EarthTronics AL150WSCCTBK5 LED Area Light Instructions

June 12, 2024
EarthTronics

EarthTronics AL150WSCCTBK5 LED Area Light Instructions
EarthTronics AL150WSCCTBK5 LED Area Light

Cautions

  1. DO NOT use an electric generator to test this LED fixture.
  2. Please abide by any related country, regional and local laws and regulations when installing this fixture.
  3. To avoid any electrical shock or damage, please do not install on rainy days.

Notices

  1. To prevent the risk of fire or electric shock, the installation must be conducted by operator who has professional electrical knowledge.
  2. Please wear gloves to avoid injury before installing lamps.
  3. During or after installation, if there are situations such as smoke, fire in the fixture, please turn off the power immediately.
  4. This light can be used for outdoor installation.

Parameters

Part No.| Input Voltage| Frequency| Power| Rated Current
---|---|---|---|---
AL150WSCCTBK5| AC120-347V| 50/60Hz| 70W/100W/150W Selectabl| 1.375A
AL300WSCCTBK5| 200W/240W/300W Selectable| 2.75A

CCT or Watts selected Operation Manual

Fixture Power (W) and/or Color Temperature (CCT) from factory settings are:
AL150WSCCTBK5 150W/50K
AL300WSCCTBK5 300W/50K

  1. Take off the waterproof cover

  2. Select the Wattage or CCT by using the slide switch.
    Operation Manual

  3. Put back the waterproof cover or screw the sensor and the rubber pad.

Wiring Diagram

Wiring Diagram

Optional Brackets and Installation Instructions

There are 4 optional brackets for this fixture.
The following are shoebox fixtures with different brackets.
Optional Brackets and Installation Instructions

11767 Slip Filter

Step 1: Disassemble the slip-fitter with a wrench

Step 2: Pass the fixture’s AC input wires through the fixing base, then tighten screws to assemble fixing base to fixture body.
Slip Filter

Step 3: Pass the fixture’s input wires through the lamp holder and lock it.
Slip Filter

Step 4: Loosen the 4 locking bolts in the Type A bracket by a wrench.
Slip Filter

Step 5: Connect the fixture’s AC input wires to pole-wires with connectors, L to L (black), N to N (White), PE to PE (Green); If need to connect dimming wires from the pole to fixture, please also use the connector to connect “Dim +”(purple) to “Dim +”(purple), “Dim – “(pink) to “Dim-“(pink).
Slip Filter

Step 6: Tighten the 4 locking bolts back.

Step 7 : Loosen the locking bolt in the slip-fitter by a wrench to adjust fixture to a appropriate angle,adjustable angle range 90 then this locking bolt

11768-(Square/Round pole-mount with slip-fitter function)

Step 1: Disassemble the bracket with a wrench, open the cover on the lamp holder.
slip-fitter function

Step 2: Pass fixture’s AC input wires through fixing base, tighten screws to assemble fixing base to fixture body.
slip-fitter function

Step 3: Pass the fixture’s input wires through the lamp holder and lock it
slip-fitter function

Step 4: Remove the screws with screwdriver, well set the installed iron bar, remove the screws to open the junction box cover, then pass fixture’s AC input wires through junction box as shown in step 3.
slip-fitter function

Step 5: When install to square/round pole, align the holes of Type B bracket and pole, pass the fixing screws throughout both holes, then put iron bard inside of pole to attach screws.
slip-fitter function

Attention: When install round pole, please remove the rubber gasket.

Step 6:

  1. Pass the fixture’s AC input wires through pole, pull them out together the pole-wires for connection,
  2. Pass the pole-wires into Type B bracket, pull them out together with fixture’s AC wire from junction box, connect the fixtre’s AC input wires to pole-wires with connectors, L to L (black), N to N (White), PE to PE (Green); If need to connect dimming wires from the pole to fixture, pleas also use the connector to connect “Dim +”(purple) to “Dim +”(purple), “Dim – “(pink) to “Dim -“(pink).
    slip-fitter function

Step 7:

  1. Push the connected wires into the pole, close the pole’s top cover,the close the junction box cover by tightening the screws.
    slip-fitter function

  2. Push the connected wires into bracket junction box, close the box cover by tightening the screws, then close the pole’s top cover
    slip-fitter function

Step 8: Loosen the locking bolt by a wrench to adjust the fixture to a appropriate angle,adjustment range 15°,then tighten this locking
slip-fitter function

11760-Trunnion

Step 1 : Mark the fixing holes locations on the wall with Type D bracket, then drill the hole in 10mm diameter with an electric drill;
Trunnion

Step 2 : Knock the two expansion bolts into wall with a hammer
Trunnion

Step 3: Fix the TYPE D bracket on the mounting-surface by tightening screws with a wrench.
Trunnion

Step 4: Pass the fixture’s AC input wires through the Type D bracket; then hang the fixture into the TYPE D bracket, tighten screws to lock it to Type D bracket with a wrench.
Trunnion

Step 5: Loosen the angle adjustable screws on both sides of Type D bracket, rotate fixture to an appropriate angle required and tighten the two screws, see fig.31; then connect the fixture’s Note: The adjustable angel range is 0-90 °
Trunnion

11770 & 11771 – (Yoke) Installation

Step 1. Loosen the screws on both sides of the bracket with a wrench, adjust TYPE E bracket’s angle to keep parallel with its installation surface.
Installation

Step 2: Mark the installing hole locations on the wall with Type E bracket, then drill the holes in 10mm diameter with an electric drill.
Installation

Step 3: Knock the one expansion bolt into each wal-hole with a hammer.
Installation

Step 4: Put Type E bracket to expansion screw for wall-installing by tightening the nut with a wrench, connect fixture’s AC input wire to L N PE, then make waterproof processing to joints, put wires back into junction box.
Installation

Note: The adjustable angel range is 0-90°.

EarthTronics logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals