Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.
RangeXtender 40
Laser receiver for all line lasers with RX-READY technology.
General safety instructions
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- The structure of the device must not be modified in any way.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
Safety instructions
- Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
-
A Sound ON / OFF
-
B Receiver field for laser beam
-
C Universal mount
-
D Battery compartment
-
E LED’s for laser indication (front, backside)
-
F ON / OFF switch
-
G LED acoustic signal
-
H Central area switchover
-
I LED central area:
green = small
red = large -
J Head/side magnets
Inserting the battery
Open the battery compartment and insert batteries according to the symbols. Be
sure to pay attention to polarity.
Working with the laser receiver RX
Use the laser receiver RX for levelling over longer distances or when the laser lines are no longer visible. Switch on with button F. The LED central area lights up and a signal sounds.
Line lasers: This button switches hand receiver mode on and off.
RX 40: The sensitivity of the central area can be adjusted using the
button.
Set the line laser to hand receiver mode. The laser lines will now pulsate
with high frequency, making the laser lines darker. The laser receiver can
detect these pulsating laser lines up to a maximum distance of 40 m.
Now move the receiver field (B) of the laser receiver through the laser lines
upwards and downwards (horizontal laser line) and/or sideways (vertical laser
line) until the centre LED lights up. Now mark the horizontal and/or vertical
reference dimension.
Minimum distance from the laser device about 3 m. Pay attention that the laser lines are not reflected by reflective surfaces. Such reflections can lead to false indications.
The light intensity of the laser lines is greatest at the centre and diminishes toward the ends. This can reduce the maximum reception range of the laser receiver.
Used with levelling staff
The laser receiver RX can be fitted on measuring staffs with the universal mount. The Flexi measuring staff (Art. No. 080.50) is always recommended when measuring from floor heights. It also allows you to determine heights directly without any need for calculation.
Danger – powerful magnetic fields
Powerful magnetic fields can adversely affect persons with active medical
implants (e.g. pacemaker) as well as electromechanical devices (e.g. magnetic
cards, mechanical clocks, precision mechanics, hard disks).
With regard to the effect of powerful magnetic fields on persons, the
applicable national stipulations and regulations must be complied with such as
BGV B11 §14 „electromagnetic fields“ (occupational health and safety –
electromagnetic fields) in the Federal Republic of Germany.
To avoid interference/disruption, always keep the implant or device a safe
distance of at least 30 cm away from the magnet.
Technische Daten (Technische Änderungen vorbehalten. 18W11)
Laser-Empfangsbereich| max. 40 m
Stromversorgung| 2 x AAA 1,5 Volt Batterien
Arbeitsbedingungen
| 0°C…40°C, Luftfeuchtigkeit max. 80%rH, nicht kondensierend, Arbeitshöhe max.
4000 m über NN (Normalnull)
Lagerbedingungen| -10°C…70°C, Luftfeuchtigkeit max. 80%rH
Abmessungen (B x H x T)| 60 x 110 x 23 mm
Gewicht (inkl. Batterie)| 150 g
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=raxten40
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>