PBMS Tools Instructions

In order to connect your EP48100 to a computer to monitor it with PBMS Tools you will need the following materials:

  • USB to RS485 converter
  • Cat5/Cat6 Cable
  • RJ45 Connector
  • Wire stripper with 24 gauge opening
  • RJ45 crimper
  • BMS Tools Software

Alternatively:
ANSI/TIA-568B RJ45 Cat5/Cat6 premade cable

If you plan to make your own cable, you will need to crimp the Cat5/Cat6 cable in the ANSI/TIA-568B Standard to the RJ45 connector and the five-pin connector on the RS485 side in the following order, leaving the mid pin empty.
PBMS Tools Instructions

PBMS Tools Software

Open BmsTools.exe
PBMS Tools Instructions

This is how the program looks.
PBMS Tools Instructions

From the dropdown menu, change ADR_ Start to 1.
PBMS Tools Instructions

Click Open.
PBMS Tools Instructions

You may now monitor your EP48100 Battery.