70MHz, 100MHz and 150MHz bandwidth, 2 or 4 analog channels
1 GSa/s real-time sample rate
14Mpts or 28Mpts memory depth
Up to 80,000wfm/s waveform capture rate
Up to 5 hours optional Li-ion battery (Options)
8″TFT LCD & 800*600 pixels high resolution Multi-touch capacity screen
Support serial bus trigger and decoding UART, I2C, SPI, CAN and LIN(Options)
Gradient waveform display with 256 intensity levels
7 types of trigger function: Edge, Pulse, Logic, Time Out, Runt, Slope, N Edge, and Video
Built-in 8G storage capacity, waveforms and screenshots can be viewed and edited in scope
Various 1/0 port, LAN, Wi-Fi, USB2.0, USB Device, HDMI, Trigger out
Support Android and iOS Application and PC software ware remote control

Innovation, makes test simpler.

Compared with traditional oscilloscope, Micsig tablet oscilloscope will bring you new operation experience and it will make your test and measurement work simpler & easier.

Micsig tBook mini TO1000 series is an entry level digital oscilloscope that will meet your requirements for excellent performance at an ultra-low price point. A portable and sleek design saves previous space on your workbench. Using high resolution multi-touch capacitive screen with intuitive menus, the TO1000 series is engineered to deliver a truly state-of-the-art experience.

Specification

Features and benefits

Optional software accessories

graphical user interface

Specifications

Horizontal system

Time base range: 2ns/div to 1 ks/div
Time base delay range: -14 divisions to 14ks
Clock skew: <±2ppm/Year
Time based accuracy: ±20ppm

Vertical system

Bandwidth limitation: 20MHz(TO1072/TO1074) 20MHz high pass, low pass(TO1102/TO1104/TO11 52)
Input coupling: DC, AC, GND
Input impedances: 1 M ±1 %!114.5pF±3pF
Vertical resolution: 8bits
DC gain accuracy: < ±2% ( 1 M **)
Vertical scale: 1 mV/div to 1 0V/div ( 1 M )
Channel to channel: 2’40dB ( 100:1 )
Offset range: ±6div
Maximum input voltage:** CAT I 300V ( 1MO)

Sampling system

Sampling mode Real time sample rate

Peak sampling
Sample rate 1 G Sais| All the sampling glitches in scanning rate are narrow to single channel 1 ns, dual channel 2 ns. four channel 4ns
Max duration in the max sampling rate
Sample rate 1 G Sais
Sample rate 500MSa/s
Sample rate 250MSa/s
Average| 28/14ms
56/28ms
56/28ms
Average of sampling for N times N is chosen from 2, 4, 8, 16, 32, 64, 128, 256
Envelope| Envelope of sampling for N times N is chosen from 2, 4, 8, 16, 32, 64, 128, 256, 00

Trigger system

Trigger mode: Normal, Auto, Single
Trigger coupling: DC, AC, HF reject( >50KHz ), LF reject( <50KHz }, noise reject
hold off range: 200ns to 10s
Trigger type
Edge: Positive, negative, or either slope on any channel input. Coupling includes DC, AC, HF reject, LF reject, and noise reject
Pulse Width: Trigger on width of positive or negative pulses that are > . < . =. “# , or inside/ outside a specified period of time (8ns~10s).
Logic: Trigger when any logical pattern of channels goes false or stays true for specified period of time (8ns~10s). Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND, OR, NANO, NOR) specified for all input channels defined as High, Low, or Don’t Care
Video trigger: Trigger on all lines or individual lines, odd/ even or all fields on PAL/625 SECAM, NTSC/525, 720P, 10801, 1080P video signals.
Time out: Trigger on an event which remains high, low, oreither, for a specified time period. Selectable from
Slope: Positive slope (Great than, lower than, within specific interval)
Negative slope (Great than, lower than , within specific interval)
Runt: Trigger on a pulse that crosses one threshold but fai ls to cross a second threshold before crossing the first again. Event can be time- or logic qualified.
Nth edge: Edge type: Risingm Falling Idle time: 16ns to 4s Number of edges 1 to 65535

Waveform measurement

Cursor: Horizontal Cursor, Vertical Cursor, Cross Cursor
Auto measurements: 23, of which up to five can be displayed on-screen at any one time. Measurements include: Period, Frequency, Rise Time, Fall Time, Delay, Positive duty Cycle, Negative Duty Cycle, Positive Pulse Width , Negative Pulse Width, Burst Width, Positive Overshoot, Negative Overshoot, Phase, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS.
Waveform math
Dual Waveform FFT: Add, subtract, multiply, and divide waveforms
FFT: Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman Harris.

Display system

Display type 8” TFT LCD Multi point capacitive screen
Display resolution 800*600
Max touch point on touch screen 5 points
Operation way Full touch. Mouse
Afterglow time Auto, 10ms to 10s, ∞
Time Base format YT, XY, Roll, Zoom
Expansion bench mark Center, Trigger Position
Waveform display Brightness is adjustable, point, Line
Grid 14*1 0 div, Brightness of the grid is adjustable
Grey level 256 level
Language English. Simplified Chinese. For more languages please contact

Micsig

Storage

Storage media Native, U Dis
Built-in memory 8G
Storage format csv,wav,bin
Waveform quantity Unlimited
waveform storage name Support
display the reference waveform quantity 4 piece
screenshot Support
User setting number storage Unlimited
User name setting Support
Flash format Comply with industry standards

Power source

Power source voltage 100 to 240V AC, 50/60Hz
Power consumption < 60W
Fuse 12V DC, 5A
Battery (Optional) 7.4V 8000mAH Lithium battery

Interface

USB Host Support USB mass storage devices, support read and write
USB Device Support read and write
DC interface For charging
Probe calibration Port 1KHz, 2Vpp
LAN Support
HDMI Optional
Wi-Fi Support

Environment

Temperature
Operating Non-operating| 0°c to 45°c
-40°c to 60°c
---|---
Humidity
Operating Non-operating| 5% to 85%, 2s0 c
5% to 90%, 2s0 c
Altitude
Operating
Non-operating| < 3000m
< 12000m

Physical characteristics

Dimensions
Height
Width
Depth| 200mm
250mm
55mm
---|---
Weight
Net
2CH Bare
4CH Bare
Shipping
4CH Bare
2CH Bare| 040g

1125g

2445g

2630g

Battery| 263g

Ordering information

  Description Order Number
Model TO1152 (150 MHz, 2 CH)

TO1104 (100 MHz, 4 CH)
T01102 (100 MHz, 2 CH)
TO1074 (70 MHz, 4 CH)
T01072 (70 MHz, 2 CH| TO1152
TO1104
TO11 02
TO1074
TO1072
Standard Accessories| Tablet Oscilloscope! Book Mini
Localized power cord
Power adapter
Probes (quantity depends on the oscilloscope channel)
BNC cap| See model
MS-Cable
MS-PA-1205
MS-PR-P1 30A
MS-Cap
Hardware Optional Accessories| ! Book mini battery
Carry strap Screen
Protector Film
Oscilloscope Handbag| MS-BA
MS-Belt
MS-Mask
MS-Handbag
Software Optional Accessories| HDMI+ HDMI cable
Serial bus decode: UART, CAN, LIN, SPI, I2C| MS-HOM!
MS-decode
Warranty| Repair Service 3 Years (including warranty)
Probes and accessories are not covered by the oscilloscope warranty and service offerings.
Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.|

Contact us

Micsig-logo Shenzhen Micsig Instruments Co., Ltd.
Micsig®   Tel: +86-755-86-88600880 Fax : +86-755-26078507-818
Web: www.micsig .com E-mail: sales@micsig.com
Add: 305 Block A , CLOU Building, Baoshen RD, North Area,
Nanshan Science& Technology Park .Shenzhen , Guangdong, China. 518000

Micsig Tablet Oscilloscope tBook Mini TO1000 Series User Manual – Download [optimized]
Micsig Tablet Oscilloscope tBook Mini TO1000 Series User Manual – Download

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals