MINKA 718212840351 52″ Ceiling Fan for Indoor Location Instruction Manual
- June 7, 2024
- MINKA
Table of Contents
- SAFETY RULES
- PACKAGE CONTENTS
- INSTALLING THE FAN
- HANGING THE FAN
- ELECTRICAL CONNECTIONS
- INSTALLING THE CANOPY AND CANOPY COVER
- INSTALLING THE BLADE TO THE FLYWHEEL
- INSTALLING THE 16W LED ASSEMBLY
- OPERATING THE REMOTE CONTROL
- CARE OF YOUR FAN
- TROUBLESHOOTING
- SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Galeventi
READ AND SAVE ALL INSTRUCTIONS
52″ Ceiling Fan for Indoor Location
INSTRUCTION MANUAL WARRANTY CERTIFICATE
02020Minka LigMing, Inc. Manual design and all elements of manual design are
protected by U.S. Federal and/or State Law, including Patent, Trademark,
and/or copyright laws.
1151 W. Bradford Court, Corona, CA 92882 • For Customer Assistance Call:
1-800-307-3267
WARRANTY
The Minka warranty Is for one (1) year from the date of purchase from an authorized Minka dealer. This warranty Is only valid to the original purchaser or user against all defects In material and workmanship (light bulbs excluded) for one (1) full year. Additionally, Minka warrants the motor only for the lifetime of the Minka ceiling fan (excluding wall controls and electrical components), to the original purchaser or user.
- The warranty is void with the use of any non-Minka electrical devices; e.g., wall controls or electrical dimmer switches, etc.
- The warranty Is void once the original purchaser or user ceases to own the fan or the fan Is moved from its original point of installation.
- The warranty Is void with the use of any hanger bracket (non-Minka or non-fan specific) other than the hanger bracket supplied in the box.
- The warranty is void if installed in an environment other than its intended use (Indoor fans installed outdoors or in a covered outdoor patio area, or subjected to environmental conditions: salt air, humidity, direct sun exposure, etc.). Outdoor finishes are specifically excluded from the terms of this warranty since they are subject to environmental and maintenance damages beyond our control.
WARRANTY SERVICE INFORMATION
To obtain warranty service during the warranty period, the purchaser should
return the fan with the original sales receipt to the original place of
purchase. Replacement is subject to the availability of the same model. This
is a limited warranty; the original purchaser or user is responsible for the
cost of removal and re-installation of repaired or replacement products.
Outdoor finishes are specifically excluded from the terms of this warranty
since they are subject to environmental and maintenance damages beyond our
control. Fan warranty registration should be mailed as addressed on the
warranty card.
Date Purchased……….
Serial Number…………
Store Purchased………………… Model Numbe: 84035/84036/84037
SAFETY RULES
- To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.
- All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-1999” and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
- The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs. Use only UL-listed outlet boxes marked “FOR FAN SUPPORT.”
- The fan must be mounted with a minimum of 7 ft. clearance from the trailing edge of the blades to the floor.
- Avoid placing objects in the path of the blades.
- To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
- Do not use water or detergents when cleaning the fan or fan blades. Dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
- After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
- All setscrews must be checked and retightened where necessary before installation.
- Turn the fan off and wait for the blades to stop completely before performing any maintenance or cleaning.
NOTE: The important safeguards and instructions appearing in this manual
are not meant to cover all possible conditions and situations that may occur.
It must be understood that common sense, caution and care are factors that
cannot be built into this product These factors must be supplied by the person
(s) installing, caring for and operating the unit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR OTHER PERSONAL INJURY, MOUNT
FAN ONLY ON AN OUTLET BOX OR SUPPORTING SYSTEM MARKED ACCEPTABLE FOR FAN
SUPPORT OF 35 LBS (15.9 KG) OR LESS AND USE MOUN11NG SCREWS PROVIDED WITH THE
OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGH11NG
FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED.
CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE HOLDERS WHILE
INSTALLING, BALANCING THE BLADES, OR CLEANING THE FAN. DO NOT INSERT FOREIGN
OBJECTS BETWEEN ROTATING FAN BLADES.
TO REDUCE THE RISK OF FIRE OR ELECTRONIC SHOCK, THIS FAN ONLY CAN USE DL-
1167RYS-02 SOLID-STATE SPEED CONTROL WITH R-41035 REMOTE CONTROL ONLY.
PACKAGE CONTENTS
Unpack your fan and check the contents. You should have the following items:
- Fan blades (5)
- Blade holder (5)
- Hanger bracket
- Canopy
- Canopy cover
- Standard download assembly(6″)
- Coupling cover
- Fan motor assembly
- Flywheel (preassembled) (1)
- 16W LED assembly
- Receiver(1) + wire nut (6)
- Transmitter + holder + 2 mounting screws + 12 V battery
A. Blade attachment hardware: 3/6″ x 18mm blade screw ( 15 + 1 spare) ,Fiber
washer ( 15 + 1 spare)
B. Wire nut (3)
C. Balancing kit
INSTALLING THE FAN
Toots Required: Phillips screwdriver, slotted screwdriver; step-ladder, wire
cutters; electrical tape.
MOUNTING OPTIONS
If there isn’t an existing mounting box, then read the following
instructions. Disconnect the power by removing fuses or turning off circuit
breakers.
Secure the outlet box directly to the building structure. Use appropriate
fasteners and building materials. The outlet box and its support must be able
to fully support the moving weight of the fan (at least 35 lbs.). Use a UL
Listed metal outlet box. Do not use a plastic outlet box.
Figures 1, 2, and 3 are examples of different ways to mount the outlet box.
Note: You may need a longer downlrod to maintain proper blade clearance
when Installing on a steep, sloped ceiling. Longer downloads are available
from your Minka dealer.
To hang your fan where there is an existing fixture but no ceiling Joist, you
may need to install a hanger bar as shown in Fig. 4 (available at your Minka
dealer).
HANGING THE FAN
WARNING: All of the parts, hardware, and components such as the hanger
bracket and hanger ball have been provided for your safety and the proper
installation of your new ceiling fan. The use of other parts, hardware or
components not supplied by Minka with the fan will void the Minka Warranty.
REMEMBER to turn off the power. Follow the steps below to hang your fan
properly:
Step 1. Secure the Hanger Bracket to the ceiling outlet box using the screws
provided with your outlet box in conjunction. (Fig. 5)
Step 2. Loosen the two Set Screws and remove the Hitch Pin and Lock Pin from
the coupling located on The top of the Motor Assembly. (Fig.6)
Step 3. Remove the Hanger Ball from the Downrod Assembly by loosening the Set
Screw and removing the Cross Pin. (Fig.7) Step 4. Carefully feed fan wires up
through the downlrod. (Fig. 8 ) Thread Downrod into the Coupling until the
holes are lined up and secure with the Lock Pin and Hitch Pin previously
removed, tighten Set Screws. (Fig. 9) Step 5. Slip coupling cover, canopy
cover, and canopy onto downlrod. (Fig. 9 ) Carefully reinstall hanger ball
onto rod being sure that cross pin is in the correct position, set screws are
tightened and wires are not twisted.
Step 6. Lift the Motor Assembly and place The Hanger Ball into the Hanger
Bracket. Rotate the Motor Assembly as needed until the check groove from the
Hanger Ball seats firmly over the registration slot from the Hanger Bracket.
(Fig.10)
ELECTRICAL CONNECTIONS
WARNING: To avoid possible electrical shock be sure electricity is turned
off at the main fuse or breaker box before wiring. NOTE: This remote control
unit is equipped with 16 code combinations to prevent possible interference
from or to other remote units. The frequency switches on your receiver and
remote control have been preset at the factory. Please recheck to make sure
the switches on the remote control and the receiver are set to the same
position (Fig.11 ). Any combination of settings will operate the fan as long
as the switches in the remote control and receiver are set to the same
position.
Step 1. Insert Receiver into Hanger Bracket with the flat side of the Receiver
facing the ceiling. (Fig.12 )
Step 2. Motor to Receiver Electrical Connections: Connect the WHITE wire from
the fan to the WHITE wire marked “TO MOTOR N” from the Receiver. Connect the
BLACK wire from the fan to the BLACK wire marked “TO MOTOR L” from the
Receiver. Connect the BLUE wire from the fan to the BLUE wire marked ”
DOWNLIGHT ” from the Receiver. (Fig.13) NOTE: Fan must be installed from a
maximum distance of 40 feet from the transmitting unit for proper signal
transmission between the transmitting unit and the fan’s receiving unit.
Step 3. Receiver to House Supply Wires Electrical Connections: Connect the
WHITE wire (Neutral) from the outlet box to the WHITE wire marked “AC in N”
from the receiver. Connect the BLACK wire (Hot) from the outlet box to the
BLACK wire marked “AC in L” from the receiver. Secure all wire connections
with the plastic wire nuts provided. (Fig.13 )
Step 4. Connect the ground wire (green or bare copper) from the outlet box to
the ground wire of the hanging ball and the ground wire of the mounting
bracket. Secure wire connection with the plastic wire nut provided. (Flg.13)
After all splices are made, check to make sure there are no loose strands. As
an additional precaution, we suggest securing the plastic wire connectors to
the wires with electrical tape.
Note: After making electrical connections, spliced conductors should be
turned upward and pushed carefully up Into the outlet box. The wires should be
spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and the ungrounded conductor on the other side
of the outlet box.
INSTALLING THE CANOPY AND CANOPY COVER
Step 1. Remove 1 of the 2 screws from the bottom of the hanger bracket and
loosen the other half a turn from the screw head. (Fig.14)
Step 2. Slide the canopy up towards the hanger bracket and place the keyhole
on the canopy over the screw on the hanger bracket, turn the canopy until it
locks in place at the narrow section of the keyhole.
Step 3. Align the circular hole on the canopy with the remaining hole on the
hanger bracket, secure by tightening the two set screws. Note: Adjust the
canopy screws as necessary until the canopy and canopy cover is snug.
INSTALLING THE BLADE TO THE FLYWHEEL
Insert the blade through the slot on the flywheel. Starting from the center hole, fasten the blade to the flywheel by using the blade screw and fiber washer(Fig.15-a). Align the blade holder to the blade (as shown In FIg.15-b) and secure using two blade screws and two fiber washers. Repeat this step for the other four blades.
INSTALLING THE 16W LED ASSEMBLY
CAUTION: To Reduce The Risk 01 Electric Shock, Disconnect The Electrical
Supply Circuit To The Fan Before Installing The Light Kit.
Step 1. While holding the 16W LED assembly under your fan, firmly snap the
wire connection plugs together.
Step 2. Attach the 16W LED assembly to the switch box by twisting tightly.
NOTE: This is an integrated LED light kit assembly and can not be
disassembled to prevent electronic shock.
OPERATING THE REMOTE CONTROL
Remote Control only: Install an A23 12-volt battery (included). (Fig. 17) To
prevent damage to the transmitter remove The battery if not used for long
periods of time.
Restore Power to Ceiling Fan.
Turns the light on or off and also controls the brightness setting. Press and
release this button to turn the light on or off. Press and hold the button to
set the desired brightness. The light button has an auto-resume, it will stay
at the same brightness as the last time it was turned off.
Speed settings for summer or winter weather depend on factors such as room
size, ceiling height and the number of fans. The reverse switch Is located
under the coupling cover (Figure 20). Slide the switch to left for warm
weather operation. Slide the switch to the right for cool weather operation.
NOTE: Wait for fan to stop before changing the setting of the slide
switch.
Summer Weather (counter-clockwise blade rotation) A DOWNWARD airflow creates a
cooling effect as shown in Figure 22. This allows you to set your air
conditioner in a warmer setting without affecting your comfort.
Winter Weather (Clockwise blade rotation) An UPWARD airflow moves warmer air
off the ceiling area as shown in Figure 21. This allows you to set your
heating unit on a cooler setting without affecting your comfort.
CARE OF YOUR FAN
Here are some suggestions to help maintain your fan.
-
Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from the ceiling).
-
Clean your fan periodically to help maintain its new appearance over the year.
CAUTION : many common household cleaning products contain chemicals that could damage the finish of your fan. Use only a soft lint-free cloth and soapy water. -
ft your fan is provided with wood veneer blades; you can apply a light coat of furniture polish for additional protection and enhanced beauty. Cover small scratches with a light application of shoe polish.
-
Use a lint-free lightly damp cloth or duster to remove dust from the blades.
-
There is no need to oil your fan. The motor has permanently lubricated bearings.
-
If your fan is provided with glass shades, clean with lukewarm soapy water and a soft cloth or sponge. DO NOT IMMERSE GLASS SHADES IN HOT WATER. DO NOT PUT GLASS SHADES INTO AN AUTOMATIC DISHWASHER.
WARNING! MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT ANY REPAIRS. REFER TO THE SECTION, “ELECTRICAL CONNECTIONS”.
TROUBLESHOOTING
SYMPTOM | SOLUTION |
---|---|
Fan will not start | • Check to make sure the wall switch is turned on. |
• Check circuit fuses or breakers.
• Caution! Make sure the power is turned off before performing the following
steps.
• Remove canopy and check wire connections.
• Check wall control transmitter connections (if applicable).
• Note: Fan must be installed at a maximum distance of 40 feet from the
transmitting unit for proper signal transmission between the transmitting unit
and the fan’s receiving unit.
Fan Sounds Noisy| • Allow a 24-hour “break-in” period. Most noises associated
with a new fan will go away during this time.
• Make sure the screws that attach the fan blade holder to the motor hub is
tight. • Make sure outlet box is secured to building structure, if necessary
use the wood screws provided to further secure outlet box to joist.
• Make sure hanger bracket is secure to the outlet box, screws are tight
Fan Wobble| • NOTE: All blade sets are grouped by weight Because wood and
plastic blades vary in density, the fan may wobble even though blades are
matched.
• Make sure outlet box is secured to building structure, if necessary use the
wood screws provided to further secure outlet box to joist.
• Make sure hanger bracket is secure to the outlet box, screws are tight
• If a Balancing kit is provided follow the instructions included with the
balancing kit to help correct any excessive wobble.
The remote control is not working.| • Do not connect the fan with wall-mounted
variable speed control(s).
• Check to make sure the dip switches from the remote control and receiver are
set to the same frequency
SPECIFICATIONS
Fan Size | Speed | Volts | Amps | Watts | RPM | CFM | N.W. | G.W. | C.F. |
---|---|---|---|---|---|---|---|---|---|
52″ | Low | 120 | 0.25 | 16. | 74 | 2072 | 7.1 kgs | 8.11kgs | 1.435′ |
High | 120 | 0.48 | 57. | 160 | 4789 |
These are typical readings. Your actual fan may vary. They do not include amps and wattage used by the light(s).
Supplier’s Declaration of Conformity
47 CFR§2.1077 compliance Information
Unique Identifier
Trade name: MINKA CEILING FAN CO.
Model Number: XXXXX
Responsible Party-U.S Contact Information
Minka Group Inc.
1151 West Bradford Court.
Corona, CA 92882 Tel. 951-735-9220
FCC Compliance Statement: products subject to Part 15
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct
the interference by one or more of the following measures: Reorient or
relocate the receiving antenna. Increase the separation between the equipment
and receiver. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. Consult the dealer or an experienced
radio/TV technician for help.
For any additional information about your Minka Ceiling fan, please write to:
1151 W. Bradford Court, Corona, CA 92882 • For Customer Assistance Call:
1-800-307-3267