KONICA MINOLTA CM-16d, CM-17d Spectrophotometer User Guide

June 14, 2024
KONICA MINOLTA

KONICA MINOLTA CM-16d, CM-17d Spectrophotometer

Specifications

  • Product: Spectrophotometer

  • Models: CM-17d, CM-16d

  • Features: Vertical portable design, camera viewfinder (CM-17d), wireless connectivity

  • Measurement Time: CM-17d approx. 9.5s, CM-700d approx. 13s

  • Optional Accessories: Vertical Leveling Jig, Color Data Software SpectraMagic NX2

  • Additional Features: Wavelength Analysis & Adjustment (WAA), Cradle for charging and zero calibration

FAQs

  • Q: Is a wireless connection required for using the spectrophotometer?
    • A: A wireless connection is optional and requires the WLAN/Bluetooth module. A wired connection via cable is also possible.
  • Q: How can I access the Color Data Software SpectraMagic NX2?
    • A: The SpectraMagic NX2 software can be accessed by purchasing the optional software package. It enables colour management and data transfer functionalities.
  • Q: What is the purpose of Wavelength Analysis & Adjustment (WAA)?
    • A: WAA ensures higher-reliability measurements and minimizes system problems by analyzing and adjusting wavelength shifts. It is available free of charge for the first year after purchase.

OVERVIEW

Vertical portable spectrophotometer excellent for measuring small samples and curved surfaces

  • The CM-17d has a camera viewfinder for easy positioning.
  • The CM-16d is designed for simplicity and offers excellent cost performance.

Use

Simple to Configure and Ease of Use

Ergonomically designed to be easy to grip. It can be used in a wide range of measurement scenarios, including one-handed work, vertical orientation, and measurement of small objects and curved surfaces. The stress-free hardware design includes easy positioning with the camera viewfinder1, improved visibility with a slight tilt of the operation screen, and a comfortable workspace with wireless connectivity2.

  1. Camera viewfinder is a feature of CM-17d only.
  2. WLAN/Bluetooth module (option) is required.

Higher accuracy and shorter measurement time

  • The CM-17d has adopted a di:8°and de:8°integrating sphere compatible with the previous CM-700d series.
  • Along with the improved measurement accuracy of the black colour, the CM-17d also improves efficiency with shorter measurement times.

Various measurement examples utilizing optional accessories

  • The vertical levelling jig is useful when the main unit is turned upside down for measurement.
  • The tripod hole on the front of the body can also be used to hold the instrument in place.

Color Data Software SpectraMagic NX2 (Option)

  • SpectraMagic NX2 is colour management software that gives users a customizable screen display and a wide range of functions for operating and transferring data between their Spectrophotometer or Chroma Meter to their computer for further analysis.
  • Users can display data lists and create colour difference graphs and spectral graphs to assist in colour management that requires judgment based on numerous values and indicators.
  • WLAN/Bluetooth module (Option) is required for wireless connection. A wired connection via cable is also possible.
  • You can see the details in the catalogue from the following 2D code. SpectraMagic NX2 website.

Wavelength Analysis & Adjustment for high stability

  • WAA (Wavelength Analysis & Adjustment) provides worry-free, higher-reliability measurements and minimizes system problems by suppressing shifts in measurement.
  • WAA is available free of charge for the first year after purchase of the CM-17d series. After the second year, WAA can be continued as an add-on to the inspection and calibration service.

Cradle for charging and zero calibration

  • When not in use, the instrument can be placed on the Cradle* to charge the battery, and provide a safe stowage. Also serves as a zero calibration table, allowing calibration work to be performed while the unit is in place.
  • Standard accessories only for CM-17d

Try CM-17d with Augmented Reality.

  • Scan the 2D code to see product size and design on your iPhone.
  • You can only use it with an iPhone.
  • Please refer to the specifications for the dimensions of the product.
  • All the content copyrights belong to Konica Minolta, Inc.

CM-17d Series spectrophotometers can be used in a wide range of industries.

Spectrophotometer Configuration Tool CM-CT1 Ver.1.5 or later

The CM-CT1 gives manufacturers the means for easily and quickly setting up their spectrophotometers. Moreover, when multiple devices are used or when the same conditions need to be set amongst multiple factories or suppliers, settings can be compiled into a file and shared.

Easily unify measurement conditions and environmental settings amongst spectrophotometer

Spectrophotometer Configuration Tool

Spectrophotometer Configuration Tool CM-CT1

  • OS: Windows® 10 Pro 64 bit Version 1903 or higher/ Windows® 11 Pro
  • CPU: 2.0 GHz equivalent or faster
  • Memory: 2 GB or more
  • Hard disk: 10 GB or more of free space for installation
  • Other: USB port (For connecting to spectrophotometers and SpectraMagic NX2 dongle)
  • Windows® is a trademark or registered trademark of Microsoft Corporation in the USA and other countries.

System Diagram

Optional Accessories

  • Depending on the location, some accessories may not be available.
  • May be included as a standard accessory in some regions.

Specifications

  CM- 17d CM- 16d
Illumination/viewing system di:8°,de:8° (diffuse illumination: 8° viewing),

SCI (specular component included) / SCE (specular component excluded) switchable
Applicable standards for illumination/viewing system| Conforms to ISO7724/1, CIE No.15 (2004), ASTM E 1164 (SCI), DIN5033 Teil7, JIS Z 8722 Condition c standard
Integrating sphere| Ø40 mm
Detector| Dual 32-element silicon photodiode arrays
Spectral separation device| Planar diffraction grating
Wavelength range| 400 nm to 700 nm
Measurement wavelength pitch| 10 nm
Half bandwidth| Approx. 10 nm
Reflectance range| 0 to 175%; Resolution: 0.01%
Light source| Pulsed xenon lamp (with UV cut filter)
Measurement time| Approx. 0.7 s (Measurement mode: SCI or SCE, from pressing trigger button to measurement completion)
Minimum measurement interval| Approx. 1.5 s (Measurement mode: SCI or SCE)
Battery performance| Approx. 2,000 measurements (approx. 1,000 measurements when using Optional WLAN/Bluetooth module) when measurements are taken at 10-second intervals at 23°C with the dedicated lithium battery, without using camera viewfinder
Measurement area/ Illumination area| MAV:Ø8 mm/Ø11 mm SAV:Ø3 mm/Ø6 mm

*Can be changed by replacing the target mask and switching the lens position

| ****

MAV:Ø8 mm/Ø11 mm


Repeatability

| Standard deviation within ΔE*ab 0.02

(When a white calibration plate is measured 30 times at 5-second intervals after white calibration under Konica Minolta standard conditions)

| Standard deviation within ΔE*ab 0.04

(When a white calibration plate is measured 30 times at 5-second intervals after white calibration under Konica Minolta standard conditions)


Inter-instrument agreement

| Within ΔE*ab 0.12

(Based on average for 12 BCRA Series II color tiles; MAV SCI; compared to values measured with a master body under Konica Minolta standard conditions)

| Within ΔE*ab 0.2

(Based on average for 12 BCRA Series II color tiles; MAV SCI; compared to values measured with a master body under Konica Minolta standard conditions)

Display| 2.7-inch TFT color LCD with reversible portrait viewing mode
Internal performance check1| WAA (Wavelength Analysis & Adjustment) Technology
Interface| USB 2.0; WLAN (IEEE 802.11 b/g/n)/Bluetooth(Ver.4.1, SPP- compatible.) Optional WLAN/Bluetooth module required
2 3
Camera viewfinder function| Using internal camera; Images can be shown on display| —
Observer| 2° Standard Observer, 10° Standard Observer
Illuminant| A,C,D50,D65,F2,F6,F7,F8,F10,F11,F12,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5 ,LED-BH1,LED-RGB1,LED-V1,LED-V2,User-defined illuminant
4 (Max. 3 types)

(Simultaneous evaluation with two light sources possible)

Display items| Colorimetric values/graph, color difference values/graph, spectral graph, pass/fail judgment, pseudocolor
Color spaces| Lab, LCh, Hunter Lab, Yxy, XYZ, and color difference in these spaces; Munsell (C)
Indices| MI, WI (ASTM E313-73/ASTM E313-98);YI (ASTM E313-73, ASTM D1925);ISO brightness (ISO2470);WI/Tint (CIE);Tristimulus Strength;Opacity; Grey scale (ISO 105-A05);gloss value; User index
5, Blackness (My) (ISO18314-3/DIN55979);Jetness (Mc) (ISO18314-3);Undertone (dM) (ISO18314-3)
Color difference equations| ΔEab (CIE1976) ; ΔE94 (CIE1994); ΔE00 (CIEDE2000); CMC (l:c); Hunter ΔE; DIN99o; FMC-2;ΔE94 (Special)6
Data memory| 1,000 target data + 5,000 sample data


Power

| AC power supply| USB Type-C AC adapter (Power Delivery compatible, 15 W or more)
Battery| Lithium-ion battery (removable)
USB charging| USB bus power (with lithium-ion battery installed)
Charging time| Approx. 3.5 h (rapid charge) / Approx. 6 h(standard)
Size| Approx. 79(W)×230(H)×128(D) mm
Weight| Approx.700 g (Lithium-ion battery included) Approx.660 g (Lithium-ion battery included)
Operating temperature/ humidity range| Temperature: 5 to 40°C; Relative humidity: 80% or less (at 35°C) with no condensation
Storage temperature/ humidity range| Temperature: 0 to 45°C; Relative humidity: 80% or less (at 35°C) with no condensation

Dimensions

Dimensions (Units: mm)

  1. The WAA function enables wavelength diagnosis and wavelength correction of the instrument. This function is available free of charge for the first year after purchase and can be continued after the second year by having the instrument serviced and calibrated.
  2. Requires optional accessory WLAN/Bluetooth module (CM-A300).
  3. WLAN security supports WPA2-PSK (WPA2-Personal) and WPA-PSK (WPA-Personal) for the AdHoc method, and WPA3-PSK (WPA3-Personal), WPA2-PSK (WPA2-Personal) and WPA-PSK (WPA-Personal) for the Infrastructure method.
  4. Optional Color Data Software SpectraMagic NX2 Pro (Ver.1.3 or later) is required for setting user-configured illuminants.
  5. Spectrophotometer Configuration Tool CM-CT1 Ver. 1.5 or later and a valid Color Data Software SpectraMagic NX2 license are required for setting user indices.
  6. When comparing two colours, please use ΔE*94(Special) if one of them is not specified as the standard.
    • KONICAMINOLTA, the Konica Minolta logo and symbol mark, “Giving Shape to Ideas” and SpectraMagic are registered trademarks or trademarks of Konica Minolta, Inc.
    • Bluetooth® is a registered trademark of Bluetooth SIG, Inc. and is used under a license agreement.
    • iPhone® is a registered trademark of Apple Inc., registered in the U.S. and other countries.
    • Displays shown are for illustration purposes only.
    • The specifications and appearance shown herein are subject to change without notice.

SAFETY PRECAUTIONS

  • For correct use and your safety, be sure to read the instruction manual before using the instrument.
  • Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.

Konica Minolta Sensing Americas, Inc.| New Jersey, U.S.A.| PHONE: (888)473-2656 (in USA),| +1(201)236-4300 (outside USA)| FAX: +1(201)785-2480| E-Mail:| [email protected]
---|---|---|---|---|---|---
Konica Minolta Sensing Europe B.V.| European HQ/ BENELUX| Nieuwegein, Netherlands| PHONE:| +31(0)30 248-1193| E-Mail:| [email protected]
 | German Oice| München, Germany| PHONE:| +49(0)89 4357 156 0| E-Mail:| [email protected]
 | French Oice| Roissy CDG Cedex, France| PHONE:| +33(0)1 80 11 10 70| E-Mail:| [email protected]
 | UK Oice| Warrington, United Kingdom| PHONE:| +44(0)1925 467300| E-Mail:| [email protected]
 | Italian Oice| Cinisello Balsamo, Italy| PHONE:| +39 02849488.00| E-Mail:| [email protected]
 | Swiss Oice| Dietikon, Switzerland| PHONE:| +41(0)43 322-9800| E-Mail:| [email protected]
 | Nordic Oice| VÄSTRA FRÖLUNDA, Sweden| PHONE:| +46(0)31 7099464| E-Mail:| [email protected]
 | Polish Oice| Wrocław, Poland| PHONE:| +48(0)71 73452-11| E-Mail:| [email protected]
Konica Minolta (CHINA) Investment Ltd.| SE Sales Division| Shanghai, China| PHONE:| +86-(0)21-6057-1089| E-Mail:| [email protected]
 | Beijing Office| Beijing, China| PHONE:| +86-(0)10-8522 1551| E-Mail:| [email protected]
 | Guangzhou Office| Guangzhou, China| PHONE:| +86-(0)20-3826 4220| E-Mail:| [email protected]
 | Chongqing Oice| Chongqing, China| PHONE:| +86-(0)23-6773 4988| E-Mail:| [email protected]
 | Qingdao Office| Shandong, China| PHONE:| +86-(0)532-8079 1871| E-Mail:| [email protected]
 | Wuhan Oice| Hubei, China| PHONE:| +86-(0)27-6885 0586| E-Mail:| [email protected]
 | Shenzhen Office| Shenzhen, China| PHONE:| +86-(0)755-2868 7535| E-Mail:| [email protected]
 | Xiamen Oice| Xiamen, China| PHONE:| +86-(0)592-7107 399| E-Mail:| [email protected]
Konica Minolta Sensing Singapore Pte. Ltd.| Singapore|  | PHONE:| +65 6563-5533| E-Mail:| se- [email protected]
Konica Minolta Sensing Korea Co., Ltd.| Korean HQ| Goyang-si, Korea| PHONE:| +82(0)2-523-9726| E-Mail:| [email protected]

Addresses telephone/fax numbers and e-mail addresses are subject to change without notice.

For the latest contact information, please refer to the KONICA MINOLTA Worldwide Offices web page:https://konicaminolta.com/instruments/network. ©2024 KONICA MINOLTA, INC. 9242-AEEW-41 CEFDK

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KONICA MINOLTA User Manuals

Related Manuals