POLAR CD229-A Refrigerated Display Merchandiser Instruction Manual

October 30, 2023
Polar

Refrigerated
Merchandiser
Instruction manual

POLAR CD229-A Refrigerated Display Merchandiser Model:
CD229-A / CD230-A

Safety Instructions

Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.

  • Position on a flat, stable surface.

  • A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
    – In Queensland the service agent/qualified technician MUST hold a Gas Work Authorization or License for hydrocarbon refrigerants if the appliance gas system is being opened or charged.

  • Consult Local and National Standards to comply with the following:
    – Health and Safety at Work Legislation
    – Fire Precautions
    – Wiring Regulations
    – Building Regulations

  • DO NOT use jet/pressure washers to clean the appliance.

  • DO NOT use the appliance outside.

  • DO NOT use this appliance to store medical supplies.

  • DO NOT allow oil or fat to come into contact with the plastic components or door seal. Clean immediately if contact occurs.

  • DO NOT store products on top of the appliance.

  • Bottles that contain a high percentage of alcohol must be sealed and placed vertically in the refrigerator.

  • Always carry, store and handle the appliance in a vertical position and move by holding the base of the appliance.

  • Always switch off and disconnect the power supply to the unit before cleaning.

  • Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.

  • Children should be supervised to ensure that they do not play with the appliance.

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

  • Polar recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing.

Caution: Risk of Fire

  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.

Warning: Keep all ventilation openings clear of obstruction. Unit should not be boxed in without adequate ventilation.

  • To comply with AS/NZS 60079.10.1:2009: Ensure there are not sources of ignition in any area where refrigerant could gather in the event of a leak.
  • Electrical equipment should not be placed under the vent or where refrigerant could gather in the event of a leak.
  • Warning: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • Warning: Do not damage the refrigerant circuit.
  • Warning: Do not use electrical appliances inside the food storage compartments of the appliance.

Product Description

CD229-A – POLAR Refrigerated Display Merchandiser 120 litr
CD230-A – POLAR Refrigerated Display Merchandiser 160 litr

Pack Contents

The following is included:

  • POLAR Counter-Top Refrigerated Merchandiser
  • Shelves x 2
  • Instruction manual

POLAR prides itself on quality and service, ensuring that at the time of unpacking the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation

Note: Not for use in vans or trailers, food trucks or similar vehicles.
If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.

  • Remove the appliance from the packaging. Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces.
  • To optimize performance and longevity, ensure a minimum clearance of 2.5cm is maintained between the unit and walls and other objects, with a minimum 20cm clearance on the top. NEVER LOCATE NEXT TO A HEAT SOURCE.

Note: Before using the appliance for the first time, clean the shelves and interior with soapy water then dry well.

Operation

Control Panel
The control panel is located below the doors on therein of the appliance.

POLAR CD229-A Refrigerated Display Merchandiser - Control
Panel

Turn On

  1. Close the doors of the appliance.
  2. Connect the appliance to a mains power supply.
  3. Press the button to turn the light On or Off as required.

Setting the Operating Temperature

  1. Press the SET button. The display will flash.
  2. Press the  buttons to display the required temperature.
  3. Press the SET button to store the temperature.

Manual Defrost
Press and hold the button for 6 seconds to begin automatic defrost. The defrost light illuminates.

Cleaning, Care & Maintenance

  1. Switch off and disconnect from the power supply before cleaning.
  2. The doors can be removed for ease of cleaning.
  3. Clean the interior of the appliance as often as possible.
  4.  Do not use abrasive cleaning agents. These can leave harmful residues.
  5. Clean the door seal with warm soapy water.
  6. Always wipe dry after cleaning.

Condensation and ice will form with frequent and prolonged opening of the doors. Operating outside of the recommend temperature range and placing next to a heat source will also increase the amount of ice and internal/external condensation. If external condensation occurs wipe the surface down with a cloth. Excessive ice will result in longer running times that will increase energy consumption and increase the deterioration of components.
Replacing the Interior Lamp
Call your POLAR dealer or a qualified electrician, the Lamp Assembly is available to purchase as a spare part.
Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance.
POLAR recommend that a POLAR agent or qualified technician clean the condenser.

Troubleshooting

A qualified technician must carry out repairs if required.

Fault Probable Cause Solution
The appliance is not working The unit is not switched on Check the unit is

plugged in correctly and switched on
Plug or lead is damaged| Replace plug or lead
Mains power supply fault| Check mains power supply
The appliance turns on, but the temperature is too high/ low| Too much ice on the condenser| Defrost the appliance
Condenser blocked with dust| Clean the condenser
Doors are not shut properly| Check doors are shut and seals are not damaged
Appliance is located near a heat source, in the direct sunlight or air flow to the condenser is being interrupted| Move the refrigerator to a more suitable location
Ambient temperature is too high| Increase ventilation or move appliance to a cooler position
Unsuitable foodstuffs are being stored in the appliance| Remove any excessive hot foodstuffs or blockages to fan
Appliance is overloaded| Reduce the amount of food stored in the appliance
The appliance is leaking water| The appliance is not properly levelled| Adjust the screw feet to level the appliance (if applicable)
The appliance is unusually loud| Loose screw/nut| Check and tighten all nuts and screws
The appliance has not been installed in a level or stable position| Check installation position and change if necessary
The display lamp does not illuminate| Lamp needs replacing| Replace the lamp
 Light not turned on| Ensure Light button has been pressed properly
Door does not shut| Dirt/obstacle in runners| Clean runners
Error code EE4| • Restricted Airflow
• Blocked Condenser| • Increase airflow
• Clean the condenser

Technical Specifications

Note: Due to our continuing program of research and development, the specifications herein may be subject to change without notice.

Model| Voltage| Power (W)| Current (A)| Temperature Range| Capacity (Ltr)| Refrigerant| Dimensions H x W x D mm| Weight (kg)
---|---|---|---|---|---|---|---|---
CD229-A| 220-240V-
50Hz| 160| 1.4A| 2°C to 12°C| 120| R600a (50g)| 686 x 696 x 568| 57
CD230-A| 200| 1.4A| 2°C to 12°C| 160| R600a (65g)| 686 x 874 x 568| 66

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:

  • Live wire (cultured brown) to terminal marked L
  • Neutral wire (cultured blue) to terminal marked N
  • Earth wire (cultured green/yellow) to terminal marked E

**** This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Compliance

The product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
** POLAR products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without notice.
DECLARATION OF CONFORMITY**

Equipment Type Model

Countertop Refrigerated Merchandiser (Digital Controller) Black
Countertop Refrigerated Merchandiser (Digital Controller) White
Refrigerated Display Merchandiser – 120Ltr
Refrigerated Display Merchandiser – 160Ltr| CC611 (& -E -A)
CC666 (& -E -A)
CD229 (& -E -A)
CD230 (& -E -A)
Application of Territory Legislation & Council Directives(s)| Low Voltage Directive (LVD) – 2014/35/EU (BS) EN 60335-1:2012 +A11:2014 +A13:2017 +A1:2019 +A14:2019 +A2:2019
(BS) EN 60335-2-89:2010 +A1:2016 +A2:2017 (BS) EN 62233:2008
Electro-Magnetic Compatibility (EMC)
Directive 2014/30/EU – recast of 2004/108/EC (BS) EN IEC 61000-6-1: 2019
(BS) EN IEC 61000-6-3: 2021
Eco-design energy-related products Directive 2009/125/EC; Regulation (EU)
2019/2024 – Ecodesign direct sales
refrigerators
(BS) ISO 23953-1:2015
(BS) ISO 23953-2:2015
Restriction of Hazardous Substances Directive (RoHS) 2015/863 amending Annex II to Directive 2011/65/EU| Electrical Safety
EN 60335-1:2012 +A11:2014 +A13:2017 +A1:2019 +A14:2019 +A2:2019EN
60335-2-89:2010 +A1:2016 +A2:2017 EN 62233:2008
Electromagnetic Compatibility
EN IEC 61000-6-1: 2019
EN IEC 61000-6-3: 2021
Producer Name| Polar

I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and Standard(s).

Date 9th  May 2023
Signature ![POLAR CD229-A Refrigerated Display Merchandiser - icon

3](https://manuals.plus/wp-content/uploads/2023/06/POLAR-CD229-A-Refrigerated- Display-Merchandiser-icon-3.png)
Full Name| Ashley Hooper| Eoghan Donnellan| Brendan Denmead
Position| Technical & Quality Manager| Commercial Manager/ Importer| Commercial Manager/ Responsible Supplier
Producer Address| Fourth Way, Avon mouth, Bristol,
BS11 8TB United Kingdom| Unit 9003, Blarney Business Park, Blarney, Co. Cork
Ireland| 15 Bag dally Road, Campbelltown NSW 2560

POLAR CD229-A Refrigerated Display Merchandiser - qr
code http://www.polar- refrigerator.com/
CD229-A_CD230-A_A5_v4_2023/05/31

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals