SIP INDUSTRIAL 05645 16 Inch Air Ventilator User Manual
- June 3, 2024
- SIP INDUSTRIAL
Table of Contents
- 05645 16 Inch Air Ventilator
- SAFETY SYMBOLS USED THROUGHOUT THIS MANUAL
- SAFETY INSTRUCTIONS
- ELECTRICAL CONNECTION
- TECHNICAL SPECIFICATION
- GUARANTEE
- CONTENTS & ACCESSORIES
- GETTING TO KNOW YOUR VENTILATOR FAN
- OPERATING INSTRUCTIONS
- EXPLODED DIAGRAM
- UK – DECLARATION OF CONFORMITY
- DECLARATION OF CONFORMITY
- Documents / Resources
05645 16 Inch Air Ventilator
User Manual
05645 16 Inch Air Ventilator
Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference
SAFETY SYMBOLS USED THROUGHOUT THIS MANUAL
Danger / Caution: Indicates a risk of personal injury and/or the
possibility of damage.
Warning : Risk of electrical injury or damage.
Note : Supplementary information.
SAFETY INSTRUCTIONS
IMPORTANT : Please read the following instructions carefully, failure to
do so could lead to serious personal injury and/or damage to the fan.
When using your ventilator fan, basic safety precautions should always be
followed to reduce the risk of fire, electric shock, personal injury and/or
damage to the fan.
Read all of these instructions before operating the fan and save this user
manual for future reference.
The fan should not be modified or used for any application other than that for
which it was designed; It was designed to safely and quietly move air in large
volumes.
If you are unsure of its relative applications do not hesitate to contact us
and we will be more than happy to advise you.
Before operating the fan always check no parts are broken, that all screws are
completely tight and that no parts are missing.
Always operate the fan safely and correctly.
KNOW YOUR FAN: Read and understand the owner’s manual and labels affixed
to the fan. Learn its applications and limitations, as well as the potential
hazards specific to it. DO NOT USE THE FAN IN DANGEROUS ENVIRONMENTS: Do not
use your fan in damp or wet locations, or expose it to rain. Always provide
adequate space around the ventilator fan.
STAY ALERT: Always watch what you are doing and use common sense when placing
and operating the fan.
DISCONNECT THE FAN FROM THE MAINS SUPPLY: When not in use.
NEVER LEAVE THE FAN UNATTENDED: During operation.
DO NOT ABUSE THE MAINS LEAD: Never pull the mains lead to remove the plug
from the mains socket, or to move the fan from place to place. Keep the mains
lead away from heat, oil, and sharp edges. If the mains lead is damaged, it
must be replaced by the manufacturer or its service agent, or a similarly
qualified person in order to avoid unwanted hazards.
HAVE YOUR FAN REPAIRED BY A QUALIFIED PERSON: The fan is in accordance with
the relevant safety requirements. Repairs should only be carried out by
qualified persons using original spare parts, otherwise, this may result in
considerable danger to the user and void the warranty.
USE RECOMMENDED PARTS ONLY: Unapproved and untested parts may be
dangerous and will invalidate the warranty.
- DANGER! Check that the fan is in sound condition and in good working order. Take immediate action to repair or replace damaged parts.
- WARNING! Only operate on a level and stable surface.
- WARNING! Do not allow untrained persons to operate the fan and do not operate the fan without all covers etc. correctly fitted.
- WARNING! RISK OF ELECTRIC SHOCK. Do not expose the fan to water spray, rain, dripping water, or moisture of any kind.
- Do not leave the machine unattended when in use. Switch the machine off and unplug it from the main supply before leaving the work area.
- Do not allow children or animals near the ventilator fan, particularly when in use.
- Ensure that the ventilator fan is correctly turned off when not in use and stored in a safe, dry area, out of reach of children.
- Keep all combustible materials away from this ventilator fan.
- Never stand on the fan.
- DO NOT dismantle, modify or tamper with the fan, this may be dangerous and will invalidate the warranty.
WARNING : Risk of Electric Shock!
-
Use only the electrical power (voltage and frequency) specified on the model plate of the ventilator fan. If in doubt contact the manufacturer.
-
Use only a three-prong UK, grounded outlet.
-
Do not touch the fan when your hands are wet.
-
Those who are not qualified electricians should not disassemble, repair or rebuild the fan.
-
DO NOT unplug the fan by holding the cable cord; Unplug it by holding the plug.
-
DO NOT use the fan when there is damage to the cable cord or plug.
-
DO NOT use the fan close to fires.
To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. -
DO NOT use the fan outdoors.
-
Always check all guards to make sure they are secure before starting the fan.
-
Never insert fingers or any other object/s through the grill guard when the fan is in operation.
-
Never leave the fan unattended and ensure that children and pets are kept a safe distance from the fan.
-
Turn the fan off and disconnect it from the main supply when moving from one location to another.
-
Turn the fan off and disconnect it from the mains supply when carrying out any repairs, maintenance or cleaning.
-
Do not use petrol or other corrosive liquids for cleaning as they may damage the fan or outer casing.
-
Never modify the fan in any way.
-
Never operate the fan without all guards in place.
-
Before each use; always check that the moving parts move freely and do not catch or bind.
-
Stop operation immediately if abnormalities are noticed.
-
Always clear the surface around where the fan is to be used to avoid unwanted dust or debris being pulled through the fan.
If a problem with the ventilator fan is experienced, or if the main lead or
plug becomes damaged, contact your distributor for repair.
If the fan is used in a place of work all rules and laws etc. relating to the
use of portable electrical appliances should be followed.
CAUTION : The warnings and cautions mentioned in this user manual can not cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors that cannot be built into this product but must be applied.
ELECTRICAL CONNECTION
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following:
You must check all electrical products, before use, to ensure that they are
safe.
You must inspect power cables, plugs, sockets, and any other connectors for
wear or damage.
You must ensure that the risk of electric shock is minimized by the
installation of appropriate safety devices.
A residual current circuit Breaker (RCCB) should be incorporated into the main
distribution board. We also recommend that a residual current device (RCD) is
used. It is particularly important to use an RCD with portable products that
are plugged into a supply that is not protected by an RCCB. If in any doubt
consult a qualified electrician.
Connecting to the power supply:
This SIP ventilator fan is fitted with a standard 230v ~ 13 amp type plug.
Before using the ventilator fan, inspect the mains lead and plug to ensure
that neither is damaged. If any damage is visible have the ventilator fan
inspected/repaired by a suitably qualified person. If it is necessary to
replace the plug a heavy-duty impact-resistant plug would be preferable.
The wires for the plug are colored in the following way:
Yellow / Green | Earth |
---|---|
Blue | Neutral |
Brown | Live |
As the colours of the wires may not correspond with the markings in your plug,
proceed as follows: The wire which is coloured blue must be connected to the
terminal marked with N or coloured black. The wire which is coloured brown
must be connected to the terminal, which is marked L or coloured red. The wire
which is coloured yellow/green should be connected to the terminal which is
coloured the same or marked .
Always secure the wires in the plug terminal carefully and tightly. Secure the
cable in the cord grip carefully.
Warning : Never connect live or neutral wires to the earth terminal of
the plug.
Only fit an approved plug with the correct rated fuse. If in doubt consult a
qualified electrician.
Note : Always ensure the mains supply is of the correct voltage and the
correct fuse protection is used. In the event of replacing the fuse always
replace the fuse with the same value as the original.
Note : If an extension lead is required in order to reach the mains
supply; ensure that this to is rated for the correct voltage and fuse rating.
Note : The cross-section of the extension lead should be checked so that
it is of sufficient size so as to reduce the chances of voltage drops.
TECHNICAL SPECIFICATION
Item No | 5645 |
---|---|
Supply | 230v 50Hz |
Power | 1100Watts |
Fan Ø | 16” / 400mm |
Hose Ø (Optional) | 05646 – 403mm |
Fan Speed | 2800rpm |
Air Flow – Maximum | 120m ³/Min |
Noise | 79dB(A) |
Dimensions – (H x L x D1 x D) | 530 x 450 x 480 x 403mm |
Protection | IPX4 |
GUARANTEE
Guarantee:
This SIP ventilator fan is covered by 12-month parts and labour warranty
covering failure due to manufacturers’ defects.
This does not cover failure due to misuse or operating the fan outside the
scope of this manual – any claims deemed to be outside the scope of the
warranty may be subject to charges Including, but not limited to parts, labour
and carriage costs.
Consumables items such as fuses are not covered by the warranty.
In the unlikely event of warranty claims, contact your distributor as soon as
possible.
Proof of purchase will be required before any warranty can be honoured.
Note : Proof of purchase will be required before any warranty can be
honoured.
CONTENTS & ACCESSORIES
1x Ventilator fan.
1x Instruction Manual.
Note : If any of the above are missing or damaged, contact your
distributor immediately.
GETTING TO KNOW YOUR VENTILATOR FAN
Ref: | Description |
---|---|
A | Fan |
B | Grille |
C | ON / OFF Switch |
D | Frame |
E | Swivel Locking Knob |
F | Castor Wheel |
G | Locking Castor Wheel |
OPERATING INSTRUCTIONS
The portable ventilator can be used as a stand-alone ventilator, or with hose
/ ducting attached (not supplied).
Optional extra: 05646 10m x 16” Hose Ducting.
Attach the hose as shown in Fig. 1. Ensure that the hose is fully secure so
that there are no air leaks.
To operate the ventilator:
Connect the plug to the main supply.
Lock the castor wheels to prevent movement during use. Fig. 2.
Adjust the ventilator angle as required. Fig. 3.
Switch the ventilator on using the ON / OFF lever switch. Fig. 4. Always be aware of the direction of airflow.
EXPLODED DIAGRAM
PARTS LIST
16″ Ventilator 05645
1| Screw
2| Safety Grille
3| Impeller
4| Woodruff Key
5, 6, 7| Motor Fixings
8| Motor
9| Air-duct
10| Switch
11| Hand Wheels
12| Frame
13| Castors
14, 15, 16| Castor Fixings
17, 18, 19| Impeller Fixings
NOTES
UK – DECLARATION OF CONFORMITY
Declaration of Conformity
We
SIP (Industrial Products) Ltd
Gelders Hall Road
Shepshed
Loughborough
Leicestershire
LE12 9NH
England
As the manufacturer within the UK, England, Scotland & Wales,
declare that the
SIP 16″ Portable Ventilator – SIP Part No. 05645
Conforms to the requirements of the following regulation(s), as
indicated.
Electromagnetic Compatibility Regulations 2016
Electrical Equipment (Safety) Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
BS EN 55014-1:2006/A2:2011
BS EN 55014-1:2017
BS EN 55014-2:1997/A2:2008
BS EN 55014-2:2015
BS EN 61000-3-2:2014
BS EN 61000-3-3:2013
BS EN 60034-1:2010
BS EN IEC 60034-5:2020
Signed:
Mr P. Ippaso – Director – SIP (Industrial Products)
Ltd Date: 27/09/2021
DECLARATION OF CONFORMITY
Declaration of Conformity
We
SIP (Machinery Europe) Ltd
ASM Chartered Accountants
First Floor Block One
Quayside Business Park
Dundalk
County Louth
Republic of Ireland
As the manufacturer’s authorised representative within the EC declare that the
16” Portable Ventilator – SIP Part. No. 05645 Suppliers Part. No. CTF40
Conforms to the requirements of the following directive(s), as indicated.
2014/35/EU | Low Voltage Directive |
---|---|
2014/30/EU | EMC Directive |
2011/65/EU & 2015/863/EU | RoHS Directive |
And the following harmonised standard(s)
EN 55014-1:2006/A2:2011
EN 55014-1:2017
EN 55014-2:1997/A2:2008
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 60034-1:2010
EN IEC 60034-5:2020
Signed:
**** Mr P. Ippaso – Managing Director – SIP (Industrial
Products) Ltd Date: 27/09/2021.
Please dispose of the packaging for the product in a responsible manner. It is
suitable for recycling. Help to protect the environment, take the packaging to
the local amenity tip and place it into the appropriate recycling bin.
**** Never dispose of electrical equipment or batteries in your domestic
waste. If your supplier offers a disposal facility please use it or
alternatively use a recognised recycling agent. This will allow the recycling
of raw materials and help protect the environment.
FOR HELP OR ADVICE ON THIS PRODUCT PLEASE CONTACT YOUR
DISTRIBUTOR, OR SIP DIRECTLY ON:
TEL: 01509500400
EMAIL:sales@sip-group.com or technical@sip-
group.com
www.sip-group.com
Ref: 27SEPT2021 version 2
Documents / Resources
| SIP
INDUSTRIAL 05645 16 Inch Air
Ventilator
[pdf] User Manual
05645 16 Inch Air Ventilator, 16 Inch Air Ventilator, 16 Inch Ventilator, Air
Ventilator, 05645, 05645 Air Ventilator, 05645 Ventilator
---|---
References
- Group Publishing
- SIP Industrial Products Official Website - SIP Industrial Products Official Website
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>