STEP ONE : Attach the second pumps to the tank.
SG52 FLOJET
PARTS LIST
ITEM| QTY| PART NUMBER| DESCRIPTION
1| 2| 60014-FJ| SPRAY PUMP, FLOJET
2| 1| W21-100| MOUNTING BRACKET, SPRAY PUMP
3| 2| S54120| HEAT SINK, SPRAY PUMP
4| 4| HFSSC-3812| HEX BOLT, 3/8 X 1/2
5| 8| HFSSC-141| BOLT, HEX, 1/4 X 1
6| 0| 20381713| PUMP FITTING, FLOJET, 1
7| 0| 20381712| PUMP FITTING, FLOJET, 3/4
SG46 FLOJET
PARTS LIST
ITEM| QTY| PART NUMBER| DESCRIPTION
1| 2| 60014-FJ| SPRAY PUMP, FLOJET
2| 2| 20381712| PUMP FITTING, FLOJET, 3/4
3| 2| 20381713| PUMP FITTING, FLOJET, 1
4| 2| S54120| HEAT SINK, SPRAY PUMP
5| 8| HFSSC-141| HEX FLANGE BOLT, 1/4 X 1
6| 1| W21-100| MOUNTING BRACKET, SPRAY PUMP
7| 4| HFSSC-3812| HEX FLANGE BOLT, 3/8 X 1/2
SG42 FLOJET
NOTE: Attach the second pump to the right side tank. Instructions are the same.
PARTS LIST
ITEM| QTY| PART NUMBER| DESCRIPTION
1| 2| 60014-FJ| SPRAY PUMP, FLOJET
2| 2| 20381712| PUMP FITTING, FLOJET, 3/4
3| 2| 20381713| PUMP FITTING, FLOJET, 1
4| 2| S54120| HEAT SINK, SPRAY PUMP
5| 2| W21-100| MOUNTING BRACKET, SPRAY PUMP
6| 8| HFSSC-141| HEX FLANGE BOLT, 1/4 X 1
7| 8| HFSSC-3812| HEX FLANGE BOLT, 3/8 X 1/2
SG36 FLOJET
NOTE: Attach the second pump to the right side tank. Instructions are
the same.
PARTS LIST
ITEM| QTY| PART NUMBER| DESCRIPTION
1| 2| 60014-FJ| SPRAY PUMP, FLOJET
2| 2| 20381712| PUMP FITTING, FLOJET, 3/4
3| 2| 20381713| PUMP FITTING, FLOJET, 1
4| 2| S54120| HEAT SINK, SPRAY PUMP
5| 2| W21-100| MOUNTING BRACKET, SPRAY PUMP
6| 8| HFSSC-141| HEX FLANGE BOLT, 1/4 X 1
7| 8| HFSSC-3812| HEX FLANGE BOLT, 3/8 X 1/2
STEP TWO:
- Assemble the (2) tee fitting assemblies as shown.
NOTE: Angle the elbow fittings as needed.
PARTS UST
ITEM| QTY| PART NUMBER| DESCRIPTION
1| 1| S52006| TEE, BANJIO, 3/4
2| 1| S52015| 3/4″ MNPT × 3/4″ BARB
3| 2| S52029| BARB, 3/4 MPT x 3/4 BARB 90
PARTS LIST
ITEM| QTY| PART NUMBER| DESCRIPTION
1| 1| S52017| 3/4 × 1 BARB
2| 2| S52030| 1 MNPT × 1 BARB, ELBOW, 90
3| 1| S52073| 1 FNPT, PIPE TEE
NOTE: ALL hoses are to be…..
- Securely fastened with hose clamps.
- Free of sharp edges and hot areas.
STEP THREE:
- Cut 3/4” return hose 16” long.
- Connect one end of the hose to the spray manifold inlet barb fitting
- Connect the 3/4” tee fitting assembly to the other end.
- Securely fasten with 12HS hose clamps.
STEP FOUR:
- Cut 3/4” return hose. (length as needed)
- Connect one end of the hose to the front elbow fitting and the other end to the “outlet port” of spray pump 1.
- Cut 3/4” return hose. (length as needed)
- Connect one end of the hose to the rear elbow fitting and connect the other end to the “outlet port” of spray pump 2.
- Cut 3/4” return hose. (length as needed)
- Connect one end of the hose to the rear elbow fitting and connect the other end to the “outlet port” of spray pump 2.
STEP FIVE:
- Cut (2) 1” suction hoses (length as needed).
- Connect one end of each hose to the 1” tee fitting assembly.
- Connect the other end of each 1” hose to the suction ports on the spray pumps.
STEP SIX:
- Cut 1” suction hose (length as needed).
- Connect the hose to the strainer “inlet port”.
- Connect the other end of the 1” hose to the bottom of the 1” tee fitting assembly.
DUAL PUMP HARNESS (SG-FT-DUAL)
CAUTION!
Before beginning any of the following instructions BESURE all the tanks have
been drained
NOTE:
- Disconnect the battery, ground first and then power wire.
- Before starting the following steps the existing pump wiring harness will need to be removed.
STEP SEVEN:
- Attach the harness relay ground wires to the nut on the suction\return valve assembly on the “right side”.
- Secure the relay end of the harness to the suction hose with zip ties.
STEP EIGHT: Route the wires for the foot switch down the upright with the existing bundle, through the hole in the foot board and connect them to the foot switch.
STEP TWELVE: Connect the pump power switch wires to the “rocker switch”
STEP NINE: Connect the wire for the key switch.
STEP TEN: Connect the “fused” connector to the positive terminal on the usb port.
STEP ELEVEN: Connect the #9 ground wires to the upright cross member.
STEP TWELVE: Connect the red power wires to the engine solenoid.
STEP THRITEEN:
- Connect both pump plugs to the harness .
- Zip tie the plugs to the suction hose as shown.
NOTE: Check the harness and make sure it is neatly routed and zip tied away from moving and hot parts..
STEP FOURTEEN:
- Reconnect the battery cables, power cable and wires first followed by the ground wire.
- Connect the power and ground cables from the harness.
- Attach the battery box cover and bungie strap.
NOTES —
Steel Green Mfg.
824 S State Road 39
Lebanon, IN 46052
(765)-481-2890
www.steelgreenmfg.com
MANUAL PART NO. | MANUAL REV. | DESCRIPTION | KIT PART NO. |
---|---|---|---|
SGM-015 | C | SG DOUBLE SPRAY PUMP | P60004 |
MADE IN THE USA
Documents / Resources
|
STEEL GREEN SG36 Double Spray
Pump
[pdf] Instruction Manual
SG36 Double Spray Pump, SG36, Double Spray Pump, Spray Pump, Pump
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>