nVent RAYCHEM C25-100-METAL Metal Connection Kit Instruction Manual

June 9, 2024
nVent RAYCHEM

nVent RAYCHEM C25-100-METAL Metal Connection Kit

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-product-
image

Product Information: Connection Kits for nVent RAYCHEM Heating Cables

The nVent RAYCHEM connection kits, namely C25-100-METAL and C3/4-100-METAL, are designed for use with all nVent RAYCHEM BTV-, QTVR-, XTV-, KTV-, HTV-, VPL-, and FHP-heating cables. These connection kits come with a C1 core sealer that must be installed inside an Ex equipment certified enclosure to prevent electrical shock, short circuit or arcing. These kits are certified for use in hazardous environments and come with several safety warnings and usage instructions.

Usage Instructions
  1. Read the installation instructions completely before installing the connection kit.
  2. Ensure that persons involved in the installation and testing of electric heat tracing systems are suitably trained in all special techniques required.
  3. Installation shall be carried out under the supervision of a qualified person.
  4. The purchaser should make the manufacturer aware of any external effects or aggressive substances that the equipment may be exposed to.
  5. Position gland components and grommet on the heating cable in order shown.
  6. Preinstall braid into braid clamp assembly as follows: Slide cone over inner jacket, spread braid over cone and slide clamp ring over braid and cone. Tighten middle body onto entry body (without grommet) using two spanners to securely lock braid between cone and clamp ring.
  7. Undo entry body and middle body assembly, remove entry body and slide nylon compression ring as well as grommet onto inner jacket. Replace entry body.

It is important to follow these instructions carefully to ensure the safe installation of the nVent RAYCHEM connection kits and prevent any accidents or hazards.

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-1

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-2

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-3

C25-100-METAL C3/4-100-METAL
Baseefa16ATEX0039U
BAS21UKEX0505U
IECEx BAS 16.0042UII 2 G Ex eb IIC Gb or Ex db IIC GbII 2 D Ex tb IIIC Db
ТС RU C-BE.МЮ62.В.00054/18
Ex e IIC Gb U Ex tb IIIC Db U
Ta –60°C…+180°C IP68
ООО “ТехИмпорт”

Installation instruction for connection kits nVent RAYCHEM C25-100-METAL and C3/4-100-METAL. For use with all nVent RAYCHEM BTV-, QTVR-, XTV-, KTV-, HTV-, VPL- and FHP-heating cables.
Before installing this product, read the installation instructions completely.

CAUTION: Prolonged or repeated contact with the sealant in the core sealer may cause skin irritation. Wash hands thoroughly. Overheating or burning the sealant will produce fumes that may cause polymer fume fever. Avoid contamination of cigarettes or tobacco. Consult MSDS VEN 0033 for further information.

WARNING: To prevent electrical shock, short circuit or arcing, this product must be installed correctly and water ingress must be avoided before and during the installation.
Persons involved in the installation and testing of electric heat tracing systems shall be suitably trained in all special techniques required. Installation shall be carried out under the supervision of a qualified person
The purchaser should make the manufacturer aware of any external effects or aggressive substances that the equipment may be exposed to.
The cable glands shall only be used for fixed installations. The cables must be fixed to prevent pulling or twisting.

Schedule of Limitations:
The service temperature of the C25-100-METAL / C3/4-100-METAL connection kit is –60°C to +180°C. When the C25-100-METAL / C3/ 4-100-METAL connection kit is used, it shall be mounted to an enclosure in accordance with the manufacturer’s instructions.
The installer is to carry out a dielectric strength test on the Ex equipment in which the C25-100-METAL / C3/4-100-METAL connection kit is fitted. No dielectric breakdown shall occur. (Alternatively an insulation resistance test may be undertaken in accordance with EN 60079-30-2). The integral C1 core sealer shall be installed inside an Ex equipment certified enclosure.

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-4

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-45

Position gland components and grommet on the heating cable in order shown.

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-8

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-10

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-11

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-12

Preinstall braid into braid clamp assembly as follows:
Slide cone over inner jacket, spread braid over cone and slide clamp ring over braid and cone. Tighten middle body onto entry body (without grommet) using two spanners to securely lock braid between cone and clamp ring.

Undo entry body and middle body assembly, remove entry body and slide nylon compression ring as well as grommet onto inner jacket. Replace entry body.

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-16

Remove the tubes and dispose of them in the core sealer plastic bag.

Trim bus wires. For length X see table.

Installation of the gland in the enclosure.
Conditions for threaded and unthreaded holes

| Threaded Holes| Unthreaded (through) holes
---|---|---
Tolerance Class| (6H) is required for Ex d and recommended for Ex e is max 6G/6H. Ref. ISO 965-1 and ISO 965-3.| Nominal thread size
M25 –0,0 mm/ +0,7 mm (M).


Enclosure Material Limitations

| Brass glands should not be installed in zinc or aluminium enclosures outdoor or in humid environments.| Brass glands should not be installed in zinc or aluminium enclosures outdoor or in humid environments.
Enclosure interface sealing method| If the sealing surfaces are uneven, use PTFE washer NFWM25 or the green fiber washer GFWM25 (washers to be ordered separately).| If the sealing surfaces are uneven, use PTFE washer NFWM25 or the green fiber washer GFWM25 (Washers to be ordered separately).
Maximum surface roughness of the enclosure wall| Ra 6,4µm, better than 3,2µm is recommended.| Ra 6,4µm, better than 3,2µm is recommended.
Thickness range for the enclosure wall (t)| ≥ 4 mm. For Ex db applications a minimum of 5 fully engaged threads is required. The thread will maintain an IP rating of IP64.
A sealing washer shall be used to maintain all IP ratings ≥ IP64.| Minimum wall thickness: Plastic boxes ≥ 2 mm
Metal boxes ≥ 1 mm but less than the thread length of the cable gland + the thickness of the locknut.
Perpendicularity| +/–1° or 0,2 mm at the outer edge of the gland, whichever is smaller.| +/–1° or 0,2 mm at the outer edge of the gland, whichever is smaller.
Permitted use and location of any earth tags| Earth tags should be installed on the inside of the enclosure. Thickness of tag and lock nut to be considered when determining the min/max wall thickness of the box.| Earth tags should be installed on the inside of the enclosure. Thickness of tag and lock nut to be considered when determining the min/max wall thickness of the box.
For chamfered holes| The outermost edge must not have a greater diameter than the center of the washer.| The outermost edge must not have a greater diameter than the center of the washer.
Lock nuts| Only use nVent RAYCHEM locknuts or other types recommended by the manufacturer.| Only use nVent RAYCHEM locknuts or other types recommended by the manufacturer.

  • Any thread sealant should be non-hardening.
  • It is the users/installers responsibility to ensure that the interface between the enclosure and cable gland is suitably sealed for the required application.
  • If required an anti-seize lubricant then ensure no lubricant comes into contact with the cable gland seals as this may impair performance.

Pass prepared heating cable end with core sealer through the box entry. Screw gland body into junction box. For C25-100-METAL, make sure the sealing ring is in place before doing so (use locknut for non-metallic boxes with internal earth plate).

nVent-RAYCHEM-C25-100-METAL-Metal-Connection-Kit-21

Position grommet in gland  body, ensuring it is seated squarely and tighten middle body securely.

Insert grommet for outer seal and tighten backnut. Connect conductors to the appropriate terminals.

Worldwide Headquarters
Tel 800-545-6258
Tel 650-216-1526
Fax 800-527-5703
Fax 650-474-7711
thermal.info@nVent.com

België / Belgique
Tel +32 16 21 35 02
Fax +32 16 21 36 04
salesbelux@nVent.com

Bulgaria
Tel +359 5686 6886
Fax +359 5686 6886
salesee@nVent.com

Česká Republika
Tel +420 602 232 969
czechinfo@nVent.com

Denmark
Tel +45 70 11 04 00
salesdk@nVent.com

Deutschland
Tel 0800 1818205
Fax 0800 1818204
salesde@nVent.com

España
Tel +34 911 59 30 60
Fax +34 900 98 32 64
ntm-sales-es@nVent.com

France
Tél 0800 906045
Fax 0800 906003
salesfr@nVent.com

Hrvatska
Tel +385 1 605 01 88
Fax +385 1 605 01 88
salesee@nVent.com

Italia
Tel +39 02 577 61 51
Fax +39 02 577 61 55 28
salesit@nVent.com

Lietuva/Latvija/Eesti
Tel +370 5 2136633
Fax +370 5 2330084
info.baltic@nVent.com

Magyarország
Tel +36 1 253 7617
Fax +36 1 253 7618
saleshu@nVent.com

Nederland
Tel 0800 0224978
Fax 0800 0224993
salesnl@nVent.com

Norge
Tel +47 66 81 79 90
salesno@nVent.com

Österreich
Tel 0800 29 74 10
Fax 0800 29 74 09
salesat@nVent.com

Polska
Tel +48 22 331 29 50
Fax +48 22 331 29 51
salespl@nVent.com

Republic of Kazakhstan
Tel +7 7122 32 09 68
Fax +7 7122 32 55 54
saleskz@nVent.com

Россия
Тел. +7 495 926 18 85
Факс +97 495 926 18 86
salesru@nVent.com

Serbia and Montenegro
Tel +381 230 401 770
Fax +381 230 401 770
salesee@nVent.com

Schweiz / Suisse
Tel +41 (41) 766 30 80
Fax +41 (41) 766 30 81
infoBaar@nVent.com

Suomi
Puh 0800 11 67 99
salesfi@nVent.com
Sverige
Tel +46 31 335 58 00
salesse@nVent.com

Türkiye
Tel +90 560 977 6467
Fax +32 16 21 36 04
salesee@nVent.com

United Kingdom
Tel 0800 969 013
Fax 0800 968 624
salesthermalUK@nVent.com

nVent.com/RAYCHEM

©2022 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice.
RAYCHEM-IM-INSTALL050-C25100METAL-ML-2209

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

nVent RAYCHEM User Manuals

Related Manuals