Thank you for choosing a payment terminal Ingenico.
We recommend you to read carefully this installation guide : It gives you the
necessary information about safety precautions, unpacking, installation, and
maintenance of your terminal.
WARRANTY / SECURITY
To benefit from the guarantee- related product, and to respect the security, we ask you to use only accessories delivered in box with the product, entrusting maintenance operations only to an authorized person.
The OPEN1500 or OPEN2500 can be powered by different sources please respect these recommendations :
-
The power sources should comply with Standards IEC60950-1:2013
Edition 2.2 and EN60950-1:2006 + A11/2009 + A1/2010 + A12/2011 + A2:2013. Moreover, they should be Safety Extra-Low Voltage circuits and Power Limited Sources according to clauses 2.2 and 2.5 of these standards. -
The power source should be powered thanks to socket-outlets installed near the equipment and easily accessible.
-
OPEN power ratings : 12 – 24 V max 2A or POE 48 V 13W
Nota : Failure to comply with these instructions will void the manufacturer’s responsibility.
**** This symbol indicates an important Warning.
Recommendation
Safety
Power on / Power down
To power on or power down the OPEN connect or disconnect the cable connected to power plug.
Lithium battery
The OPEN is fitted with a lithium battery which is not accessible to the user.
Only a qualified technician may be authorized to open the unit and change this
component.
For switzerland annex 2.15 of SR 814.81 applies for batteries.
SAM, µSD connectors
They are operator accessible parts.
This is an Electrostatic (ESD) sensitive area and ESD precautions must be
taken when fitting it As a minimum, the operator should be “Electrostatically
Discharged” via his/her hand to a suitable safe metallic earthing point prior
to opening this area.
Connections to external equipment and circuits
All external circuits and equipment connected to the OPEN Reader should be Safety Extra-Low Voltage circuits according to clause 2.2 of Standards IEC60950-1:2013 Edition 2.2 and EN60950-1:2006 +A11/2009 + A1/2010 + A12/2011
- A2:2013.
Operating conditions
Temperature -20°C to +70°C (Consumer version) -20°C to +55°C (Automotive and Railway version)
Security of your terminal
Your device fulfils current applicable PCI PTS security requirements. Upon
receipt of your terminal you should check for signs of tampering of the
equipment. It is strongly advised that these checks are performed regularly
after receipt. You should check, for example : that the keypad is firmly in
place; that there is no evidence of unusual wires that have been connected to
any ports on your terminal or associated equipment, the chip card reader or
any other part of your terminal.
Such checks would provide warning of any unauthorised modifications to your
terminal, and other suspicious behaviour of individuals that have access to
your terminal. Your terminal detects any “tampered state”. In this state the
terminal will repeatedly flash the message” Alert Irruption!” and further use
of the terminal will not be possible. If you observe the
“Alert Irruption!” message, you should contact the terminal helpdesk
immediately.
You are strongly advised to ensure that privileged access to your terminal is
only granted to staff that have been independently verified as being
trustworthy.
The terminal must never be put in or left at a location where it could be
stolen or replaced by another device.
Integration
See installation guide.
Approvals and markings
warning marking which indicates the mandatory need to read the instructions
Mandatory conformity marking for products sold within the European Economic Area (EEA). It states that the product is assessed before being placed on the market and meets EU safety, health and environmental protection requirements
Indicates that the product has been certified to applicable standards
including standards written or administered by the American National Standards
Institute (ANSI),
Underwriters Laboratories (UL), CSA Group (CSA), NSF
International (NSF), and other North American and global Organizations.
Indicates that when the end-user wishes to discard this product, it must be sent to separate collection facilities for recovery and recycling.
Indicates that the product operates with a continuous voltage. This symbol is followed by the ratings (voltage and current for instance).
IC statements
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
“This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions :(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
FCC statement
FCC standard compliance marking certifies that the product stipulated below : OPEN
- conforms to the following harmonized standards :
part 15 subpart B of the FCC rules
This class (B) digital apparatus complies with Canadian ICES-003.
Information to users :
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more ofthe following measures :
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
This device complies with FCC and IC radiation exposure limits set forth for
general population. This device must be installed to providea separation
distance of at least 20cm from all persons and must not be co-located or
operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Maintenance
ATTENTION
Before making any operations of maintenance in the terminal, make sure that
power supply is disconnected.
Cleaning of the terminal
First of all, unplug all the wires from the terminal.
Good rules for proper cleaning of the terminal are :
- Use a soft cloth that is very slightly soaked with soapy water
- to clean the outside of the terminal.
- Do not clean the electrical connections.
- Do not use in any case, solvents, detergents or abrasive
- products : Those materials might damage the plastic or electrical contacts.
- Avoid exposing the terminal to the direct rays of the sun.
Transport and storage
- Use the original packaging for any unit transported or stored
- Disconnect all cables from the terminal during the transport.
Environment (WEEE, Bateries and packaging)
This product is labeled in accordance with European Directives 2012/19/ EU concerning Waste Electrical and Electronic Equipment (WEEE) and 2006/66/EC concerning Batteries and Accumulators. Those provisionsare requiring producers and manufacturers to become liable for takeback, treatment and recycling upon end of life of equipment and batteries.
The associated symbol means that WEEE and waste batteries must not be thrown
away but collected separately and recycled.
Ingenico ensures that efficient collection and recyclingschemes are set-up for
WEEE and batteries according to the local regulation of your country. Please
contact your retailers for more detailed information about the compliance
solution in place for disposing of your old product and used batteries.
Packaging waste must also be collected separately to assure a proper disposal
and recycling.
Please note that proper recycling of the electrical and electronic equipment
and waste batteries will ensure safety of human health and environment.
“This Document is Copyright © 2022 by INGENICO Group. INGENICO retains full copyright ownership, rights and protection in all material contained in this document. The recipient can receive this document on the condition that he will keep the document confidential and will not use its contents in any form or by any means, except as agreed beforehand, without the prior written permission of INGENICO. Moreover, nobody is authorized to place this document at the disposal of any third party without the prior written permission of INGENICO. If such permission is granted, it will be subject to the condition that the recipient ensures that any other recipient of this document, or information contained therein, is held responsible to INGENICO for the confidentiality of that information.
Care has been taken to ensure that the content of this document is as accurate as possible. INGENICO however declines any responsibility for inaccurate, incomplete or outdated information. The contents ofthis document may change from time to time without prior notice, and do not create, specify, modify or replace any new or prior contractual obligations agreed upon in writing between INGENICO and the user.
INGENICO is not responsible for any use of this device, which would be non consistent with the present document.
All trademarks used in this document remain the property of their rightful owners.”