**POLAR Stainless Steel Counter Refrigerators Freezers Instruction Manual

**

Safety Tips

  • Position on a flat, stable surface.
  • A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
  • Consult Local and National Standards to comply with the following: – Health and Safety at Work Legislation – Fire Precautions – Wiring Regulations – Building Regulations
  • DO NOT use jet/pressure washers to clean the appliance.
  • DO NOT use the appliance outside.
  • DO NOT use this appliance to store medical supplies.
  • DO NOT stand or support yourself on the base, drawers or doors.
  • DO NOT allow oil or fat to come into contact with the plastic components or door seal. Clean immediately if contact occurs.
  • Bottles that contain a high percentage of alcohol must be sealed and placed vertically in the refrigerator.
  • Always carry, store and handle the appliance in a vertical position and move by holding the base of the appliance.
  • Always switch off and disconnect the power supply to the unit before cleaning.
  • Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • If the power cord is damaged, it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard.
  • POLAR recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing.

Caution Risk of Fire

  • Do not store explosive substances such as aerosol cans with a
    flammable propellant in this appliance.

Warning : Keep all ventilation openings clear of obstruction. Unit should not be boxed in without adequate ventilation.

  • Warning : Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • Warning: Do not damage the refrigerant circuit.
  • Warning: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are the type recommended by the manufacturer.

Product Description

G596-A POLAR 282 litre 2 Door Counter Refrigerator
G597-A POLAR 417 litre 3 Door Counter Refrigerator
G598-A POLAR 553 litre 4 Door Counter Refrigerator
G599-A POLAR 282 litre 2 Door Counter Freezer
G600-A  POLAR 417 litre 3 Door Counter Freezer
DL914-A  Polar Counter GN REFRIGERATOR – 2 Doors 700mm with upstand
DL915-A Polar Counter GN REFRIGERATOR – 3 Doors 700mm with upstand
DL916-A Polar Counter GN FREEZER – 2 Doors 700mm with upstand
DL917-A Polar Counter GN FREEZER – 3 Doors 700mm with upstand
G377-A  POLAR 2 Door Counter Refrigerator
G378-A  POLAR 3 Door Counter Refrigerator
G379-A  POLAR 4 Door Counter Refrigerator

Introduction

Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.

Pack Contents

The following is included:

  • POLAR Refrigerator or Freezer
  • Shelf guide (2 per door)
  • Shelf (1 per door)
  • Instruction manual
  • Spacer (x2)

POLAR prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage. Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation

Note : If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.

  1. Remove the appliance from the packaging. Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces

  2. To optimize performance and longevity, ensure a minimum clearance of 2.5cm is maintained between the unit and walls and other objects, with a minimum 5cm clearance on the top. NEVER LOCATE NEXT TO A HEAT SOURCE.
    Note:
    To avoid being pushed tight against the wall accidentally and ensure good ventilation, 2 spaces are supplied for mounting on the rear.

  3. Set the brakes on the castors to keep the appliance in position.

Note: Before using the appliance for the first time, clean the shelves and interior with soapy water

Fitting the Shelves & Floor Guards

  1. Place one set of shelf guides on either side of the cabinet at the desired height.
  2. Slide the shelf into place.
  3. Repeat for the remaining shelves.
  4. Place the floor guards on the floor of the cabinet, ensuring the flat side is clear of the floor

Note : This is vital for ensuring correct drainage of condensation.

Operation

Storing Food:
To get the best results from your POLAR appliance, follow these instructions:

  • Only store foodstuffs in the appliance when it has reached the correct operating temperature.

  • Do not place uncovered hot food or liquid inside the appliance.
    • Wrap or cover food where possible.

  • Do not obstruct the fans inside the appliance.

  • Avoid opening the doors for prolonged periods of time.

Turn On:

  1. Ensure the power switch is set to [ O ] and turn on at the socket.
  2. Switch on the Power [I]. The current temperature within the appliance is displayed.

Control Panel:
Control Panel

Set the Operating Temperature:

  1. Hold the SET button for 3 seconds. The value of the current set point will be displayed.
  2.  Press the or  buttons to display the required temperature.
  3. Press the SET button to store the temperature.

Manual Defrost:

  • The appliance will automatically run a defrost cycle every six hours.
  • To manually defrost the appliance: Press and hold the defrost button “aux” for 2 seconds to begin a manual defrost. The defrost light illuminates.

Cleaning, Care & Maintenance

Defrost appliance at least every 3 months, more often if required. Switch off and disconnect from the power supply before cleaning.

  • Clean the interior of the appliance as often as possible.
  • Do not use abrasive cleaning agents. These can leave harmful residues.
  • Clean the door seal with warm soapy water.
  • Always wipe dry after cleaning.
  • Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
  • Take care when cleaning the rear of the appliance. Sharp edges can cut.
  • A POLAR agent or qualified technician must carry out repairs if required.

Stainless Steel Care:
To maintain the stainless steel exterior of your Polar item, please consider the following information:

Never

  • Use abrasive Scourers or scrubbing pads, etc.
  • Use Chlorinated or acidic detergents
  • Allow anything e.g. food, dirt, cleaning chemicals to remain on the surface for longer than necessary, clean them off right away.
  • Allow the surface to remain wet.

Do

  • Clean often.
  • Use soft Cloths or plastic Scourers.
  • Rub with the grain of the metal, rather than across it. Use detergents and
  • polish designed for cleaning Stainless Steel.
  • Ensure that the cleaning products are washed off fully and that the steel is left dry.

Routine Maintenance

Condenser Cleaning:

  • The condenser is part of the refrigeration system. The condenser requires monthly cleaning.
  • Always disconnect power supply before carrying out Routine Maintenance.
  • Failure to clean the condenser will reduce the performance and life of your Polar unit and may invalidate your warranty
  • The condenser is located behind the service door on the right-hand side of the refrigeration cabinet.
  • These models have a removable filter which can be cleaned with a vacuum cleaner.
    Routine Maintenance

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer

Fault Probable Cause Solution
The appliance is not working The unit is not switched on Check the unit is

plugged in correctly and switched on
Plug or lead is damaged| Call POLAR agent or qualified Technician
Power supply| Check power supply
The appliance turns on, but the temperature is too high/low| Too much ice on the evaporator| Defrost the appliance
Condenser blocked with dust| Clean the Condenser
Doors are not shut properly| Check doors are shut and seals are not damaged
Appliance is located near a heat source or air flow to the condenser is being interrupted| Move the refrigerator to a more suitable location
Ambient temperature is too high| Increase ventilation or move appliance to a cooler position
Unsuitable foodstuffs are being stored in the appliance| Remove any excessive hot foodstuffs or blockages to the fan
Appliance is overloaded| Reduce the amount of food stored in the appliance
The appliance is leaking water| The appliance is not properly levelled| Adjust the screw feet to level the appliance (if applicable)
The discharge outlet is blocked| Clear the discharge outlet
Movement of water to the drain is obstructed| Clear the floor of the appliance (if applicable)
The water container is damaged| Call POLAR agent or qualified Technician
The drip tray is overflowing| Empty the drip tray (if applicable)
The appliance is unusually loud| Loose nut/screw| Check and tighten all nuts and screws
The appliance has not been installed in a level or stable position| Check installation position and change if necessary

Telephone Helpline: 1300225960

Technical Specifications


Model

| ****

Voltage

| ****

Power

| ****

Current

| ****

Temperature Range

| Net Capacity (Litre)
---|---|---|---|---|---
G596-A| 220-240V~ 50Hz| 350W| 1.95A| -2°C to 8°C| 205
G597-A| 220-240V~ 50Hz| 350W| 1.95A| -2°C to 8°C| 358
G598-A| 220-240V~ 50Hz| 350W| 1.95A| -2°C to 8°C| 476
G599-A| 220-240V~ 50Hz| 750W| 3.5A| -10°C to -20°C| 205
G600-A| 220-240V~ 50Hz| 750W| 3.55A| -10°C to -20°C| 358
DL914-A| 220-240V~ 50Hz| 350W| 1.95A| -2°C to 8°C| 205
DL915-A| 220-240V~ 50Hz| 350W| 1.95A| -2°C to 8°C| 358
DL916-A| 220-240V~ 50Hz| 750W| 3.5A| -10°C to -20°C| 205
DL917-A| 220-240V~ 50Hz| 750W| 3.5A| -10°C to -20°C| 358
G377-A| 220-240V~ 50Hz| 300W| 1.8A| -2°C to 8°C| 166
G378-A| 220-240V~ 50Hz| 300W| 1.8A| -2°C to 8°C| 310
G379-A| 220-240V~ 50Hz| 300W| 1.8A| -2°C to 8°C| 398
Model| Refrigerant| Dimensions H x W x D mm| Weight (kg)
---|---|---|---
G596-A| R290 95g| 860 x 1360 x 700| 98
G597-A| R290 95g| 860 x 1795 x 700| 134
G598-A| R290 95g| 860 x 2230 x 700| 153
G599-A| R290 90g| 860 x 1360 x 700| 98
G600-A| R290 90g| 860 x 1795 x 700| 136
DL914-A| R600a 95g| 960 x 1360 x 700| 108
DL915-A| R600a 95g| 960 x 1795 x 700| 139
DL916-A| R290 90g| 960 x 1360 x 700| 108
DL917-A| R290 90g| 960 x 1795 x 700| 143
G377-A| R600a 80g| 860 x 1360 x 600| 88
G378-A| R600a 80g| 860 x 1795 x 600| 125
G379-A| R600a 80g| 860 x 2230 x 600| 143

Electrical Wiring

The plug is to be connected to a suitable mains socket.

This appliance is wired as follows:

  • Live wire (coloured brown) to terminal marked L
  • Neutral wire (coloured blue) to terminal marked N
  •  Earth wire (coloured green/yellow) to terminal marked E

Electrical Wiring The appliances must be earthed.

If in doubt consult a qualified electrician.

Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Compliance

The product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
Compliance icon

POLAR products have been approved to carry the following symbol:

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR. Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without notice.

DECLARATION OF CONFORMITY

Equipment Type

| Model
---|---
Counter refrigerator:| | | Counter refrigerator:
1.    2 door 600 mm| 8.| 2 door 2 drawers| 1.    G377 (-E & -A)            8. GD874 (-E & -A)
2.    3 door 600 mm| 9.| 2 door Gastro with upstand| 2.    G378 (-E & -A) 9.    DL914 (-E & -A)
3.    4 door 600 mm| 10.| 3 door Gastro with upstand| 3.    G379 (-E & -A) 10.       DL915 (-E & -A)
4.    2 door Gastro| 11.| 3 door marble top bakery| 4.    G596 (-E & -A) 11.       GL182 (-E & -A)
5.    3 door Gastro| 12.| 2 door Euronorm| 5.    G597 (-E & -A)            12. GL183 (-E & -A)
6.    4 door Gastro| 13.| 3 Door Euronorm| 6.    G598 (-E & -A)            13. GL184 (-E & -A)
7.    1 door 2 drawers| | | 7.    GD873 (-E & -A)
Counter Freezer :| | | Counter Freezer:
1.    2 door Gastro| 3.| 2 door Gastro with upstand| 1.    G599 (-E & -A) 3.    DL916 (-E & -A)
2.    3 door gastro| 4.| 3 door Gastro with upstand| 2.    G600 (-E & -A) 4.    DL917 (-E & -A)
Application of Territory Legislation &| Machinery Directive 2006/42/EC| Electrical Safety
Council Directives(s)| EN 60335-1:2012 +A11:2014 +A13:2017| IEC 60335-1:2010 +A1:2013 +A13:2017
| EN 60335-2-89:2010 +A1:2016 +A2:2017| IEC 60335-2-89:2010 +A1:2012 +A2:2015
| EN 62233:2008|
| |
| Electro-Magnetic Compatibility (EMC) Directive| Electromagnetic Compatibility
**| 2014/30/EU – recast of 2004/108/EC| EN 55014-1: 2017
**
| EN 55014-1: 2017| EN 55014-2: 2015
| EN 55014-2: 2015| EN 61000-3-2: 2014
| EN 61000-3-2: 2014| EN 61000-3-3: 2013
| EN 61000-3-3: 2013|
| Restriction of Hazardous Substances Directive|
| (RoHS) 2015/863 amending Annex II to Directive|
| 2011/65/EU|
Producer Name| Polar

The undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and Standard(s)

Date 18th November 2020
Signature ![Signature](https://manuals.plus/wp-
content/uploads/2021/08/Screenshot_1-36-300x75.png)

Signature|
Full Name| Ashley Hooper| Eoghan Donnellan| Josie Holt
Position| Technical & Quality Manage| Commercial Manager/ Importer| Commercial Manager/ Responsible Supplier
Producer Address| Fourth Way, Avonmouth, Bristol, BS11 8TB United Kingdom| 42 North Point Business Park New Mallow Road Cork Ireland| 15 Bagdally Road, Campbelltown NSW 2560

QR Code
http://www.polar-refrigerator.com/

POLAR Stainless Steel Counter Refrigerators Freezers Instruction
Manual

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Polar User Manuals

Related Manuals