CUSTOMER CARE AND SERVICE
Always use original spare parts. When contacting our Authorised Service
Centre, ensure that you have the following data available:
Model number, receipt, and serial number.
The refrigerant used in the portable air conditioners is the environmentally
friendly hydrocarbon R290. This refrigerant is odorless and compared to the
alternative refrigerant, the R290 is an ozone-free refrigerant.
Warning / Caution-Safety information. General information and tips.
Environmental information. Subject to change without notice.D
G
|
---|---
H
IJ
Operating Instructions
PRODUCT DESCRIPTION
M
N
O
WOOD’S FOR CLEAN AND HEALTHY INDOOR AIR
The brand Wood’s was born with the Wood’s family over 65 years ago in the Canadian city of Guelph, Ontario. his is where Wood’s began developing and manufacturing dehumidifiers in 1950. Since then Wood’s has helped several hundred thousand households to prevent damages from mold damp and to breathe cleaner air. Our portable air conditioners are suitable for use in most climates, where capacity is good even at different temperatures and humidity levels. They are used with good results in premises that become hot such as living rooms, offices or bedrooms. The amount of hot air that the air conditioner removes depends on the temperature, humidity level, and placement. External weather conditions may also affect the performance of it conditioner. Wood’s air conditioners are safe in operation and intended for continuous use over many years.
HOW DOES THE AIR CONDITIONING UNIT WORK?
Low pressure gives cold air The main element of the air conditioner is a coolant, which under low pressure is converted to gas. The process “creates cold”, which is transmitted inward, while keeping the warm air out. A liquid coolant is passed through an expansion valve and into a pipe where the pressure is low. The coolant evaporates and turns into a gas. The process absorbs heat from the surroundings and the pipe is cooled. A fan blows the cold air into the room. The gas is passed through a compressor, which increases the pressure and converts the gas into a liquid. In this process, heat is released, which is led to pipes on the opposite side and blown out by a fan. A thermostat shuts off the unit when the indoor air is cold enough.
1. SECURITY WARNINGS Flammable material. This appliance contains R290/
Propane a flammable refrigerant.
Refer to this manual for safety information. Read technical manual
SAFETY INFORMATION
Before the installation and use of the appliance, carefully read the supplied
instructions. The manufacturer is not responsible if an incorrect installation
and use cause injuries and damages. Always keep the instructions with the
appliance for future reference.
Children and vulnerable people safety
WARNING
Risk of injury or permanent disability. This appliance can be used by children
aged 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning the use of the appliance in a safe way
and understand the hazards involved. Do not let children play with the
appliance. Children of less than 3 years should be kept away unless
continuously supervised. Keep all packaging away from children. Cleaning and
user maintenance shall not be made by children without supervision.
General Safety
This appliance is intended to be used in households and similar applications
such as Family room, living room, staff kitchen areas in shops, offices, and
other working environments. The rating plate is located at the side or ack of
the Air Conditioner. Keep ventilation openings clear of obstruction.
Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer. The appliance shall
not be stored in a room with operating ignition sources for example open
flames, an operating gas appliance, or an operating electric heater. Do not
pierce or urn. Be aware that refrigerants may not contain an odor. Do not use
water spray and steam to clean the appliance. Clean the appliance with a moist
soft cloth. Only use neutral detergents. Do not use abrasive products,
abrasive cleaning pads, solvents, or metal objects. If the supply cord is
damaged, it must be replaced by the manufacturer, its Authorised Service
Centre, or similarly qualified persons in order to avoid a hazard.
SAFETY INSTRUCTIONS Installation WARNING
Only a qualified person must install this appliance. Remove all the packaging.
Do not install or use a damaged appliance. The appliance shall be installed,
operated, and stored in a room with a floor area larger than 12 m². obey, the
installation instruction supplied with the appliance. Always be careful when
you move the appliance because it is heavy. Always wear safety gloves. Be
aware that refrigerants may not contain an odor.
Make sure the air can circulate around the appliance. Wait at least 4 hours
before connecting the appliance to the power supply. This is to allow the oil
to flow back into the compressor. Do not install the appliance close to
radiators or other heat sources. Do not install the appliance where there is
direct sunlight.
Electrical connection
WARNING
Risk of fire and electrical shock. The appliance must be connected to a
grounded outlet. Make sure that the electrical information on the rating plate
matches with the power supply. If not, contact an electrician. Always use a
correctly installed shockproof socket. Do not use multi-plug adapters and
extension cables. Make sure to cause damage to the electrical components (e.g.
mains plug, mains cable). Contact the Authorised Service Centre or an
electrician to change the electrical components. The main cable must stay
below the level of the main plug. Connect the mains plug to the mains socket
only at the end of the installation. Make sure that here is access to the
mains plug after the installation. Do not pull the main cable to disconnect
the appliance. always pull at the mains plug.
Use
WARNING
Risk of injury, burns, electrical shock, or fire. Do not change the
specification of this appliance. Be careful not to cause damage to the
refrigerant circuit. It contains propane (R290), a natural gas with a high
level of environmental compatibility. This gas is flammable. If damage occurs
to the refrigerant circuit, make sure that there are no flames and sources of
ignition in the room. Ventilate the room. Do not put flammable products or
items that are wet with flammable products near or on the appliance.
Disposal
WARNING
Risk of injury. Disconnect the appliance from the main supply. Cut off the
main cable and discard it. The refrigerant circuit of this appliance is ozone-
friendly. Contact your municipal authority for information on how to discard
the appliance correctly. Do not cause damage to the part of the cooling unit
that is near the heat exchanger.
References