GNB LAB ALL505881 ALLELUX Xmax UV LED Lamp User Manual
- June 3, 2024
- GNB LAB
Table of Contents
GNB LAB ALL505881 ALLELUX Xmax UV LED Lamp
ALLELUX XMAX UV / LED LAMP
Technical data
Power supply:
rated input: 100-240V, 50-60Hz rated output: DC24V
Power: 168W
Number of UV LEDs: 48pcs
UV wavelength: 365 + 405nm
Model: X MAX
Certificate No .: MOSTCN19081612 Cures hybrids / UV / LED gels.
Description of elements
- Infrared motion sensor
- LCD display
- Timer 30s
- Timer 60s
- Timer 90s
- Timer 120s (no pain mode)
- Power adapter connector
User manual
- Connect the device to the power supply.
- To turn on the lamp, press the timer button – you can choose one of the available timer options 30s / 60s / 90s / 120s, or start working without selecting a time. To do this, put your hand into the device, and the irradiation will start automatically when motion is detected by the sensor (exposure limit is 120s).
- The 30s / 60s / 90s timer buttons are equipped with a time saving function. Press and hold the button for about 2s to set the function, then press and hold for 2s or press another timer button to clear the memory.
- After connecting the power supply, the default lamp power is 54W. Press and hold the 120s timer button for 2s to change the power, then press and hold the timer button for 2s to return the power to 54W.
- The display shows the exposure time remaining. When using the timer 30s / 60s / 90s will count down. When using the 120s timer and starting the device using the motion sensor, the device counts up.
- Follow the curing instructions for the product used.
- After using the lamp, disconnect it from the mains.
Warnings:
- The lamp should only be supplied from a suitable power source.
- Protect the device from contact with dust, water and other liquids.
- Disconnect the lamp from the power source when the lamp is not in use or when the lamp needs cleaning.
Do not use the lamp
- In damp rooms.
- If the AC adapter has been damaged.
- If the device or the connecting cable is damaged.
- If the timer buttons do not work.
- The device should not be left running for more than 60 minutes, as this may reduce its service life. The device is intended for indoor use.
- It is forbidden to make independent switching and changes to the device.
- Opening the camera is strictly forbidden and will void the warranty, and the manufacturer is not responsible for the correct and safe operation of the device.
- Do not look directly at the UV light as it may damage the eyes. The lamp uses UV / LED diodes which emit dangerous UV rays. They can also damage the skin. The skin may be more sensitive to UV rays when taking medications or using cosmetics. If you notice any sudden changes in your skin, see your doctor immediately.
- KEEP AWAY FROM CHILDREN.
IMPORTER
GNBLab
Michał Szewczyk, Piotr Malinowski s.c Piotrkowska 270
90-361 Łódź, Polska gnb-lab.com
Made in P.R.C.