SCHLAGE 990MF Legge Omnia Smart Lock Instruction Manual

June 15, 2024
Schlage

SCHLAGE 990MF Legge Omnia Smart Lock

Specifications

  • Recommended lock: Legge 991MF or 990MF mortice lock
  • Door thickness: 35mm to 60mm

Product Usage Instructions

1. Preparing the Door

Measure and mark the door according to the provided dimensions. Note: Cylinder hole is not required unless using an extension kit.

2. Fasten Hexagonal Posts

Attach the hexagonal screw casings to the studs on the back of the external unit securely.

3. Adjust Spindle Holder Direction

Ensure the spindle holder arrow points in the correct direction based on the type of lock being used (mortice lock or latch).

4. Select Correct Length Screws and Spindle

Refer to the box contents to select the appropriate screws and spindle based on your door thickness.

5. Fasten External and Internal Units to Door

Securely fasten both units to the door, ensuring proper alignment and gasket placement.

6. Install Batteries

Use a screwdriver to open the battery cover, insert 4x AAA alkaline batteries, and then close the cover securely.

7. Test Operation

Test the operation of the lock by rotating the external and internal levers, ensuring proper latch bolt movement. Test the code functionality as well.

Care and Maintenance

  • Door Furniture: Check and tighten fixing screws annually. Clean with a soft damp cloth using mild detergent if needed.
  • Mortice Lock: Keep internal components clean. Lubricate tubular latches annually with an aerosol lubricant.

Warranty Information

Our goods come with guarantees under local consumer law. Refer to our website for detailed warranty information and exclusions.

FAQ

  • Q: How often should I check and tighten the fixing screws on the door furniture?
    • A: The fixing screws should be checked and tightened annually to ensure proper functionality.
  • Q: Can tubular latches be used in external situations?
    • A: Yes, tubular latches can be used externally but should be lubricated annually with an aerosol lubricant.

Box contents

Spindle, choose one set:

Fixing screws, choose one set

Recommended lock

  • Legge 991MF or
    • 990MF mortice lock

Door thickness

  • 35mm to 60mm

Tools required

  • Tape measure
  • Pencil
  • Level
  • Drill
  • Drill bit – 10mm
  • Spade bit – 22mm
  • Hammer
  • Chisel
  • Screwdriver (Phillips)

Scan here for more information on installing the Schlage Omnia Smart Lock

Installation Instruction

PREPARING THE DOOR

After preparing the mortice lock as per the instructions of the lock, drill a spindle hole Ø22mm. From the centre of spindle hole, measure a top fixing hole at 160mm and a bottom fixing hole at 85mm, drill Ø10mm fixing holes. Install mortice lock.

FASTEN HEXAGONAL POSTS

Attach the hexagonal screw casings to the studs on the back of the external unit

HANDING – EXTERNAL UNIT (AS REQUIRED)

Using a hex key, remove the holding screw from the lever. Remove the lever, rotate the lever 180° and reattach the lever. Reinstall the securing screw and tighten

HANDING – INTERNAL UNIT (AS REQUIRED)

Use a screwdriver to remove securing screws. Remove the lever, rotate the lever 180° and reattach the lever. Refasten the securing screws

ADJUST SPINDLE HOLDER DIRECTION

Ensure the spindle holder arrow points in the opposite direction of the lever when using a mortice lock. When using a latch, ensure the arrow points down

SELECT THE CORRECT LENGTH SCREWS AND SPINDLE

Refer to the front cover for box contents, to select the correct screws and spindles to suit your door thickness.

FASTEN EXTERNAL AND INTERNAL UNITS TO DOOR

Fasten units to the door, ensuring gasket is seated correctly.

INSTALL BATTERIES

Use a screwdriver to remove the battery cover. Install 4x AAA alkaline batteries. Resecure the battery cover.

TEST OPERATION

Rotate the external lever, ensure latch bolt does not retract (refer to step 5). Rotate the internal lever, ensure latch bolt does retract (refer to step 6). Test operation using code 123456#. Ignore Bluetooth administrator voice message when testing code

CARE AND MAINTENANCE

Door Furniture

At twelve (12) monthly intervals, the fixing screws securing the furniture to the door, both surface fix and through fix, should be checked and tightened as required. Loose fitting furniture which fails will not be covered under warranty. All door furniture should only be wiped clean with a soft damp cloth. A non-abrasive mild household detergent may be used to remove ingrained grime.

Mortice Lock

Care should be taken to ensure the internal components are kept free of dirt and woodchips during installation as this is the most common cause of malfunction and will not be covered under warranty. Tubular latches used in external situations should be lubricated by an aerosol lubricant at twelve (12) monthly intervals.

WARRANTY

Our goods come with guarantees that cannot be excluded under the local consumer law. You are entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The warranty does not cover any defect or damage which may be caused or partly caused if the goods are not properly maintained, installed or are not suitable to the specified application. Refer to our website for our finish warranty www.allegion.co.nz/finisheswarranty

SCHLAGE BREEZE APP

For an enhanced experience and additional functionality, we recommend you download the Schlage Breeze mobile app from the Apple App Store or the Google Play Store.

  1. Create a user account using your email address (or log in if you have an existing account).
  2. Ensure Bluetooth is enabled on your phone, tap the keypad of your Schlage Omnia lock to activate it.
  3. To pair the lock with the app, click on the + and follow the instructions on the app.

Contact