dormakaba 10-F10 Exit Ddevice Operators Installation Guide
- June 25, 2024
- dormakaba
Table of Contents
- dormakaba 10-F10 Exit Ddevice Operators
- Product Usage Instructions
- Saffire LX & Saffire EVO LZ Match-up Chart
- FCC Compliance Statement
- 1 Introduction and Disclaimers
- Definitions of Acronyms
- Recommended Tools (not included)
- Components
- Installation Steps
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
dormakaba 10-F10 Exit Ddevice Operators
Specifications :
- Models: Saffire LX and Saffire EVO LZ
- Manufacturer: Dormakaba
Product Usage Instructions
-
Introduction and Disclaimers:
Before proceeding with the installation, read all instructions carefully and ensure you have the necessary tools and components. -
Definitions of Acronyms:
Refer to the provided list of acronyms for better understanding of the components and installation process. -
Recommended Tools:
Ensure you have the recommended tools for installation, including a drill, screwdriver, and measuring tape. -
Components:
Refer to the provided list of components to verify you have all the required parts for installation.
Installation Steps:
-
Install Key Cylinder:
Begin by installing the key cylinder according to the provided instructions. -
Install Mounting Option:
Choose the appropriate mounting option and install it securely as per the manufacturer’s guidelines. -
Install the Lock Spindle:
Insert and secure the lock spindle in place following the specified orientation. -
Install the Lock Housing on the Door:
Mount the lock housing onto the door using the correct screws and alignment. -
Install Exit Device:
Attach the exit device to the door as instructed, ensuring proper alignment and functionality. -
Connect Cables & Install Enclosure:
If applicable, connect any cables and install the enclosure securely around the device. -
Connect Cables & Install Enclosure (SVR ONLY):
Follow specific instructions for SVR models regarding cable connection and enclosure installation. -
Install Outside Lever Handle:
Add the outside lever handle to complete the installation, ensuring it operates smoothly. -
Test Lock Functionality:
Test the lock to ensure it functions correctly before proceeding to program it. -
Program the Lock:
Follow the provided steps to program the lock according to your preferences and security needs.
FAQ :
-
Q: Can I install this product on any type of door?
A: The product is designed for specific door types mentioned in the manual. Ensure compatibility before installation. -
Q: Do I need any special skills to install this product?
A: Basic knowledge of door hardware installation is recommended for a successful installation process.
Saffire LX Saffire EVO
Exit device operators
Installation Instructions
Saffire LX & Saffire EVO LZ Match-up Chart
PK3713 – Table 1
ADAPTER PLATE PART NUMBER| SECONDARY BACKPLATE| DRIL. TEMPLATE NUMBER| SVR
DRILLING TEMPLATE NO.| MANUFACTURER OF EXITE DEVICE| EXIT DEVICE MODEL NUMBER
| | DT-516418-1| DT-516418-15| DETEX| SURFACE| 20/F20
041-515933-1XXX|
- DT-516418-2
- DT-516418-1
|
- DT-516418-15
- DT-516418-15
|
- DORMA
- VON DUPRIN
|
- SURFACE
- SURFACE
|
- 9400/F9400
- 9827/9927 EO-F
| DT-516418-1| DT-516418-15| PRECISION| SURFACE| 22/FL22
| | DT-516418-1| | DETEX| RIM| 10/F10
041-515933-1HXXX| DT-516418-1
DT-516418-2
|
- DORMA
- VON DUPRIN
| RIM
RIM
|
- 9300/F9300
- 98/99 EO-F
| DT-516418-1| PRECISION| RIM| 21/FL21
041-515933-2HXXX| 041-515972| DT-516418-3| | VON DUPRIN| MORTISE| 9875/9975
EO-F
041-515933-4XXX| | DT-516418-4| DT-516418-15| ARROW| SURFACE| S3788
041-515933-4HXXX| DT-516418-4| | ARROW| RIM| S3888
| | DT-516418-5| DT-516418-15| YALE| SURFACE| 7170
041-515933-5XXX| DT-516418-5| DT-516418-15| CORBIN RUSSWIN| SURFACE| ED5400
| DT-516418-6| DT-516418-15| HAGAR| SURFACE| 4500
| | DT-516418-5| | CORBIN RUSSWIN| RIM| ED5200
041-515933-5HXXX| DT-516418-6| HAGAR| RIM| 4500
| DT-516418-5| YALE| RIM| 7100-36
041-515933-6XXX| 041-515972| DT-516418-7| DT-516418-15| ARROW (OLD CHASSIS)|
SURFACE| S1708/S3708
041-515933-6HXXX| 041-515972| DT-516418-7| | ARROW (OLD CHASSIS)| RIM|
S1808/S3808
041-515972| DT-516418-7| ARROW (NEW CHASSIS)| MORTISE| S1908/S3908
041-515933-7HXXX| 041-515972| DT-516418-8| | YALE| CONCEALED| 7160
041-515933-8HXXX| 041-515972| DT-516418-9| | DORMA| CONCEALED| 9100/F9100
041-515972| DT-516418-10| VON DUPRIN| CONCEALED| 9847/9947 EO-F
041-515933-9HXXX| | DT-516418-11| | DETEX| RIM| V40
041-515933-10XXX| | DT-516418-12| DT-516418-15| SARGENT| SURFACE| 8710 & 8713
041-515933-11HXXX| | DT-516418-13| | MONARCH| RIM| 18-R
041-515933-12HXXX| 041-515972| DT-516418-14| | DORMA| MORTISE| 9500/F9500
041-515933-13RXXX| | DT-516418-16| DT-516418-15| DORMA| SURFACE| 8400
041-515933-13LXXX| | DT-516418-15| DORMA
041-515933-13HRXXX| | | DORMA| RIM| 8300
041-515933-13HLXXX| | | DORMA
041-515933-14| | | DT-516418-15| PHI/RELIANT| SURFACE| 5100/FL5100
DT-516418-17| DT-516418-15| VON DUPRIN| SURFACE| 22
041-515933-14H| | | PHI/RELIANT| RIM| 5200/FL5200
| VON DUPRIN| RIM| 22
Models: Saffire LX and Saffire EVO LZ
Caution: Changes or modifications to this equipment not expressly
approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
- If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
RF Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter. To avoid the possibility
of exceeding the FCC radio frequency exposure limits, this equipment should be
installed and operated with minimum distance 20 cm between the antenna and
your body during normal operation. Users must follow the specific operating
instructions for satisfying RF exposure compliance.
ISED non-interference disclaimer:
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device. This
equipment complies with ISED RSS-102 radiation exposure limits set forth far
an uncontrolled environment. This transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter.
1 Introduction and Disclaimers
- Caution : Please read and follow all directions carefully. Wear safety glasses when making the holes.
- Target Audience : These instructions are designed for use by maintenance professionals or lock installers who are familiar with common safety practices and competent to perform the steps described. dormakaba is not responsible for damage or malfunction due to incorrect installation however arising.
- Important: Carefully inspect windows, doorframe, door, etc. to ensure that the recommended procedures will not cause damage. dormakaba standard warranty does not cover damages caused by installation. Respect applicable building codes regarding handle height.
- Technical Assistance For technical assistance, call: 1.877.468.3555 / +1.514.735 5410 1.800.999.6213 / +1.248.837.3700
Definitions of Acronyms
- CNR: charges sur les normes radioelectriques
- FCC: Federal Communication Commission
- ISED: Innovation, Science and Economic Development Canada
- RF: Radio frequency
- RFID: Radio Frequency Identification
- RSS: Radio Standards Specifications
- МКО: mechanical key override
- SVR: Surface Vertical Rod
- EO: Electronic Override
Recommended Tools (not included)
- Drill bits: 1/4″ / 5/16″ / 1/2″ / 3/4″ /1-1/8″
- Phillips screwdriver #2)
- Small flat screwdriver
- Hexagonal key 3mm / 1/8″‘ (Allen Key)
Components
- Standard mounting
- Secondary back plate mounting
Components
Possible hardware included with lock
ITEM NO.| PART NUMBER| DESCRIPTION| QTY.
1| 017‐515483| OUTSIDE BUSHING| 1
2| 999‐511404| BINDING BARREL 10‐24| 4
3| 020‐515480‐9/10|
- SPINDLE LATCH EXIT DEVICE
- ARROW S1808/S3808; S1708/S3708; S1908/S3908; S3788
|
1
4| 020‐516459‐1/2/3/4/5/6/7/8/9| SPINDLE LATCH EXIT DEVICE STANDARD| 1
5| 020‐516465| SPINDLE LATCH MORTISE DORMA/VON DUPRIN| 1
6| 941‐514793| SET SCREW M6 x 8MM| 1
7| 810‐512494‐B| SCREW 12‐24 x 1 ‐ 3/8 FLAT HEAD, HEX| 3
8| 810‐508429‐6/10| SCREW 10‐24 x 1‐1/2 OR 1‐3/4 FLAT HEAD, HEX| 4
9| 810‐511097‐1| SCREW 10‐24 x 3/8 FLAT HEAD PHILLIPS NO.2| 3
10| 890‐514713| SCREW NO.6 x 5/8 PAN HEAD PHILLIPS| 2
11| 810‐511411| SCREW 12‐24 x ½ FLAT HEAD PHILLIPS NO.2| 1
12| 118‐515979| KEY & CYLINDER SAFFIRE LX| 1
13| 810‐516437| SCREW 10‐32 x 7/16 ROUND HEAD PHILLIPS NO.2| 1
14| 041‐515465| KEY CYLINDER ACCESS PLATE| 1
15| 810‐509093| SCREW 6‐32 x 5/16 FLAT HEAD PHILLIPS NO.2| 2
16| 118‐515937‐V| BATTERY & ANTENNA ENCLOSURE| 1
17| 041‐515972| SECONDARY BACKPLATE| 1
18| 033‐515996‐2| LOCK GASKET| 1
19| 810‐515193| SCREW 8‐32 x ½ PAN HEAD PHILLIPS| 2
Installation Steps
Install key cylinder (for MKO only)
- Insert the cylinder core in the key override housing.
- Secure the cylinder core (item 13) using screw item 13.
- Secure the access plate key cylinder item 14 over the key override housing.
- Secure the access plate using two screws item 15.
Install mounting option (for secondary backplate mounting only)
- If supplied with secondary backplate item 17, install gasket item 18 & secure secondary backplate item 17 into place using 3 screw items 9 & 1 screw item 11.
Install the lock spindle
The spindle must be installed and properly secured in the front lock housing
assembly. The spindle is used to connect the handle to operate the opening and
closing door mechanism.
Install the lock housing on the door
Before starting the installation of the lock on the door, please make sure the
door has been prepared properly with proper holes for the lock. Refer to
corresponding drilling template for your lock model. Drilling templates are
available in the centerfold included in this installation manual and on the
dormakaba support site
(dormakabalodgingsupport.com)
Install the housing on the door and align with the lock mechanism.
-
Install the front lock housing with gasket item 19, routing the wire cable(s) by the center hole at the top & in the groove.
-
Install the supplied adaptor plate and secure with 3 screw items 7.
OR -
If supplied with secondary backplate item 18, secure the housing into place using 4 binding barrels item 2 with 4 screw items 8.
Install exit device
- Please refer to exit device manufacturer installation manual.
- IMPORTANT
For rim and concealed mount exit devices, start with step 5.6 For surface mount exit devices, start with step 5.7
Connect the cables & install enclosure
- Connect each cable with its matching connector and route the excess of cable back into the hole of the door.
- Secure battery enclosure with 2 screw items 19.
- Insert the batteries in the battery holder respecting the polarity indicated in the battery holder.
- Reinstall cover with setscrew
Connect the cables & install enclosure (SVR ONLY)
IMPORTANT
All Surface vertical rods exit device require the use of DT‐516418‐15 After
final assembly, you must not be able to see cable groove.
- Connect each cable with its matching connector and route the excess of cable back into the hole of the door.
- Line up the enclosure in the same position as shown below with the supplied surface mount drilling template. Proceed to drill the screws into the door.
- Secure battery enclosure with 2 screw items 10
- Insert the batteries in the battery holder respecting the polarity indicated in the battery holder
- Reinstall cover with setscrew.
Install the outside lever handle
- Install the outside bushing item 1, making sure it is snug
- Install the outside lever handle according to the lock handing (LH/RH)
- Secure using set screw item 6.
IMPORTANT
Use only Alkaline batteries
Test lock functionality
Make sure the room door is open prior testing.
- A ‐ Present test keycard
- B ‐ Check green & red lights flash
- C ‐ Rotate outside lever to check bolt or rod(s) retraction D ‐ Release outside lever, should move freely
- E – Push panic bar to check bolt or rod(s) retraction
Program the lock
Refer to dormakaba access management system user manual for lock programming.
Think tomorrow
We are committed to championing sustainability in everything we do, from
producing more sustainable solutions to help our customers lessen their
environmental footprint to being a fair and responsible employer and neighbor.
- Customer Service
- KWSCustomerService.AMER@dormakaba.com
- Technical Support
- lodgingsupport@dormakaba.com
- www.dormakabalodgingsupport.com
- dormakaba USA Inc. 6161 E. 75th Street Indianapolis, IN 46250
- T: 1 800 849 8324 dormakaba.us
References
- dormakaba UK and Ireland | For every place that matters
- dormakaba USA | For every place that matters
- my.dormakaba
Read User Manual Online (PDF format)