GREEN Tunnel Lamp Installation Guide

June 7, 2024
GREEN

Installation Manual Tunnel Lamp-T.60 Series (Non-dimmable)

Tunnel Lamp-T.60 Series

Product specification parameters

Product specification parameters

Product installation

Product Installation Figure 1

  1. Drill 4 holes on the mounting surface, it Is recommended to Install and fix them with M10 expansion screws. Different fixing methods are selected according to the installation position as shown below.
  2. After fixing the lamp, adjust the illuminating angle of the lamp, which should be slightly adjusted according to above figure
  3. Connecting power line: According to the different color of power cord, differentiate the Null wire/Live wire /Earth wire.

Attention: It is recommended that the professional electrician installs the lamp to avoid the danger of electric shock.

Male to Female Connection

When installing lamps, as shown in the figure above, the connection between male and female heads can only be inserted in the direction of arrows. Failure to operate in accordance with the regulations will cause damage to the lamps!

*Accessories are not standard equipped and need to purchase separately!

Product Installation Figure 2

Product Installation Figure 3

System connecting diagram

AC220V Definition of power cord|
---|---
Brown| L
Blue| N
Yellow/Green|

System connecting diagram

Attentions for system wire connection as below:

  1. The connection joint must be with well waterproof treatment, otherwise, if the water vapor enters into the lamp body due to there is no good waterproof treatment on the connection joint of the wire on the spot that cause the lamp damaged, the manufacturer will not bear any loss or responsibility caused thereby.

Don’t make any operation to the lamp without being cut off to avoid any personal injury or lamp damage!

Attention

  1. Installation environment: This lamp is suitable for outdoor lighting, environment temperature: -20°C ~40°C, IP 66, CLASS I.
  2. The working voltage or the driver information refer to the product specification or label.
  3. All wire layout inside must conform to national installation standards, all wiring joint must be connected well and waterproof treatment must be done as well.
  4. The lamp must be installed by professional personnel to avoid any danger occurred.
  5. Please don’t dismantle the lamp without authorization, otherwise our company will not bear any loss or responsibility thereby.
  6. Making sure the installation system must bear the weight of the lamp not less than 4 times.
    Any adjustment on the products by Changzhou Green Lighting Co., ltd, there is no further advice, please note.

Changzhou Green Lighting Co., Ltd.
No. 269 Fumin Rd, Economic Development Zone, Changzhou, China
Tel: 0519-88406000
Fax: 0519-88406100
Email: green@china-greenlighting.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GREEN User Manuals

Related Manuals