EXPERTPOWER SPLRM100 Monocrystalline Solar Panel Instruction Manual
- June 10, 2024
- ExpertPower
Table of Contents
EXPERTPOWER SPLRM100 Monocrystalline Solar Panel
Specifications
- Maximum Power at STC: 100W
- Operating Voltage (Vmp): 18.81V
- Operating Current (Imp): 5.32A
- Open Circuit Voltage (Voc): 22.2V
- Short Circuit Current (Isc): 5.6A
- Max System Voltage: 1000VDC
- Maximum Series Fuse Rating: 15A
Product Usage Instructions
-
Safety Precautions
WARNING: RISK OF DEATH AND/OR FATAL INJURY. Solar Panels generate direct current under sunlight, so handle exposed wires with caution. Ensure installation is in a secure environment, considering weather conditions and the safety of individuals nearby. Electric current poses a fire hazard, so avoid locations with flammable gases, vapors, or substances. -
Connection Order
Follow the specified connection order to set up the system properly: -
Step 1: Connect the Battery to the Solar Controller.
-
Step 2: Connect the Solar Panel to the Solar Controller.
-
Step 3: Connect the Inverter to the Battery and DC Load to the Controller.
-
Solar Array Connection Guide
- The solar panel has a front and back side for proper orientation during installation. Ensure correct alignment for optimal performance.
-
- The solar controller and other components should be connected according to the provided guide for efficient operation.
-
Additional Components
Make sure to integrate the storage battery and inverter into th system as per the connection order to enable proper functioning of the solar panel setup. -
Maintenance
Regularly inspect and clean the solar panels to ensure maximum efficiency. Check connections for any signs of wear or damage.
FAQ
-
Q: Can I connect multiple solar panels in series?
A: Yes, you can connect multiple panels in series to increase the overall power output of your system. However, make sure toadhere to the maximum system voltage limits and fuse ratings. -
Q: What should I do if my solar panel is not generating power?
A: Check the connections, ensure proper orientation towards sunlight, and inspect for any shading that might affect performance. If issues persist, consult a professional for troubleshooting.
For more information, visit www.ExpertPower.us
SPLRM100 MANUAL
MONOCRYSTALLINE SOLAR PANEL
ELECTRICAL DATA
- Maximum Power at STC………………………………. 100W
- Operating Voltage (Vmp)……………………………. 18.81V
- Operating Current (Imp) …………………………….. 5.32A
- Open Circuit Voltage (Voc) ………………………… 22.2V
- Short Circuit Current (Isc)………………………………5.6A
- Max System Voltage ………………………………1000VDC
- Maximum Series Fuse Rating………………………….15A
MATERIALS
- Solar Cell Type……………. Monocrystalline (7 x 7 in)
- Number of Cells…………………………….33 (11 x 3) Cells
- Dimensions ………………………… 35.43 x 22.83 x 1.18 in
- Weight …………………………………………………………………..12.6 lbs
- Solar Connectors…………………………………………….MC4
- Application Class ……………………………………….Class A
- Fire Rating …………………………………………………. Class C
SOLAR ARRAY CONNECTION GUIDE
WARNING
- RISK OF DEATH AND/OR FATAL INJURY
- Solar Panels generate direct current under sunlight, be careful when handling exposed wires. Ensure installation is in a secure environment, be mindful of weather and those around you. Electric current poses a fire hazard, avoid areas with flammable gases, vapors, or other flammable substances.
CONNECTION ORDER
- Step 1: Battery to Controller
- Step 2: Solar Panel to Controller Step 3: Inverter to Battery / DC Load to Controller
References
Read User Manual Online (PDF format)