ATEN RCMA200SA RCM Adapter Module with 60-pin and RS-232 Control for UF200SA Server User Manual

June 3, 2024
Aten

Adapter Module with 60-pin and RS-232 Control for UF200SA Server
User Manual

Haier AD140HP5FA-SET 14kW High Static Ducted -

Compliance Statements

FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide   easonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio  requency energy and, if not installed and  used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this  quipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.  The device  omplies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must  ccept any interference received, including interference that may cause undesired operation.

FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Warning
Operation of this equipment in a residential environment could cause radio interference.

Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
CANINES-003(A)NBM-003(A)
RoHS
This product is RoHS compliant.
User Information
Online Registration
Be sure to register your product at our online support center:
International : http://eservice.aten.com

Telephone Support

For telephone support, call this number:

International 886-2-8692-6959
China 86-400-810-0-810
Japan 81-3-5615-5811
Korea 82-2-467-6789
North America 1-888-999-ATEN ext 4988

User Notice
All information, documentation, and specifications contained in this manual are subject to change without prior notification by the manufacturer. The manufacturer makes no  epresentations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for  ny particular purpose. Any of the manufacturer’s software described in this manual is sold or licensed as is. Should the programs prove defective following their purchase, the  uyer (and  not the manufacturer, its distributor, or its dealer), assumes the entire cost of all necessary servicing, repair and any incidental or consequential damages resulting from any defect in the software.
The manufacturer of this system is not responsible for any radio and/or TV interference caused by unauthorized modifications to this device. It is the responsibility of the  ser to correct such interference. The manufacturer is not responsible for any damage incurred in the operation of this system if the correct operational voltage setting was not  elected prior to operation. PLEASE VERIFY THAT THE VOLTAGE SETTING IS CORRECT BEFORE USE.

Product Information

For information about all ATEN products and how they can help you connect without limits, visit ATEN on the Web or contact an ATEN Authorized Reseller. Visit ATEN  n the Web for a list of locations and telephone numbers:
International: http://www.aten.com
North America: http://www.aten-usa.com

Package Contents

Check to make sure that all the components are in working order. If you encounter any problem, please contact your dealer. 1 RCMA200SA RCM Adapter Module with 60- in and RS-232 Control for UF200SA Server
1 power adapter
1 console cable
1 foot pad set (4 pcs)
1 user instructions
About This Manual
This manual is provided to help you get the most out of your RCM Adapter Module with 60-pin and RS-232 Control for UF200SA Server. It covers all aspects of the device,  ncluding installation, configuration, and operation. An overview of the information found in the manual is provided below.
Chapter 1, Introduction, introduces you to the RCM Adapter Module with 60-pin and RS-232 Control for UF200SA Server, its purpose, features, and benefits, with its front and back panel components described.
Chapter 2, Hardware Setup, provides step-by-step instructions for setting up the RCM Adapter Module with 60-pin and RS-232  ontrol for UF200SA Server, and explains some of its basic operation procedures.
Appendix, provides the technical and troubleshooting information at the end of the manual.
Note:

  • Read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit or connected devices.
  • The product may be updated, with features and functions added, improved, or removed since the release of this manual. For an up-to-date user manual, visit http://www.aten.com/global/en/

Conventions
This manual uses the following conventions:
Monospaced Indicates text that you should key in.
[ ] Indicates keys you should press. For example, [Enter] means to press the Enter key. If keys need to be chorded, they appear together in the same bracket with a plus sign between them: [Ctrl+Alt].
1.Numbered lists represent procedures with sequential steps.
♦ Bullet lists provide information, but do not involve sequential steps.

Indicates selecting consecutive options (such as on a menu or dialog box). For example, Start > Run means to open the Start menu, and then select Run.
**** Indicates critical information

Chapter 1 Introduction

Overview
The RCMA200SA, the industry’s first adapter module, is designed to work with ATEN KA7174 and RCM series multi-port products (such as RCM816), it can easily access  F300 and UF200SA from both local and remote consoles.  It also supports virtual keyboard for the convenience of installation and application.
Features

  • Designed for UF300 and UF200SA production line application
  • With ATEN KA7174 and RCM series multi-port products (such as RCM816), the RCMA200SA can easily access from local console and over IP remote console.
  • Supports virtual keyboard for easy operation
  • Firmware upgradable

Requirements
Console

  •  An UF300 or UF200SA touch panel
  • An UF300 or UF200SA keyboard
  •  A KA7174 and RCM series multi-port products (such as RCM816)

Components
Front View

Haier AD140HP5FA-SET 14kW High Static Ducted - Fig

Rear View

Haier AD140HP5FA-SET 14kW High Static Ducted - Fig1

No. Component Description
1 60-pin output port Connects to an UF300 or UF200SA work station via the

supplied console cable.
2| power LED| Lights green: The unit is receiving power.
Off: The unit is powered off.
3| RS-232 serial port| This RS-232 serial port is for connecting to a serial terminal port on a KA7174. This serial port is designed to work with KA7174 only.
4| 60-pin input port| Connects to an UF300 or UF200SA touch panel and an UF300 or UF200SA keyboard via the supplied console cable.
5| power jack| Receives a power adapter to supply power to the unit.

Chapter 2 Hardware Setup

Overview
This chapter outlines a quick hardware connection summary for single station installation.
Before You Begin

  1. Important safety information regarding the placement and grounding of this device is provided on page 7 and onwards. Please review it before proceeding.
  2. Make sure that power to all the devices you will be connecting up have been turned off. You must unplug the power cords of any computers that have the Keyboard Power On function.
  3. **** Please operate the device with caution when under high environmental temperatures, as the surface of the device may become overheated under such conditions. For instance, the surface temperature of the device may reach 70 °C (158 °F) or higher when the environmental temperature reaches close 50 °C (122 °F).

Single Station Installation

For single station installation, refer to the installation diagram and procedures below. The numbers shown in the diagram correspond to the installation procedure step numbers.

  1. Connect your UF300 or UF200SA touch panel and an UF300 or UF200SA keyboard to the unit’s 60-pin input port using the supplied console cable.
  2. For control of serial devices, connect a serial port on a KA7174 to theunit’s RS-232 serial port. This RS-232 serial port is designed to work witKA7174 only.
  3.  Connect the UF300 or UF200SA work station to the unit’s 60-pin output using the supplied console cable.
  4. Connect the unit to power, thereby turning it on, by plugging the power adapter into AC power source and plug the other ends into the unit’s power jack. Please see Powering On Sequence, page 5 before powering on the RCMA200SA.

Haier AD140HP5FA-SET 14kW High Static Ducted - Fig2

Powering On Sequence
Please follow the power sequence below to safely power on the RCMA200SA.

  1. Make sure the UF300 and UF200SA is turned off.
  2. Connect all the cables and devices required for your installation. See Single Station Installation, page 4.
  3. Power on KA7174 and RCM series multi-port devices and then power on the RCMA200SA.

Note: The RCMA200SA does not support hot plugging.
Powering Off and Restarting
If it becomes necessary to power off the console station, disconnect the power adapter and wait for 30 seconds before reconnecting it back.

Appendix

Safety Instructions
General

  • This product is for indoor use only.
  • Read all of these instructions. Save them for future reference.
  • Follow all warnings and instructions marked on the device.
  • Do not place the device on any unstable surface (cart, stand, table, etc.). If the device falls, serious damage will result.
  • Do not use the device near water.
  • Do not place the device near, or over, radiators or heat registers.
  • The device cabinet is provided with slots and openings to allow for adequate ventilation. To ensure reliable operation, and to protect against overheating, these openings must never be blocked or covered.
  • The device should never be placed on a soft surface (bed, sofa, rug, etc.) as this will block its ventilation openings. Likewise, the device should not be placed in a built in enclosure unless adequate ventilation has been provided.
  • Never spill liquid of any kind on the device.
  • Avoid circuit overloads. Before connecting equipment to a circuit, know the power supply’s limit and never exceed it. Always review the electrical specifications of a circuit to ensure that you are not creating a dangerous condition or that one doesn’t already exist. Circuit overloads can cause a fire and destroy equipment.
  • Unplug the device from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.
  • The device should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
  • To prevent damage to your installation it is important that all devices are properly grounded.
  • Do not allow anything to rest on the power cord or cables. Route the power cord and cables so that they cannot be stepped on or tripped over.
  • Position system cables and power cables carefully; Be sure that nothing rests on any cables.
  • When connecting or disconnecting power to hot-pluggable power supplies, observe the following guidelines:
  • Install the power supply before connecting the power cable to the power supply.
  • Unplug the power cable before removing the power supply.
  • If the system has multiple sources of power, disconnect power from the system by unplugging all power cables from the power supplies.
  • Never push objects of any kind into or through cabinet slots. They may touch dangerous voltage points or short out parts resulting in a risk of fire or electrical shock.
  • Do not attempt to service the device yourself. Refer all servicing to qualified service personnel.
  • If the following conditions occur, unplug the device from the wall outlet and bring it to qualified service personnel for repair.
  • The power cord or plug has become damaged or frayed.
  • Liquid has been spilled into the device.
  • The device has been exposed to rain or water.
  • The device has been dropped, or the cabinet has been damaged.
  • The device exhibits a distinct change in performance, indicating a need for service.
  • The device does not operate normally when the operating instructions are followed.
  • Only adjust those controls that are covered in the operating instructions. Improper adjustment of other controls may result in damage that will require extensive work by a qualified technician to repair.
  • Additional protection to secure and fix the equipment is needed if the equipment is installed by stacking; by locking it to the rack, screwing it to the frame, or other similar methods.
  • Keep the Cat 5e/6 cable as far away as possible from potential sources of EMI, such as electrical cables, transformers, and light fixtures. Do not tie the cables to electrical conduits or lay the cables on electrical fixtures.

Rack Mounting

  • Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack.
  • Always load the rack from the bottom up, and load the heaviest item in the rack first.
  • Make sure that the rack is level and stable before extending a device from the rack.
  • Use caution when pressing the device rail release latches and sliding a device into or out of a rack; the slide rails can pinch your fingers.
  • After a device is inserted into the rack, carefully extend the rail into a locking position, and then slide the device into the rack.
  • Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not exceed 80 percent of the branch circuit rating.
  • Make sure that all equipment used on the rack – including power strips and other electrical connectors – is properly grounded.
  • Ensure that proper airflow is provided to devices in the rack.
  • Ensure that the operating ambient temperature of the rack environment does not exceed the maximum ambient temperature specified for the equipment by the manufacturer
  • Do not step on or stand on any device when servicing other devices in a rack.

Technical Support

International

  • For online technical support – including troubleshooting, documentation, and software updates: http://eservice.aten.com
  • For telephone support, see Telephone Support on page iv

North America

Email Support support@aten-usa.com
Online Technical Support Troubleshooting Documentation Software Updates

http://eservice.aten.com
Telephone Support| 1-888-999-ATEN ext 4988
1-949-428-1111

When you contact us, please have the following information ready beforehand:

  • Product model number, serial number, and date of purchase.
  • Your computer configuration, including operating system, revision level, expansion cards, and software.
  •  Any error messages displayed at the time the error occurred.
  • The sequence of operations that led up to the error.
  •  Any other information you feel may be of help.

Specifications

Function RCMA200SA

Connectors
Console Ports| 1 x Custom 60-pin Connector (Black)
(VM Ports| 1 x Custom 60-pin Connector (Black)
Dower| 1 x DC Jack (Black)
RS -232| 1 x DB-9 Male (Black)
EDs
;Dwer| 1 (Green)
Dower Consumption| DC5V:0.38W:2BTU
Environmental
Operating Temperature| 0 – 50 °C
Storage Temperature| -20 – 60 °C
Humidity| 0 – 80% RH. Non-condensing
Physical Properties
Housing| Metal
Weight| 0.31 kg (0.62 lb)
Dimensions (L x W x H)| 12.80 x 8.16 x 2.50 cm (5.04 x 3.21 x 0.98 in)

Limited Warranty

ATEN warrants its hardware in the country of purchase against flaws in materials and workmanship for a Warranty Period of two [2] years (warranty period may vary in   ertain regions/countries) commencing on the date of original purchase. This warranty period includes the LCD panel of ATEN LCD KVM switches. Select products are  arranted for an additional year (see A+ Warranty for further details). Cables and accessories are not covered by the Standard Warranty.
What is covered by the Limited Hardware Warranty
ATEN will provide a repair service, without charge, during the Warranty Period. If a product is detective, ATEN will, at its discretion, have the option to (1) repair said  roduct with new or repaired components, or (2) replace the entire product with an identical product or with a similar product which fulfills the same function as the defective  roduct. Replaced products assume the warranty of the original product for the remaining period or a period of 90 days, whichever is longer. When the products or  omponents are replaced, the replacing articles shall become customer property and the replaced articles shall become the property of ATEN.
To learn more about our warranty policies, please visit our website: http://www.aten.com/global/en/legal/policies/warranty-policy/

© Copyright 2022 ATEN® International Co., Ltd.
Released: 2022-10-27
ATEN and the ATEN logo are registered trademarks of ATEN International Co., Ltd. All rights reserved.
All other brand names and trademarks are the registered property of their respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals