PROmesh B8 8-Port PROFINET And Ethernet IP Managed Switch User Guide

June 13, 2024
PROmesh

PROmesh B8 8-Port PROFINET And Ethernet IP Managed Switch

PROmesh-B8-8-Port-PROFINET-And-Ethernet-IP-Managed-Switch-
PRODUCT

Product Information

DEUTSCH ENGLISH
Spannungsversorgung Voltage Supply
Max. Stromaufnahme Max. Current Consumption
Max. Leistungsaufnahme Max. Power Consumption
Abmessungen (H x B x T) Size (H x W x D)
Gewicht Weight
Montageart Mounting
Schutzart Protection Class
Lagertemperatur Storage temperature
Betriebstemperatur Operating temperature
Luftfeuchtigkeit, relativ Relative Humidity
Port Mirroring Port Mirroring
PROFINET Standard PROFINET standard
PROFINET Conformance Class PROFINET Conformance
PROFINET Netload Class PROFINET Netload Class
Datenports Data Ports
Switching Mode Switching Mode
Diagnose & Management Diagnosis & Management

Product Usage Instructions

  1. Check the PROmesh B8 compact for any external damage before putting it into operation.

  2. Make sure to observe the technical specifications of the device for safe and optimal use.

  3. The PROmesh B8 compact is designed for IP20 protection environments. Take appropriate measures to ensure proper operation of the unit in a different environment.

  4. If you suspect any damage to the PROmesh B8 compact, please return it immediately to your supplier and do not put it into operation.

  5. To configure the network connection, download the ServiceTool software to your client PC (Windows) from the following link:
    https://sdx.indu-sol.com/s/HiftDTLpYLbCEoS

  6. After assigning a suitable IP address and subnet mask, the web UI of the PROmesh B8 compact will be accessible.

  7. The PROmesh B8 compact comes with the following factory settings:

    • IP Address: 0.0.0.0
    • Subnet Mask: 0.0.0.0
    • Gateway: 0.0.0.0
    • Username: admin
    • Password: admin
  8. To interpret the LED indicators:

    • VDC1 Status LED: Off – Sufficient voltage at the connection; On – Insufficient voltage at the connection
    • Error Status LED: On – Active PROFINET connection to the controller; Off – No PROFINET connection to the controller
    • Port status LED: Blinking – Port is in network communication exchange; Off – No power outage, no port error, and no configured alarm

All accompanying materials of the product can be found at:
https://sdx.indu-sol.com/s/HiftDTLpYLbCEoS

General Notes

WARNING
Commissioning and operation of this device may be carried out by qualified personnel only. Qualified personnel are persons who are authorized to commission, ground and label devices, systems and circuits in accordance with the standards of safety engineering.

Something‘s wrong with your product?
You can reach our technical support team on weekdays between 07:30 am – 04:30 pm (CET) by telephone: +49(0)34491 / 580-321 or send us an e-mail: support @indu-sol.com. We will get in touch with you promptly.

Your system is at a standstill?
Reach out to our emergency service even outside our regular opening hours: +49(0)34491 / 580-0.

Device Connections

Power SupplyPROmesh-B8-8-Port-PROFINET-And-Ethernet-IP-Managed-Switch-
FIG- \(2\)

Technical Data

Voltage Supply 24 VDC
Max. Current Consumption 0,8 A
Max. Power Consumption 8W
Size (H x W x D) 100 x 50 x 60 mm
Weight 350 g
Mounting 35 mm DIN rail
Protection Class IP20
Storage temperature -10°C … 60°C
Operating temperature -10°C … 60°C
Relative Humidity 5% .. 95%, RHD non-condensing
PROFINET Conformance Class B
PROFINET standard PROFINET 2.4
Port Mirroring Rx, Tx+Rx
PROFINET Netload Class Class III
Data Ports 8x 10/100 MBit/s RJ45
Switching Mode Store & Forward
Diagnosis & Management Network load monitoring Port-Mirroring

DCP, I&M

SNMPv1, v2c, v3

General Information

The PROmesh B8 compact is a full-managed Ethernet/PROFINET switch for industrial automation systems which can be easily and conveniently configured via a web UI. It enables uncomplicated installation of bus, star and ring structures with switching functionality

Safety Instructions
Before putting the PROmesh B8 compact into operation, check whether it is inperfect condition externally. Always observe the technical specifications of the device to ensure safe and optimal use. The PROmesh B8 compact is designed for IP20 protection environments. Take appropriate measures to ensure proper operation of the unit in a different environment

WARNING

In case of suspected damage, please return the PROmesh B8 compact immediately to your supplier and do not put it into operation.
Do not open the housing under any circumstances. Unauthorized opening of the housing will void any warranty claims.
The PROmesh B8 compact is designed for use in PROFINET applications according to Conformance Class B.
For complete support of the PROFINET standards, please also observe the selection, layout and wiring of the data ports according to these standards.

  • PROmesh B8 compact
  • 3-pole 5 mm terminal block (power supply)
  • Quickstart User Guide (hardcopy)

Mounting on the DIN Rail

Mount the PROmesh B8 compact upright in the switch cabinet on a 35 mm DIN rail (DIN EN 60715).
NOTE
The following distances to other modules must be observed:

  • right / left: 50 mm
  • top / bottom: 20 mm

WARNING
Do not mount the PROmesh B8 compact directly next to devices that generate strong electromagnetic interference fields or constantly emit heat to their surroundings. Also protect the PROmesh B8 compact from intense sunlight

Power Supply

  • The PROmesh B8 compact is operated with a voltage of 24 VDC, Connect a suitable power source to the labeled terminals of the 3-pin 2,5 mm2 terminal block. Connect the positive lead to one of the VDC contacts and the ammunition lead to the corresponding GND contact.
  • If the external power supply is correctly connected and activated, all status LEDs of the PROmesh B8 compact will light up briefly. After a short initialization phase the LEDs go out and the device is ready for operation and can now be configured in the network.

Configuring a Network Connection
Download the Service Tool to your client PC (Windows). You can find the software at the following link: https://sdx.indu-sol.com/s/HiftDTLpYLbCEoS

NOTE

  • Our software is updated regularly. Please, make sure you are using the latest version.
  • Connect the PC to a suitable data line on one of the data ports (P1 – 8).
  • The PROmesh B8 compact and the client PC must be located in the same IP address range and IP subnet. For this you have to assign a corresponding IP address to your PROmesh B8 compact for the first time. Use the already installed ServiceTool.
  • After assigning a suitable IP address and subnet mask, the Web UI of the PROmesh B8 compact can be reached.

The PROmesh B8 compact is delivered with the following factory settings:

IP Adress 0.0.0.0
Subnet mask 0.0.0.0
Gateway 0.0.0.0
Username admin
Password admin

After successful installation and start of the software, you can scan the system with the search setting PROFINET-Gerät. The PROmesh B8 compact is displayed in the search result. You can then make and save individual entries in the input mask.

NOTE
Make sure that the IP address you selected has not yet been assigned. If required, you can display IP addresses that have already been assigned using the PROscan® Active V2 license software from Indu-Sol.

WARNING
When logging in for the first time, you must change the factory-set password. It is your responsibility to document this password and protect it against unauthorized access

Accessing the Web User Interface
The device-specific functions of the PROmesh B8 compact can be configured via an integrated Web-UI. Open your browser, enter the IP address of the PROmesh B8 compact configured in the ServiceTool in your browser bar or use the above configuration data. Alternatively, you can right-click on the corresponding list entry in the context menu of the ServiceTool to select „to website“.
The Web UI now opens in your standard browser.

NOTE
Further information on the configuration options and troubleshooting can be found at the following link:
https://sdx.indu-sol.com/s/HiftDTLpYLbCEoS

Interpreting LED Displays

LED label Mode Meaning
VDC1 Green Voltage at terminal sufficient
Off Voltage at terminal insufficient
Status Green Active connection to the PROFINET controller
Yellow No active connection to the PROFINET controller
Error Red Power failure, port error or configured alarm active
Off No power failure, no port error and no confi- gured alarm active
Port Status On The port has established a valid network connection
Flashing The port is in network communication exchange
Off The port has not established a valid network connection

Indu-Sol GmbH Blumenstraße 3 04626 Schmoelln Germany
Telephone : +49 (0) 34491 580-0
Telefax : +49 (0) 34491 580-499
[email protected]
www.indu-sol.com
Certified according to DIN EN ISO 9001:2015

Version 1.0
Date: 23.06.2023
Product Code: 114110520
Printed in Germany
This document is subject to change without notice.
© Copyright 2023 Indu-Sol GmbH

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>