FRANKE FBI 537 XS Cooker Hood Instruction Manual

June 10, 2024
Franke

FRANKE FBI 537 XS Cooker Hood

FRANKE-FBI-537-XS-Cooker-Hood-product

Product Information

The product is a cooker hood or kitchen hood that is available in multiple languages including English, Italian, French, German, Greek, Russian, and Dutch. The product is designed to remove smoke, steam, and odors from the kitchen while cooking. The product comes with installation instructions to help users install it in their kitchen.

Product Usage Instructions

  1. Read the installation instructions carefully before installing the cooker hood.
  2. Select the appropriate location for installation. The cooker hood should be installed above the cooking area and should be at least 50 cm away from the cooking surface.
  3. Ensure that the cooker hood is properly anchored and secured to the wall or ceiling.
  4. Connect the cooker hood to a power source as indicated in the installation instructions.
  5. Turn on the cooker hood before cooking to ensure that it is working properly.
  6. While cooking, turn on the cooker hood to the appropriate speed to remove smoke, steam, and odors from the kitchen.
  7. After cooking, leave the cooker hood on for a few minutes to ensure that all smoke and odors are removed from the kitchen.
  8. Clean the cooker hood regularly as indicated in the user manual to ensure optimal performance.

SAFETY INFORMATION

  • For your safety and correct operation of the appliance, read this manual carefully before installation and use. Always keep these instructions with the appliance even if you move or sell it. Users must fully know the operation and safety features of the appliance.
  • The wire connection has to be done by specialized technician.
  • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please refer to the paragraphs on working dimensions and installation).
  • If the instructions for installation of the gas hob specify a greater distance, this must be respected.
  • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
  • Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
  • For Class I appliances, check that the domestic power supply guarantees adequate earthing.
  • Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
  • Regulations concerning the discharge of air have to be fulfilled.
  • Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
  • If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas.
  • When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 bar to prevent fumes being drawn back into the room by the cooker hood.
  • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent.
  • Connect the plug to a socket complying with current regulations, located in an accessible place.
  • With regards to the technical and safety measures to be adopted for fume discharging, it is important to closely follow the regulations provided by the local authorities.
  • WARNING: Before installing the Hood, remove the protective films.
  • Use only screws and small parts supplied with the hood.
  • WARNING: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.
  • Do not look directly at the light through optical devices (binoculars, magnifying glasses…
  • Do not flambe under the range hood; risk of fire.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and under-stand the hazards involved. Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • Children should be supervised to ensure that they do not play with the appliance.
  • The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
  • Accessible parts may become hot when used with cooking appliances.
  • Clean and/or replace the Filters after the specified time period (Fire hazard). See paragraph Care and Cleaning.
  • There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
  • The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

CHARACTERISTICS

Dimensions

FRANKE-FBI-537-XS-Cooker-Hood-fig-2

Components

FRANKE-FBI-537-XS-Cooker-Hood-fig-16

INSTALLATION

Fitting the Hood canopy

BEFORE FITTING THE HOOD TO THE WALL UNIT, PROCEED AS FOLLOWS:

  • Open the Panel by pulling it.
  • Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards.
  • Remove grease filters.
  • Disconnect the wires to the Commands at the connectors.
  • Disconnect the wires to the Light at the connectors.FRANKE-FBI-537-XS-Cooker-Hood-fig-7
  • Remove the frame by unfastening the 6 screws.
  • The Hood can be installed directly on the underside of the wall unit (Minimum 650 mm from the Cooker Hob).
  • Create an opening in the bottom of the wall unit, as shown.
  • Fasten using the 10 screws 12a provided.
  • Screw the Frame back into place using the 6 screws removed as described above, reconnect the wires to the Commands and Lights replace the metal grease filter and close the Panel.
Connections

AIR OUTLET DUCTING VERSION

When installing the Ducting version, join the Hood to the outlet duct using a rigid or flexible pipe 0150 or 120 mm, selection of which is at the discretion of the installation technician.

  • Insert flaps 11b on the Hood Canopy Outlet.

Connecting the o 150 pipe

  • Fasten the pipe using suitable pipe clamps. The materials required to do so are not provided.

Connecting the a 120 pipe

  • To connect using a 0120 mm pipe, insert the re-duction Flange 9 onto the Hood Canopy Outlet.
  • Fasten the pipe using suitable pipe clamps. The materials required to do so are not provided.
  • In both cases, any Activated Charcoal Filters must be removed.

RECIRCULATION VERSION AIR OUTLET

  • Cut a hole o 125 mm in any shelf that may be positioned over the hood.
  • Insert the reducer flange 9 on the hood body out-let.
  • Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe 0120 mm.
  • Fix the pipe in position using sufficient pipe clamps (not supplied).
  • Fix the air outlet grid 8 on the recirculation air outlet by using the 2 screws 12e (2,9 × 9,5) o- vided.
  • Ensure that the activated charcoal filters have been inserted.

ELECTRICAL CONNECTION

  • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm..

USE

Control panel

Button Led Function
L Turns the lights on/off at maximum strength.
T1 Fixed Turns the motor on/off at speed one.
T2 Fixed Turns the Motor on at speed two.
Press and hold the button for approximately 3 seconds, with all the loads

turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm on. The relevant LED flashes twice to confirm.

To turn the alarm off, press the button again and hold for at least 3 seconds. The relevant LED flashes once.

T3| Fixed| Turns the Motor on at speed three.
–| Press and hold the button for approximately 3 seconds, with all the loads turned off (Motor and Lights), to perform a reset of Filter saturation alarm. The LED S1 flashes three times.
T4| Fixed| Turns the Motor on at INTENSIVE Speed.

This speed is timed to run for 6 minutes. At the end of this time, the system returns automatically to the speed that was set before. If it is activated with the motor turned off, the hood will switch to OFF at the end of the time.

S1| Fixed| Signals the Metal Grease Filter saturation alarm, indicating that it is necessary to wash the filters. The alarm is triggered after the Hood has been in operation for 100 working hours.
Flashing| When this is activated, it signals the Activated Charcoal Filter saturation alarm, indicating that the filter must be changed; the Metal Grease Filters must also be washed. The Activated Charcoal Filter saturation alarm comes into operation after the Hood has been working for 200 hours.

CARE AND CLEANING

Opening Panel

  • Open the Panel by pulling it.
  • Clean the outside with a damp cloth and neutral detergent.
  • Clean the inside using a damp cloth and neutral detergent; do not use wet cloths or sponges, or jets of water; do not use abrasive substances.

Metal grease filters

These can be washed in the dishwasher, and need to be cleaned whenever the S1 Led comes on or at least once every 2 months use, or more frequently if use is particularly intensive.

CLEANING THE FILTERS

Resetting the alarm signal

  • Turn the Lights and the Suction Motor off.
  • Press T3 and hold for at least 3 seconds, until LED flashes three times in confirmation.

Cleaning the Filters

  • Open the doors.
  • Remove the Filter, pushing it towards the back of the unit and at the same time pulling downward.
  • Wash the filter without bending it, and leave it to dry thoroughly before replacing (if the surface of the filter changes colour over time, this will have absolutely no effect on its efficiency).
  • Replace, taking care to ensure that the handle faces forwards.
  • Close the doors again.

Activated Charcoal Filter (Recirculation Version)

This cannot be washed or regenerated, and must be changed when led SI starts to flash, or at least once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction motor is turned on.

Activating the alarm signal

  • In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a later date.
  • Turn the Lights and the Suction Motor off.
  • Press button T2 and hold it for 5 seconds until the LED flashes twice in confirmation: CHANGING

Resetting the alarm signal

  • Turn the Lights and the Suction Motor off.
  • Press T3 and hold for at least 3 seconds, until LED flashes three times in confirmation.

Changing the Filter

  • Open the doors.
  • Remove the Metal Grease Filter.
  • Remove the saturated Activated Charcoal Filters, as indicated (A).
  • Fit the new Filters, as indicated (B).
  • Replace the Metal grease filters.
  • Close the doors.

Lighting unit

  • For replacement contact technical support (“To purchase contact technical support”).

Franke S.p.a.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals