SIP INDUSTRIAL 05641 10 Inch Portable Ventilator User Manual

June 3, 2024
SIP INDUSTRIAL

INDUSTRIAL 05641 10 Inch Portable Ventilator
User Manual

SIP INDUSTRIAL 05641 10 Inch Portable Ventilator -

05641 10 Inch Portable Ventilator

Please read and fully understand the instructions in this manual before operation. Keep this  manual safe for future reference.
SAFETY SYMBOLS USED THROUGHOUT THIS MANUAL
Danger/Caution:
Indicates risk of personal injury and/or the possibility of damage.
Warning: Risk of electrical injury or damage.
Note: Supplementary information.

SAFETY INSTRUCTIONS

IMPORTANT: Please read the following instructions carefully, failure to do so could lead to serious personal injury and / or damage to the fan.
When using your ventilator fan, basic safety precautions should always be followed to reduce the risk of fire, electric shock, personal injury and /or damage to the fan. Read all of these instructions before operating the fan and save this user manual for future reference.
The fan should not be modified or used for any application other than that for which it was designed; It was designed to safely and quietly move air in large volumes. If you are unsure of its relative applications do not hesitate to contact us and we will be more than happy to advise you.
Before operating the fan always check no parts are broken, that all screws are completely tight and that no parts are missing.
Always operate the fan safely and correctly.

KNOW YOUR FAN: Read and understand the owner’s manual and labels affixed to the fan. Learn its applications and limitations, as well as the potential hazards specific to it. DO NOT USE THE FAN IN DANGEROUS ENVIRONMENTS: Do not use your fan in damp or wet locations, or expose it to rain. Always provide adequate space around the ventilator fan.
STAY ALERT: Always watch what you are doing and use common sense when placing and operating the fan.
DISCONNECT THE FAN FROM THE MAINS SUPPLY: When not in use.
NEVER LEAVE THE FAN UNATTENDED: During operation.

SAFETY INSTRUCTIONS….cont
DO NOT ABUSE THE MAINS LEAD: Never pull the mains lead it to remove the plug from the mains socket, or to move the fan from place to place. Keep the mains lead away from heat, oil and sharp edges. If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid unwanted hazards.
HAVE YOUR FAN REPAIRED BY A QUALIFIED PERSON: The fan is in accordance with the relevant safety requirements. Repairs should only be carried out by ualified persons using original spare parts, otherwise this may result in onsiderable danger to the user and void the warranty.
USE RECOMMENDED PARTS ONLY: Unapproved and untested parts may be dangerous and will invalidate the warranty.

  • DANGER! Check that the fan is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
  • WARNING! Only operate on a level and stable surface.
  • WARNING! Do not allow untrained persons to operate the fan and do not operate the fan without all covers etc. correctly fitted.
  • WARNING! RISK OF ELECTRIC SHOCK. Do not expose the fan to water spray, rain, dripping water or moisture of any kind.
  • Do not leave the machine unattended when in use. Switch the machine off and unplug from the mains supply before leaving the work area.
  • Do not allow children or animals near the ventilator fan, particularly when in use.
  • Ensure that the ventilator fan is correctly turned off when not in use and store in a safe, dry area, out of reach of children.
  • Keep all combustible materials away from this ventilator fan.
  • Never stand on the fan.
  • DO NOT dismantle, modify or tamper with the fan, this may be dangerous and will invalidate the warranty.

WARNING: Risk of Electric Shock!

  • Use only the electrical power (voltage and frequency) specified on the model plate of the ventilator fan. If in doubt contact the manufacturer.
  • Use only a three-prong UK, grounded outlet.
  • Do not touch the fan when your hands are wet.
  • Those who are not qualified electricians should not disassemble, repair or rebuild the fan.
  • DO NOT unplug the fan by holding the cable cord; Unplug by holding the plug.
  • DO NOT use the fan when there is damage to the cable cord or plug.
  • DO NOT use the fan close to fires.
  • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

SAFETY INSTRUCTIONS….cont

  • DO NOT use the fan outdoors.
  • Always check all guards to make sure they are secure before starting the fan.
  • Never insert fingers or any other object/s through the grill guard when the fan is in operation.
  • Never leave the fan unattended and ensure that children and pets are kept a safe distance from the fan.
  • Turn the fan off and disconnect it from the mains supply when moving from one location pairs, maintenance or cleaning.
  • Do not use petrol or other corrosive liquids for cleaning as they may damage the fan or outer casing.
  • Never modify the fan in any way.
  • Never operate the fan without all guards in place.
  • Before each use; always check that the moving parts move freely and do not catch or bind.
  • Stop operation immediately if abnormalities are noticed.
  • Always clear the surface around where the fan is to be used to avoid unwanted dust or debris being pulled through the fan.

If a problem with the ventilator fan is experienced, or if the mains lead or plug become damaged, contact your distributor for repair.
If the fan is used in a place of work all rules and laws etc. relating to the use of portable electrical  appliances should be  followed.
CAUTION: The warnings and cautions mentioned in this user manual can not cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be applied.

ELECTRICAL CONNECTION
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe.
You must inspect power cables, plugs, sockets and any other connectors for wear or damage.
You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.

ELECTRICAL CONNECTION….cont
A residual current circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a residual current device (RCD) is used. It is   articularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician.
Connecting to the power supply:
This SIP ventilator fan is fitted with a standard 230v ~ 13 amp type plug. Before using the ventilator fan, inspect the mains lead and plug to ensure that neither are damaged.  f any damage is visible have the ventilator fan inspected / repaired by a  suitably qualified person. If it is necessary to replace the plug a heavy duty impact resistant plug would be preferable.
The wires for the plug are coloured in the following way:

 Yellow / Green Earth
Blue Neutral
Brown Live

As the colours of the wires may not correspond with the markings in your plug, proceed as follows: The wire which is coloured blue, must be connected to the terminal  arked with N or coloured black. The wire which is coloured brown, must be connected to the terminal, which is marked L or coloured red. The wire which is coloured  ellow   green should be connected to the terminal which is coloured the same or marked . ****

Always secure the wires in the plug terminal carefully and tightly. Secure the cable in the cord grip carefully.
Warning: Never connect live or neutral wires to the earth terminal of the plug.
Only fit an approved plug with the correct rated fuse. If in doubt consult a qualified electrician.
Note: Always ensure the mains supply is of the correct voltage and the correctuse protection is used. In the event of replacing the fuse always replace the fuse with the same value as the original.

ELECTRICAL CONNECTION….cont

Note: If an extension lead is required in order to reach the mains supply; ensure that this too is rated for the correct voltage and fuse rating.
Note: The cross section of the extension lead should be checked so that it is of sufficient size so as to reduce the chances of voltage drops.

TECHNICAL SPECIFICATION

Item No. 5641 5643
Supply 230v 50Hz 230v 50Hz
Power 300 watts 500 watts
Fan Ø 250mm 300mm
Hose Ø (optional) 05642 – 253mm 05644 – 303mm
Fan Speed 2800rpm 2800rpm
Air Flow – Maximum 45m³/Min 65m³/Min
Noise 66dB(A) 69dB(A)
Dimensions (H x L x D1 x D) 60 x 350 x 310 x 253mm 430 x 380 x 375 x 303mm
Protection IP4X IP4X

GUARANTEE

Guarantee:
This SIP ventilator fan is covered by a 12 month parts and labour warranty covering failure due to manufacturers defects. This does not cover failure due to  misuse or op-rating the fan outside the scope of this manual – any claims deemed to  be outside the scope of the warranty may be subject to charges Including, but not limited to parts,  abour and carriage costs. Consumables items such as fuses are not covered by the warranty.
In the unlikely event of warranty claims, contact your distributor as soon as possible. Proof of purchase will be required before any warranty can be honoured.
Note: Proof of purchase will be required before any warranty can be honoured.

CONTENTS & ACCESSORIES

1x Ventilator fan.
1x Instruction Manual.
Note: If any of the above are missing or damaged, contact your distributor immediately.
GETTING TO KNOW YOUR VENTILATOR FAN

SIP INDUSTRIAL 05641 10 Inch Portable Ventilator -
Fig4

Ref. Description
A Carry handle
B ON / OFF switch
C Foot
D Fan Fan blade
E Gril Grille

OPERATING INSTRUCTIONS

The portable ventilator can be used as a stand alone ventilator, or with hose / ducting attached (not supplied).
Optional extra: 05642 5m x 10” Hose and 05644 5m x 12” Hose.
Attach the hose as shown in Fig. 1. Ensure that the hose is fully secure so that there are no air leaks.
To operate the ventilator:
Connect the plug to the mains supply. Switch the ventilator on using the ON / OFF toggle switch. Fig. 2.
Note: For best performance, the maximum hose length for each ventilator is 10 metres.

SIP INDUSTRIAL 05641 10 Inch Portable Ventilator -
Fig1

Always be aware of the direction of air flow.
EXPLODED DIAGRAM

SIP INDUSTRIAL 05641 10 Inch Portable Ventilator - Fig

PARTS LIST

10″ & 12″ Ventilator 05641 05643:

1 Screw 13
2 Safety Grille 14
3 Impeller 15
4 Woodruff Key 16, 17, 18
5, 6, 7 Motor Fixings 19, 20, 21
8 Motor 22
9 Air-duct 23
10, 11,  12 Handle Fixings

UK – DECLARATION OF CONFORMITY
Declaration of Conformity
We
SIP (Industrial Products) Ltd
Gelders Hall Road
Shepshed
Loughborough
Leicestershire
LE12 9NH
As the manufacturer within the UK, England, Scotland & Wales, declare that the SIP 10″ Portable Ventilator – SIP Part No. 05641 SIP 12″ Portable Ventilator – SIP Part No. 05643 Conforms to the requirements of the following regulation(s), as indicated.
Electromagnetic Compatibility Regulations 2016
Electrical Equipment (Safety) Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
BS EN 55014-1:2006/A2:2011
BS EN 55014-1:2017
BS EN 55014-2:1997/A2:2008
BS EN 55014-2:2015
BS EN 61000-3-2:2014
BS EN 61000-3-3:2013
BS EN 60034-1:2010
BS EN IEC 60034-5:2020

DECLARATION OF CONFORMITY

Declaration of Conformity
We
SIP (Machinery Europe) Ltd
ASM Chartered Accountants
First Floor Block One
Quayside Business Park
Dundalk
County Louth
Republic of Ireland
As the manufacturer’s authorised representative within the EC declare that the 10” Portable Ventilator – SIP Part. No. 05641 2” Portable Ventilator – SIP Part No. 05643 Suppliers Part No. CTF30 Suppliers Part. No. CTF25
Conforms to the requirements of the following directive(s), as indicated:

2014/35/EU
2014/30/EU
2011/65/EU & 2015/8| Low Voltage Directive
EMC Directive
RoHS Directive
63/EU
---|---

And the following harmonised standard(s)
EN 55014-1:2006/A2:2011
EN 55014-1:2017
EN 55014-2:1997/A2:2008
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 60034-1:2010
EN IEC 60034-5:2020
Signed:
Mr P. Ippaso – Managing Director – SIP (Industrial
Products) Ltd Date: 27/09/2021.

****Please dispose of packaging for the product in a responsiblemanner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip  and place into the appropriate recycling bin.
Never dispose of electrical equipment or batteries in with your domestic waste. If your supplier offers a disposal facility please use it or alternatively use a recognised recycling  agent. This will allow the recycling of raw materials and help protect the environment.

FOR HELP OR ADVISE ON THIS PRODUCT
PLEASE CONTACT YOUR

DISTRIBUTOR, OR SIP DIRECTLY ON:
TEL: 01509500400
EMAIL: [email protected] or technical @sip-group.com
www.sip-group.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SIP INDUSTRIAL User Manuals

Related Manuals