
DIMENSIONS
INSTALLATION GUIDELINES
- RF performance and read/write range can be negatively impacted by the proximity of metallic objects and liquids. Avoid mounting the BIS U-3x… antenna within 15 cm (6 inches) of any metallic object or wet surface.
- Do not route cables near other unshielded cables or near wiring carrying high voltage or high current. Cross cables at perpendicular intersections and avoid routing cables near motors and solenoids.
- Avoid mounting the Processor near sources of EMI (electromagnetic interference) or near devices that generate high ESD (electro-static discharge) levels. Always use adequate ESD prevention measures to dissipate potentially high voltages.
- If electrical interference is encountered (as indicated by a significant reduction in reading/write performance), relocate the Processor to an area free from potential sources of interference.
INSTALLATION
The BIS U-620-068-1×1-00-Sx RFID Processor is designed for point-to-point RFID applications, where the distance from host to Processor is less than 15 meters (50 feet). The Processor connects directly to a serial communications port on a host computer via an RS232-compatible serial interface cable.
- Select a suitable location for the BIS U-62… Processor and BIS U-30… Antenna.
- Mount the BIS U-30… Antenna (within the cable distance of the Processor) and attach the BIS U-30… Antenna cable as described in the installation guide included with the antenna.
- Fasten the Processor to your mounting fixture using two M5 (#10) diameter screws (not included) and secure them with appropriate washers and nuts. Tighten screws to 1.7 Nm or 15 lbs per inch ± 10%. Connect the antenna cable to the UHF Processor.
- Connect the BCC0ETJM12 8-pin female connector to the M12 8-pin male interface connector on the BIS U620-068-1×1-00-Sx Processor. Connect the BCC0ETJ9-pin female D-sub connector to an RS232 COM port on the host computer. Tighten the cable’s two locking thumbscrews.
- Connect the power supply to the VDC (red) and GND (black) wires on the BCC0ETJcable.
- Apply power to the Processor after all cable connections have been made. The LEDs on the unit will flash. The READY LED is ON after the power-up sequence has been completed.
- On the host computer, set the COM port parameters to 9600 baud, 8 data bits, 1 stop bit, no parity, and no handshaking.
To verify operations, download the Balluff Dashboard™ Configuration Tool from www.balluff.com. The Balluff Dashboard™ Configuration Tool allows users to configure and control their BIS U-620-068-1×1-00-Sx Processors and send RFID commands for testing purposes.
COMPL IANCE
Only BIS U-30… family antennas are certified for use with the BIS U-620-068-1×1-00-Sx Processors. This product is intended to be installed by qualified personnel only. This product must not be used in explosive environments.
Power Supply
This device is intended to be supplied by a UL Listed or CSA Certified Power
Unit with a «Class 2» or LPS power source.
BIS U-620-068-101-00-Sx:
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance void the user’s authority to operate this equipment.
This device complies with part 15 of the FCC Rules and Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiofrequency radiation exposure Information: This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
BF-IDU07
BIS U-626-069-1X1-06-S3X
Ultra High-Frequency Passive Radio Frequency,
Identification Processor
GENERAL VIEW
LED INDICATORS
| READY| The READY LED is ON after the power
up sequence has been completed.
---|---|---
| RF| The RF LED illuminates when RF power is being transmitted by the
antenna.
| COM| The COM (communications) LED flashes ON and OFF when data is being
transmitted between the antenna and a tag.
When in Continuous Read mode, the COM LED will remain ON and will turn
OFF briefly only while data is being read from or written to a tag.
| COM| Default IP Address enabled
(192.168.253.110)
---|---|---
| CUSTOM| User assigned IP Address enabled
INSTALLATION GUIDE
This document provides instructions and information designed to assist users in the hardware setup of the BIS U620-068-1×1-00-Sx Processor. For configuration details see the BIS U-62_ Processor Manual.
PACKAGE CONTENTS
Qty| Description
1| BIS U-620-068-1×1-00-Sx Processor
1| UHF Series Configuration Tag
1| This Installation Guide
TECHNICAL DATA
ELECTRICAL FEATURES
Power Supply| 19.2…28.8 V DC
DC Input Current| 1 A
Communication Interface Baud Rate| RS232 9600 (default ) … 115200
RADIO FEATURES| EU| US
Frequency (MHz) ETSI EN 302 208 FCC part 15.247| 865…868| -902…928
Number of Channels| 4 fixed| 50 hopping
Frequency Tolerance| ± 10 ppm over entire temp
range
Air Interface| EPC C1G2
Conducted Output Power| 500 mW (27 dBm) max
Antenna Connector| Reverse TNC
ENVIRONMENTAL FEATURES
Operating Temperature| -20…+50 °C
(-4…+122 °F)
Storage Temperature| -20…+70 °C (-4…+158 °F)
Humidity max.| 90 % noncondensing
Vibration Resistance EN 60068-2-6| 14 mm @ 2…10 Hz;
1.5 mm @ 13…55 Hz;
2 g @ 70..200 Hz;
2 hours on each axis
Shock Resistance EN 60068-2-27| 30 g; 11 ms; 3 shocks on each axis
Protection Class EN 60529| IP65*
PHYSICAL FEATURES
Dimensions| 164 x 112 x 48 mm (6.46 x 4.41 x 1.88 in)
Weight| 560 g (19.8 oz)
Enclosure| Powder Coated Aluminum
USER INTERFACE
LED Indicators| READY, RF, COM
- When all connectors and antenna are correctly installed.
The BIS U-626-069-1×1-06-S3x Processor and its antenna is intended for indoor use only
CONNECTIVITY
M12 4-pin D-Coded Female Connector (for Ethernet)
M12 5-pin Male Connector (for Power Supply)
See the BIS U-62_ Processor Manual for a complete list of accessories including alternative cables and connectors.
DIGITAL I/O (-12 MODELS)
This connector is available on models BIS U-620-067-1×1-04-S32. See the BIS U-62_ Processor Manual for details.
DIMENSIONS
INSTALLATION GUIDELINES
- RF performance and read/write range can be negatively impacted by the proximity of metallic objects and liquids. Avoid mounting the BIS U-3x… antenna within 15 cm (6 inches) of any metallic object or wet surface.
- Do not route cables near other unshielded cables or near wiring carrying high voltage or high current. Cross cables at perpendicular intersections and avoid routing cables near motors and solenoids.
- Avoid mounting the Processor near sources of EMI (electromagnetic interference) or near devices that generate high ESD (electro-static discharge) levels. Always use adequate ESD prevention measures to dissipate potentially high voltages.
- If electrical interference is encountered (as indicated by a significant reduction in reading/write performance), relocate the Processor to an area free from potential sources of interference.
INSTALLATION
The BIS U-626-069-1×1-06-S3x Processor is designed for Industrial Ethernet RFID applications, where the Processor is connected in an Industrial Ethernet or TCP/IP network via compatible cables through a hub or directly to an Industrial Ethernet host.
- Select a suitable location for the BIS U-62… Processor and BIS U-30… Antenna.
- Mount the BIS U-30… Antenna (within the cable distance of the Processor) and attach the BIS U-30… Antenna cable as described in the installation guide included with the antenna.
- Fasten the Processor to your mounting fixture using two M5 (#10) diameter screws (not included) and secure them with appropriate washers and nuts. Tighten screws to 1.7 Nm or 15 lbs per inch ± 10%. Connect the antenna cable to the UHF Processor.
- Connect the BCC0CT1 M12 4-pin male connector to the M12 4-pin female interface connector on the BIS U626-069-1×1-06-S3x Processor. Connect the BCC0CT1 RJ45 male connector to the LAN hub/switch. If connecting directly to the host computer you will need to use an additional crossover cable.
- Build a power supply cable using the BCC06ZF M12 5pin female connector. Use minimum 24 AWG wires for connection to the power supply lines according to the Vdc connector pinout. Connect the BCC06ZF M12 5pin female connector to the M12 5-pin male connector on the Processor. Connect the other end of the cable (wires or user-supplied connectors) to the power supply.
- Apply power to the Processor after all cable connections have been made. The LEDs on the unit will flash. The READY LED is ON after the power-up sequence has been completed. Then one of the Industrial Ethernet Address LEDs will remain on either Default or Custom.
To verify operations, download the Balluff Dashboard™ Configuration Tool from
www.balluff.com. The Balluff Dashboard™
Configuration Tool allows users to configure and control their BIS
U-626-069-1×1-06-S3x Processor s and send RFID commands for testing purposes.
For connection, details see the BIS U-62_ Processor Manual and the Balluff
Dashboard™ Configuration Tool Manual.
COMPL IANCE
Only BIS U-30… family antennas are certified for use with the BIS U-626-069-1×1-06-S3x Processors. This product is intended to be installed by Qualified Personnel only. This product must not be used in explosive environments. Only connect Ethernet and data port connections to a network that has routing only within the plant or building and no routing outside the plant or building.
Power Supply
This device is intended to be supplied by a UL Listed or CSA Certified Power Unit with a «Class 2» or LPS power source.
BIS U-626-069-101-06-S3x:
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance void the user’s authority to operate this equipment.
This device complies with part 15 of the FCC Rules and Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiofrequency radiation exposure Information: This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.