UBIQUITI US-48-500W Network Unifi Switch User Guide

June 6, 2024
UBIQUITI

US-48-500W, US-48-750W Quick Start Guide

Package Contents

UBIQUITI US-48-500W Network Unifi Switch ---rt

Installation Requirements

  • Phillips screwdriver
  • Standard-sized, 19″ wide rack with a minimum of 1U height available
  • For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
  • For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.
    We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable
    Note: Although the cabling can be located outdoors, the UniFi Switch itself should be housed inside a protective enclosure.
    IMPORTANT : We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power.

System Requirements

  • Linux, Mac OS X, or Microsoft Windows 7/8/10
  • Java Runtime Environment 1.6 (1.8 or newer recommended)
  • UniFi Controller v5.4.x or higher

Hardware Overview

UBIQUITI US-48-500W Network Unifi Switch -fig b

1.System LED|
---|---
UniFi – LED Color Patterns for UniFi Devices – Ubiquiti Support and Help Center for detailed descriptions.|
RJ45 PoE LED (Ports 1 – 48)|
Off| No PoE
Amber| IEEE 802.3af/802.3at
Green| 24V Passive PoE
3.RJ45 Speed/Link/Act LED (Ports 1 – 48)|
off| No Link
Amber| Link Established at 10/100 Mbps

Flashing Indicates Activity

Green| Link Established at 1000 Mbps

Flashing Indicates Activity

4.SFP+ Speed/Link/Act LED (Ports 1 – 2)
Off| No Link
Green| Link Established at 1 Gbps

Flashing Indicates Activity

White| Link Established at 10 Gbps
Flashing Indicates Activity
5. SFP Speed/Link/Act LED (Ports 1 – 2)
Off| No Link
Green| Flashing Indicates Activity
6.RJ45 (Ports 1 – 48)
RJ45 ports support Power over Ethernet (PoE) and 10/100/1000 Ethernet connections.
7.SFP+ (Ports 1 – 2)
Hot-swappable SFP+ ports support 1/10 Gbps connections.
8.3SFP (Ports 1 – 2)
Hot-swappable SFP ports support 1 Gbps connection.
9. Reset Button
This button serves two functions for the UniFi Switch:

  • Restart Press and release the Reset button quickly.
  • Restore to Factory Default Settings Press and hold the Reset button for more than ve seconds.

UBIQUITI US-48-500W Network Unifi Switch -fig 4

10. Console Port

RJ45 serial console port for Command Line Interface (CLI) management. Use an RJ45-toDB9, serial console cable, also known as a rollover cable, to connect the Console port to your computer. Then configure the following settings as needed:

  • Baud rate 115200
  • Data bits 8
  • Parity NONE
  • Stop bits 1
  • Flow control NONE

11. Power Port
Connect the included Power Cord to the Power port.

Hardware Installation

1. ![UBIQUITI US-48-500W Network Unifi Switch -fig 5](https://manuals.plus/wp- content/uploads/2021/10/UBIQUITI-US-48-500W-Network-Unifi-Switch-fig-5.png)

2.
UBIQUITI US-48-500W Network Unifi Switch -fig 6
UBIQUITI US-48-500W Network Unifi Switch -fig 7
UBIQUITI US-48-500W Network Unifi Switch -fig m
3.
UBIQUITI US-48-500W Network Unifi Switch -fig e
UBIQUITI US-48-500W Network Unifi Switch -fig h

Using SFP+ and SFP Ports

Ports SFP+ Module Type SFP Module Type
SFP+ 1-2 10 Gbps 1 Gbps
SFP 1-2 (Not supported) 1 Gbps

1.
UBIQUITI US-48-500W Network Unifi Switch -fig 8

2.
UBIQUITI US-48-500W Network Unifi Switch -fig k
3.
UBIQUITI US-48-500W Network Unifi Switch -fig rt

For information about compatible ber SFP modules, visit: community.ubnt.com/uni

Software Installation

Download and install the latest version of the UniFi Controller software at ui.com/download/uni and follow the on-screen instructions.
Note: If you already have UniFi Controller v5.4.x or higher installed, go to the section, Adopting the UniFi Switch.
After you have installed the software and run the UniFi Installation Wizard, a login screen will appear for the UniFi Controller management interface. Enter the username and password that you created and click Sign In.

UBIQUITI US-48-500W Network Unifi Switch -fig 87

You can manage your network and view network statistics using the UniFi Controller management interface.
To adopt the UniFi Switch, proceed to the section, Adopting the UniFi Switch.
For information on configuring and using the UniFi Controller software, refer to the User Guide on the website: ui.com/download/uni

Adopting the UniFi Switch

  1.  From the UniFi Controller dashboard, click Devices in the left menu bar.
    UBIQUITI US-48-500W Network Unifi Switch -fig n

  2. Locate the UniFi Switch in the list of devices under the Model column. Click Adopt.
    UBIQUITI US-48-500W Network Unifi Switch -fugh

  3. The System LED on the UniFi Switch will turn blue to confirm that it has been successfully adopted.

Configuring PoE Settings

  1.  On the Devices screen, locate the UniFi Switch. Click the switch to access its settings.
    UBIQUITI US-48-500W Network Unifi Switch -fig jk

  2.  Click the Ports tab.
    UBIQUITI US-48-500W Network Unifi Switch -fig jk

  3. Click Actions for the port you want to congure.
    UBIQUITI US-48-500W Network Unifi Switch -fig dg

  4. Select the appropriate PoE setting: Off, 24V Passive, or PoE+. Then click Apply.

UBIQUITI US-48-500W Network Unifi Switch -fig df

For more information, refer to the User Guide on the website: ui.com/download/uni

Specifications

US-48-500W/US-48-750W


Dimensions| 485 x 43.7 x 374.6 mm (19.09 x 1.72 x 14.75″)
Weight

US-48-500W

US-48-750W

| 6.1 kg (13.5 lb)

6.5 kg (14.3 lb)

Total Non-Blocking Line Rate| 70 Gbps
Max. Power Consumption

US-48-500W

US-48-750W

| 500W

750W

Power Method| 100-240VAC/50-60 Hz, Universal Input
Power Supply

US-48-500W

US-48-750W

| AC/DC, Internal, 500W DC

AC/DC, Internal, 750W DC

Rack-Mount| Yes, 1U High
ESD/EMP Protection| Air: ± 24 kV, Contact: ± 24 kV
Shock and Vibration| ETSI300-019-1.4 Standard
LEDs Per Port

RJ45 Data Ports

SFP+/SFP Data Ports

| PoE, Speed/Link/Activity

Speed/Link/Activity

Interfaces
Management| (2) 1/10 Gbps SFP+ Ethernet Ports

(2) 1 Gbps SFP Ethernet Ports

(1) RJ45 Serial Port Out-of-Band, Ethernet In-Band

Operating Temperature| -5 to 40° C (23 to 104° F)
Operating Humidity| 5 to 95% Noncondensing
Certifications| CE, FCC, IC

PoE Per Port

PoE Interfaces| POE+ IEEE 802.3af/at (Pins 1, 2+; 3, 6-)
Max. PoE+ Wattage per Port by PSE| 34.2W
Voltage Range 802.3at Mode| 50-57V

Safety Notices

  1.  Read, follow and keep these instructions.
  2.  Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.
    WARNING: Failure to provide proper ventilation may cause re hazard. Keep at least 20 mm of clearance next to the ventilation holes for the adequate arrow.
    WARNING: To reduce the risk of re or electric shock, do not expose this product to rain or moisture.
    WARNING: Do not use this product in a location that can be submerged in water.
    WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1.  Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment, or pose is a hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3.  This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    b. The equipment requires the use of the ground wire as a part of the safety certification, medication or misuse can provide a shock hazard that can result in serious injury or death.
    c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    d. Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.

Limited Warranty

ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1.  This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand

| Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.
---|---

CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.

WEEE Compliance Statement (ui.com)
Ubiquiti – Compliance
Online Resources

UBIQUITI US-48-500W Network Unifi Switch -fig we

© 2020 Ubiquiti Inc. All rights reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals