Carrier i-Vu Pro v9.0 Life Sciences CIV-OPNPRLS User Guide
- June 25, 2024
- Carrier
Table of Contents
i-Vu® Pro v9.0
Life Sciences Best Practices Guide
i-Vu Pro v9.0 Life Sciences CIV-OPNPRLS
Verify that you have the most current version of this document from www.hvacpartners.com, the Carrier Partner Community website, or your local Carrier office. Important changes are listed in Document revision history at the end of this document.
Carrier© 2024. All rights reserved.
The content of this guide is furnished for informational use only and is
subject to change without notice. Carrier assumes no responsibility or
liability for any errors or inaccuracies that may appear in the informational
content contained in this guide.
What is i-Vu® Pro for Life Sciences?
i-Vu® Pro for Life Sciences is a product bundle that includes licensed
features and add-ons necessary to apply the product on a 21 CFR Part 11
compliant, or other validated site.
The i-Vu® Pro for Life Sciences license includes everything that the i-Vu® Pro
Unlimited license includes, Advanced Security, Advanced Alarming, and Advanced
Reporting, plus the LDAP/AD and Trend Export add-ons. Licensed features
specific to Life Sciences include:
- Electronic records
- Electronic signatures
- Pre-configured critical variance tracking reports
- Mean Kinetic Temperature (MKT)
- Trend Values
- Value Out of Range
See the i-Vu® Pro v9.0 User Manual for a complete description of i-Vu® Pro for
Life Sciences capabilities.
i-Vu® Pro for Life Sciences v9.0 features and functionality were found to meet
applicable FDA 21 CFR Part 11 requirements, according to a third-party
assessment by Protocol Link. The assessment report is available upon request.
All clients are encouraged to conduct an on-site audit of our Software
Development Life Cycle (SDLC), as well as Development and Validation
practices.
Requirements
To use the i-Vu® Pro v9.0 for Life Sciences features you must:
- Be running i-Vu® Pro v9.0 with a i-Vu® Pro for Life Sciences license
- Have the latest cumulative patch installed
Life Sciences best practices
Upgrading from a previous version of i-Vu® Pro
To convert a customer’s license from a previous version of i-Vu® Pro (CIV-
OPNPR) or i-Vu® Pro Unlimited (CIV-OPNPRUL) to i-Vu® Pro for Life Sciences
v9.0 (CIV-OPNPRLS), contact your Carrier Regional Sales Manager. For general
upgrade instructions see the i-Vu® Pro v9.0 Upgrade Guide. Follow the steps
below to ensure your system’s previously validated drivers and programs are
successfully transferred to the new, upgraded system.
Before performing the upgrade
- For controllers with sufficient memory, download source to the controller for ability to recreate the original programming by uploading from the controller.
- Control program names should contain the version number of your program to allow recognition of program differences.
- Run an equipment report
- If upgrading from v7.0 or later, use custom report Programs and Drivers to list control program names and driver versions. To download the template for this report, see the Carrier Partner Community web page.
- If upgrading from a version earlier than v7.0, use the Equipment Checkout report to list program names. There is no report for driver versions.
After performing the upgrade:
Run the equipment report again to compare against the report you ran before
the upgrade.
Network and server security
Review the Security Best Practices for an i-Vu® Pro v9.0 system document
and utilize the Security Checklist to configure the system securely and in
compliance with site requirements.
System access policies
In addition to the user recommendations in the Security Best Practices for an
i-Vu® Pro v9.0 system document, implement site system access policies in
accordance with the site’s requirements.
-
On the System Settings > Security tab, configure or confirm the following:
- Establish password policies, including complexity, reuse, and expiration requirements
- Lock out operators after a specified number of failed attempts
- Log out operators after a specified period of inactivity
-
The LDAP/AD add-on is included with the i-Vu® Pro for Life Sciences license. This add-on can be used to authenticate operators using their i-Vu® Pro login names and LDAP/AD passwords. This enables the site’s IT staff to manage password policy according to site IT policies.
-
On the System Options > Operators tab, it is recommended that:
- Force user to change password at login is selected to facilitate password secrecy for new operators
- Do not use automatic logoff for this operator and Exempt From Password Policy are not selected for any operator
- Run the Security > Operator Information report to determine if any existing users are exempt from Automatic Logoff or the system’s Password Policy, and whether an operator can e-sign reports.
-
Adding, editing, and deleting system operators is recorded electronically in the audit log.
-
Periodically check for inactive or unused accounts and remove them.
1. Go to the System Options > Operators tab.
2. Run the Security > Operator Information report. NOTE A security report using the sreview manual command is also available. Review the following items.- Operators never logged in: Operators last login > 180 days: Optionally, site specific procedures and third-party tools can be used, if required, to further control and monitor i-Vu® Pro access, for example:
- Restrict access to a defined range of IP addresses.
- Enable intrusion protection at the hardware level of the website server.
- Record intrusion events in the server’s monitored event logs.
Role-based access privileges
- On the System Options > Privilege Sets tab, establish role-specific privilege profiles to be assigned to individual operators.
- On the System Settings > Security tab, it is recommended that:
- Location-dependent security is selected to limit operator privileges to the areas of the system that they are authorized for.
- Strict operator log off, lock out, and password rules are configured.
- Ensure only authorized individuals are given the privilege to sign reports. Electronic signatures uploaded for use within the system are intended to be the legally binding equivalent of traditional handwritten signatures. The Operator Information report shows which operators can e-sign reports, which privilege sets they have, and their starting location.
- Ensure only authorized individuals are given the “Engineer System” privilege, which allows them to configure semantics tags for the Out of Range report.
- Disable the “Delete Non-Critical Alarms” and “Delete Critical Alarms” privileges for all operators to ensure that all alarms are represented on reports.
Establish policy for retaining audit trail information
- On the System Settings > Security tab, configure the system to Log Audit Data to Database. Configure the audit log retention period to comply with site retention policies.
- For each critical equipment for which change reasons should be captured in the audit log, on the User Tree, right-click the equipment, and select Configure from the drop-down list. Then, select the Require operator to record any changes to control program and when acknowledging alarms checkbox.
NOTE In order to record change reasons for alarm acknowledgment, for each required alarm you must also enable Alarm requires acknowledgment or Return requires acknowledgment (or both).
Backup and restore
Ensure that your site has established adequate backup and restore procedures.
See “To back up a system” in the i-Vu® Pro v9.0Installation Guide. If
required, third-party software such as Neverfail can be utilized to configure
a system for high availability.
Validate security settings
Run a security report using the sreview manual command. Use the resulting
report to compare your configured settings to the recommended settings found
in the i-Vu® Pro Security Best Practices v9.0 document.
Verify Out of Range report parameters
Out of Range report parameters must be configured as semantic tags. See “To
Configure Out of Range reports with Semantics” in the i-Vu® Pro v9.0 Help for
details on report parameters. To verify that the expected parameter values
have been used for your scheduled Out of Range report, you can schedule one of
the “Out of Range Tags” custom reports to run concurrently with your Out of
Range report. To download the templates for these reports, see the ” Support >
Download > Training Materials > Custom Reports” section of the i-Vu® Systems
web page.
Daylight Saving Time transitions
During certain Daylight Saving Time events, controller trend data may be
preserved by quarantine at the server. A Quarantine Summary report indicates
where quarantined data may exist in a system. The Trend Value report has an
option to report on quarantined data.
Document revision history
Important changes to this document are listed below. Minor changes such as typographical or formatting errors are not listed.
Date | Topic | Change description | **Code*** |
---|---|---|---|
No updates yet |
- For internal use only
i-Vu® Pro v9.0
Life Sciences Best Practices Guide
Carrier Proprietary and Confidential
©2024 Carrier.
All rights reserved.
Carrier ©2024 · Catalog No. 11-808-1101-01 · 5/15/2024
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>