CommScopeRC-1010-S Base Shoe Posts
Specifications
- Dimensions: 10’x10′
- Height: 135.9 inches
- Length: 130.0 inches
- Width: 126.3 inches
- Weight: 53.81 lbs (Base Shoe Weldment), 32.10 lbs (Outer Channel), 41.34 lbs (Canopy Center Channel), and more (refer to individual components)
Product Usage Instructions
General Notes
All metric dimensions are in brackets [X. X]. For patent info, visit
https://www.cs-pat.com.
Design Notes
Prior to installing the appurtenance, identify any hazards or obstructions
to the climbing facility and safety climb. Additional products may be required
to maintain integrity. During installation, take temporary and/or permanent
precautionary measures to preserve the climbing facility and/or safety climb.
Manufacturing/Special Requirements
Tighten all bolts securing flat plates by the turn-of-nut method. Tighten
all U-bolts using turn-of-nut method with attention to leave equal distance
and equal force on each leg of the U-bolt.
Packaging
Packaging shall meet CommScope requirements per document IS-PL-3005.
Printed document to be placed inside polybag and then in shipping container.
Extra hardware may be supplied, bagged, and shipped.
FAQ
-
Q: What is the weight capacity of the product?
A: The weight capacity of the product is not specified, but it is recommended to follow proper installation guidelines for safety. -
Q: Are installation tools included with the product?
A: No, installation tools are not included. Please refer to the provided list of component part numbers for assembly purposes.
GENERAL NOTES
- ALL METRIC DIMENSIONS ARE IN BRACKETS [X. X]
- FOR PATENT INFO: https://www.cs-pat.com
DESIGN NOTES
- ANY HAZARDS OR OBSTRUCTIONS TO THE CLIMBING FACILITY AND SAFETY CLIMB MUST BE IDENTIFIED PRIOR TO INSTALLING THE APPURTENANCE. ADDITIONAL PRODUCTS MAY BE
REQUIRED TO MAINTAIN THE INTEGRITY OF THE SAFETY CLIMB. DURING INSTALLATION, TEMPORARY AND/OR PERMANENT PRECAUTIONARY MEASURES SHOULD BE TAKEN TO PRESERVE THE CLIMBING FACILITY AND/OR SAFETY CLIMB.
MANUFACTURING/SPECIAL REQUIREMENTS
- TIGHTEN ALL BOLTS SECURING FLAT PLATES BY THE TURN-OF-NUT METHOD. TIGHTEN ALL U-BOLTS USING TURN-OF-NUT METHOD WITH ATTENTION TO LEAVE EQUAL DISTANCE AND EQUAL FORCE ON EACH LEG OF THE U-BOLT.
TEST
PACKAGING
- PACKAGING SHALL MEET COMMSCOPE REQUIREMENTS PER DOCUMENT IS-PL-3005
- PRINTED DOCUMENT TO BE PLACED INSIDE POLYBAG AND THEN IN SHIPPING CONTAINER
- EXTRA HARDWARE MAY BE SUPPLIED, BAGGED AND SHIPPED
GENERAL NOTES
COMPONENT PART NUMBERS PROVIDED FOR ASSEMBLY PURPOSES; INDIVIDUAL COMPONENTS MAY BE SHIPPED AS PARTS WITHIN AN INCLUDED KIT.
ITEM PART NO. DESCRIPTION QTY. WEIGHT NOTE NO.
1 | MF12601 | BASE SHOE WELDMENT,10′ 6″ | 4 | 53.81 LBS | |
---|---|---|---|---|---|
2 | MTC4130-7000-00 | OUTER CHANNEL, ROOF SUPPORT | 4 | 32.10 LBS | |
3 | MTC4130-8100-00 | CANOPY CENTER CHANNEL | 4 | 41.34 LBS | |
4 | RDR2636120 | ROOF DECKING PBR 26 GA 36″ X 120″ | 4 | 29.65 LBS | |
5 | MTC4130-3000-00 | CANOPY BRACE | 8 | 6.52 LBS | |
6 | MTC4130-4000-00 | CANOPY BRACE ADAPTER | 4 | 9.16 LBS | |
7 | MTC4130-5000-00 | PLATE, 7″X 5″ | 4 | 2.76 LBS | |
8 | MTC4130-6000-00 | HEIGHT ADJUSTMENT BRACKET | 2 | 1.26 LBS | |
9 | MTC4130-9000-00 | OUTER CONNECTION CHANNEL | 2 | 6.71 LBS | |
10 | GUB-4355 | 1/2″ X 3-5/8″ X 5″ GALV U-BOLT | 16 | 0.71 LBS | |
11 | GB-04145 | 1/2″ X 1-1/2″ GALV BOLT KIT | 20 | 0.13 LBS | |
12 | GB-03105 | 3/8″ X 1″ GALV BOLT KIT | 16 | 0.05 LBS | |
13 | GB-05205FT | 5/8″ X 2″ GALV BOLT KIT | 16 | 0.26 LBS | |
14 | GWF-04 | 1/2″ GALV FLAT WASHER | 36 | 0.04 LBS | |
15 | GWF-05 | 5/8″ GALV FLAT WASHER, 1.7OD | 12 | 0.06 LBS | |
16 | MTC3799C26 | CLIP, RDR PANEL | 40 | 0.05 LBS | |
17 | MTC371531 | 1/4-14X7/8 SELF DRILLING HEX HEAD SCREW | 100 | 0.02 LBS | |
18 | TS1275 | TEK SCREW #12 X 3/4, WITH NEOPRENE WASHER | 112 | 0.02 LBS | |
19 | MT-287 | 3/4″ ANCHOR BOLT | 8 | 1.08 LBS | |
4 | 3 |
HIDE ROOF DECKING FOR CLARITY