Woods WCD2 Pro Professional Dehumidifier Instruction Manual

June 6, 2024
Woods

Woods - Logo Made in Sweden

**DEHUMIDIFIER

**

OPERATING INSTRUCTIONS FOR:
WCD2 Pro WCD3 Pro WCD4 Pro
Operating Instructions

Thank you very much for choosing this Pro dehumidifier from Wood’s. Please read this instruction manual carefully before installing and using this appliance. Please keep this instruction manual in a safe place for future reference.

Woods WCD2 Pro Professional Dehumidifier - Cover

Visit warranty-woods.com for more information and updated instruction manuals. You will find information about registering your product and regular news. Depending on the product line, Wood’s provides different type of warranty. More to discover online woods.se.

TECHNICAL DRAWINGS

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
1FOLDING HANDLE

| Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
2| Woods WCD2 Pro
Professional Dehumidifier - TECHNICAL DRAWINGS 3
---|---|---

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
4STACKING

| Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
6|

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
5SECURE STACKING

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
7TRANSPORT OF THE DEHUMIDIFIER|

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
8HOUR COUNTER

| Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
9

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
10WASHABLE FILTER

|

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
11WHEELS

|

Woods WCD2 Pro Professional Dehumidifier - TECHNICAL DRAWINGS
12SECURING THE WATER TANK

Flammable material. This appliance contains R290/Propane a flammable refrigerant.
Refer operators manual.
Read technical manual
Read operators manual.

SAFETY INFORMATION

Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference.

Children and vulnerable people safety

WARNING
Risk of injury or permanent disability. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Do not let children play with the appliance.
Children of less than 3 years should be kept away unless continuously supervised.

Keep all packaging away from children. Cleaning and user maintenance shall not be made by children without supervision.

General Safety

This appliance is intended for use in large and open spaces. For the building, and warehouses, in shops, offices and other working environments. The rating plate is located behind the water tank of the dehumidifier. Keep ventilation openings clear of obstruction.
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. The appliance shall not be stored in a room where ignition sources are operating continously (open flames, working gas appliance or an operation electric heater. Do not pierce or burn. Be aware that refrigerants may not contain an odour. Do not use water spray and steam to clean the appliance. Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. If the supply cord is damaged, it must be replaced by the manufacturer, its Authorised Service Centre or similarly qualified persons in order to avoid a hazard.

SAFETY INSTRUCTIONS Installation

WARNING
Only a qualified person must install this appliance. Remove all the packaging. Do not install or use a damaged appliance. The appliance shall not be stored, operated and stored in a room with a floor area larger than 4m². Obey the installation instruction supplied with the appliance. Always be careful when you move the appliance because it is heavy. Always wear safety gloves.
Make sure the air can circulate around the appliance. The dehumidifier should be transported according to the instructions (see separate info). If the dehumidifier has been transported according to the instructions, the dehumidifier can be started immediately after transport. If the dehumidifier has not been transported according to instructions wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back in the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance where there is direct sunlight.

Electrical connection

WARNING
Risk of fire and electrical shock. The appliance must be connected to a grounded outlet. Make sure that the electrical information on the rating plate agrees with the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket. Do not use multi-plug adapters and extension cables. Make sure not to cause damage to the electrical components (e.g. mains plug, mains cable). Contact the Authorised Service Centre or an electrician to change the electrical components. The mains cable must stay below the level of the mains plug. Connect the mains plug to the mains socket only at the end of the installation. Make sure that there is access to the mains plug after the installation. Do not pull the mains cable to disconnect the appliance. Always pull at the mains plug.

Use

WARNING
Risk of injury, burns, electrical shock or fire. Do not change the specification of this appliance.

Be careful not to cause damage to the refrigerant circuit. It contains propane (R290), a natural gas with a high level of environmental compatibility. This gas is flammable.
If damage occurs to the refrigerant circuit, make sure that there are no flames and sources of ignition in the room. Ventilate the room. Do not put flammable products or items that are wet with flammable products near or on the appliance.

Disposal

WARNING
Risk of injury. Disconnect the appliance from the mains supply. Cut off the mains cable and discard it. The refrigerant circuit of this appliance is ozone-friendly. Contact your municipal authority for information on how to discard the appliance correctly. Do not cause damage to the part of the cooling unit that is near the heat exchanger.

TECHNICAL DATA

| WCD2 Pro| WCD3 Pro| WCD4 Pro
---|---|---|---
Max. working area| 140m2| 190 m2| 230 m2
Air flow step 1| 190m3/h| 197m3/h| 129m3/h
Air flow step 2| 336m3/hour| 336m3/hour| 296e/hour
Dehumidifying at 20°C and 70% r.h.| 11 1/24h| 121/24h| 251/24h
Dehumidifying at 30°C and 80% r.h.| 19I/24h| 25,5l/24h| 411/24h
Power at 20’C and 70% r.h.| 320 W| 420 W| 500 W
Power consumption at 20°C and 70% r.h.| 7,3 kWh/24h| 9,3kWh/24| 12kWh/24
Tank volume| 11,4 litres| 11,4 litres| 11,4 litres
Refrigerant| R290| R290| R290
Charge| 110 g| 120 g| 150 g
Voltage| 230V| 230V| 230V
Frequency| 50Hz| 50Hz| 50Hz
Current| 2,2 A| 3 A| 3,3 A
IP Code| IPX1| IPX1| IPX1
Dimensions in mm, L x Bx H| 508x464x595| 508x464x595| 508x464x595

*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as temperature, ventilation and humidity.

PROBLEM SOLUTION
Dehumidifier does not start – Check that dehumidifier is connected to

electricity and that fuse has not gone
– If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier.
Check that float is free
– Check that hygrostat is working. Dehumidifier should start when hygrostat is in Maximum position
Does not dehumidify| – Check that fan is spinning
– Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand
20-30cm from wall
– Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehumidifying cycle, when the compression stops. Wait initially for about 35 minutes.
– Check that a thick coating of ice has not formed on the cooling coils.
High noise level| – Increase distance behveen dehumidifier and surrounding surfaces
– Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils
Ice formation on cooling coils| – Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing passage of air through machine
No water enters reservoir| – Check for obstruction to drip-tray above water reservoir
Does not tum off when water reservoir is full
The Led is flashing in green| – It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping
– To low temperature- increase room temperature.
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier

*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as temperature, ventilation and humidity.

DESCRIPTION OF TECHNICAL DRAWINGS

FOLDING HANDLE

  1. Important! Make sure that the handle is secured in its desired position with the locking pins.

  2. The locks for the handles are attached to the housing to avoid being lost.
    STACKING

  3. There are four feet under the machine to allow stacking. The machines can be stacked up to save storage space when not in use.

  4. Ensure that the feet under the machine are clean before stacking to avoid scratches.

  5. The handle must be in a folded down position when stacking.
    SECURE STACKING

  6. NOTE: Do not stack more than 2 machines high. Secure the machines to ensure they do not fall or move.
    TRANSPORT OF THE DEHUMIDIFIER

  7. important The dehumidifier should be transported according to the above instructions. In such case, the dehumidifier can be started immediately after transport. If the dehumidifier has not been transported according to the above instructions allow at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back in the compressor.
    HOUR COUNTER

  8. The integrated hour counter measures how many hours the dehumidifier has been used.

  9. Please note the hour counter cannot be reset.
    WASHABLE FILTER

  10. Washable permanent filter
    • Keep the filter clean and always use a clean air filter. Do not allow any material to clog the filter, as this may cause the dehumidifier to overheat.
    • Never use the dehumidifier without a filter. Always check, and if necessary clean the filter before switching the dehumidifier on.
    • Do not allow oil, grease, or other external material to be drawn into the dehumidifier.
    • Do not clean the dehumidifier with abrasive solvents.
    • Ensure that the filter sits in the frame fully when installing it.
    WHEELS

  11. Rubber wheels with polypropylene rim: 200mm diameter 200, 50 mm width and 20 mm slide bearing. Support up to 100kg. Make sure the wheels are clean before moving the machine on sensitive floors
    SECURING THE WATER TANK

  12. Ensure that the water tank is secured with the locking strap before moving the machine.

WOOD’S, THE WORLD’S LEADING DEHUMIDIFIERS

Wood’s dehumidifier products have been known as market leaders for many years. Their dehumidifiers are suitable for use in the most demanding climates, where dehumidifying capacity is good even at lower temperatures and humidity levels. They are used with good results in premises that become damp such as large open spaces, storage rooms and buildings.
The amount of humidity that the dehumidifier removes depends on temperature, humidity level and placement. External weather conditions may also affect the performance of the dehumidifier. In cold weather the absolute humidity decreases and thus the extraction of humidity from the air by the dehumidifier is reduced. (The relative humidity might still be on a high level.) The dehumidifier is suitable for use in the temperature range +2°C to +35°C.
Wood’s dehumidifiers are safe in operation and intended for continuous use over many years.

EXCESSIVE AIR HUMIDITY ­ A DANGER

Condensation occurs when water vapour in the air comes into contact with a cold surface such as cold window or wall. When water vapour is cooled down, condensation occurs, and water-drops are formed. In high air humidity, the air may get musty and mould might get formed, causing damage to a house and its furnishings. This environment may even cause illness for the residents. Mites and spiders also thrive in damp environments. A dehumidifier with high performance creates a good, healthy humidity level. For greatest efficiency, the doors and windows of rooms that are being dehumidified should be kept closed. Removes odours, dries wood, and removes moisture from sportswear outdoors equipment.

A dehumidifier may be used for buildings and in large and open spaces, If the humidifier is kept in colder environments, you should study the Hints at the end of the manual.

PLACEMENT OF DEHUMIDIFIER

Wood’s dehumidifiers are easy to move around, all you need to have is a power source for 220/240V, but bear in mind the following:

  • The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight, as it will reduce performance.
  • It is beneficial to use a radiator or heating fan to keep the temperature above +2°C.
  • The dehumidifier should stand at least 25cm from a wall or other obstruction, for maximum air flow.
  • Ideal is to put it in the center of the room/area.

NOTE: When placed in a shower or bathing area, the dehumidifier should be fixed in place. It is compulsory to check and respect your local bathroom electrical regulations before use.

USING THE DEHUMIDIFIER

The dehumidifier should be transported according to the instructions. In the event of improper positioning during transport, oil may flow out of the compressor and into the closed pipe system. In such a case, let the dehumidifier stand for a 4 hours before being used. It is very important that the oil runs back into the compressor, otherwise the dehumidifier may be seriously damaged.

  1. Check that the water reservoir is correctly placed and the float moves freely in the reservoir. See the section on the Float.
  2. Connect the dehumidifier to an grounded power source.
  3. Select fan speed.
  4. Set the desired humidity level by means of the humidity control. See the section on the humidity control.

NOTE: When the dehumidifier is turned off, it will take 5 minutes before the dehumidifier is restarted, the built-in automatic functions are deactivated, during this period.

THE FLOAT

The float consists of a white plastic cylinder which hangs on two arms. The float rests on the surface, so it is lifted when the water level rises. When the float reaches a certain height, the dehumidifier responds to this and shuts down automatically to prevent flooding of the tank.

When you have emptied the water reservoir and are to replace it in the dehumidifier follow these steps:

  1. Push the water reservoir in until it touches the float.
  2. Raise the forward edge of the water reservoir from below so that the whole water reservoir is slightly slanted.
  3. Push the water reservoir home. The float should now be in the reservoir instead of being stuck behind it.

NOTE: It is important that the float moves freely, since its purpose is to respond to the water level and ensure that the dehumidifier is turned off when it is high. A wrongly placed float may allow the water reservoir to flood.

DRAINAGE OF WATER

The dehumidifier is fitted with a hose connection. By attaching a hose to the dehumidifier the condensed water can be drained directly away.

Using the hose:

  1. Disconnect the dehumidifier from the power source and remove the water reservoir to give access to the drip tray.
  2. Attach the hose coupling to the thread on the dehumidifier and lead the hose to a drainage outlet. Check that the hose is not above the level of the drip tray.
  3. Connect the dehumidifier to the power source.

Without hose, direct to a drain outlet:

  1. Disconnect the dehumidifier from the power source and remove the water reservoir.
  2. Place the dehumidifier directly over the drain so that the dehumidified water can drip through the hole at the base of the dehumidifier and into the drain.
  3. Connect the dehumidifier to the power source.

HUMIDITY CONTROL

Wood’s dehumidifier is fitted with a built-in humidity control, which is set to the desired level of humidity. The control registers the current level of humidity and ensures that the dehumidifier is turned on and off automatically.

How to set the humidity control:

  1. Set the humidity control knob to the maximum position.
  2. Set the fan to position II .
  3. When the desired level of humidity is reached, the hygrostat knob is turned counterclockwise until the dehumidifier is turned off.

NOTE: The ambient relative humidity is most simply measured with a Wood’s hygrometer, and the most suitable range is between 50% and 60%.

SHUTTING OFF AUTOMATICALLY

When the water reservoir is full, the dehumidifier is shut off automatically. The indicator light at the front of the dehumidifier will switch to red to show that the water reservoir should be emptied.

  1. Disconnect the dehumidifier from the power source.
  2. Empty the water reservoir.
  3. Put the empty water reservoir back and check that the float moves freely. See the section on the Float.
  4. Connect the dehumidifier to the power source.

THE AIR FILTER

The air filter at the rear of the dehumidifier ensures that the cooling coils are kept free from dust. It is important that the filter is kept clean so that air can flow freely through the dehumidifier.
Your dehumidifier is equipped with a washable filter that enhances the capacity of the dehumidifier and cleanses the air further. Please refer to the separate filter leaflet for installation and maintenance instructions.

AUTOMATIC DEFROSTING

Wood’s dehumidifiers are fitted with a control unit which ensures that the cooling coils are defrosted automatically when needed. The control shuts down the compressor, which causes the cooling of the coils to stop. The fan continues to draw the air at room temperature through the dehumidifier and thus melts the ice, and the water runs down into the reservoir. This defrosting system means that the dehumidifier works at temperatures as low as +2°C.

FAN

The fan ensures that air flows through the dehumidifier. Moist air is sucked in from the rear and goes via the cooling coil and the vaporizer to come out dry and warm at the front of the dehumidifier. Wood’s dehumidifiers are fitted with two fan speeds.

  • Position II ­ gives a high air flow with maximum dehumidifying of air.
  • Position I ­ gives a lower air flow which causes quieter operation and somewhat lower dehumidifying capacity.

**ACCESSORIES

**

The dehumidifiers in WCD-series (WCD2, WCD3 and WCD4) can be equipped with an external water pump to drain the condensate water. This is an accessory and it is sold separately.
The dehumidifiers in WCD-series (WCD2, WCD3 and WCD4) can be equipped with a F8 filter which is efficient to capture silica dust. When using a F8 filter it should be replaced regularly (when full) and not cleaned. You can contact your reseller for further usage instructions and replacement cycles. This is an accessory and it is sold separately.

CLEANING AND MAINTENANCE

Wood’s dehumidifiers require cleaning of filter, to maintain their high dehumidifying capacity.

  • The front grid can be vacuum-cleaned or cleaned with a brush.
  • The cooling coils are best cleaned with a rag and warm water-be careful
  • The fan motor is permanently lubricated and requires no maintenance.

NOTE: Always disconnect the cord before cleaning.

HINTS:

  • Sometimes it may be useful to use a frost guard or heater fan to make sure that the temperature does not fall below +2°C.
  • For maximum dehumidifying power in a room, it is recommended that the air supply from outside and from adjoining rooms is minimized ­ close doors and ventilators.
  • Put in the center of the room
  • Increase temp. for faster dehumidification ( warm air carries more water.)
  • Use frost guard if temperature falls below +2°C
  • Higher dehumidification in autumn/summer because outside air is warm and humid. (Absolute humidity is normally higher).

WHEN THE DEHUMIDIFIER REQUIRES SERVICING
If the dehumidifier requires servicing, you must first contact the retailer. Proof of purchase is required for all guarantee claims.

PRODUCT GUARANTEE

All professional machines are covered with a 1-year manufacturer guarantee from the date of purchase. The guarantee is limited to the provision of repairs, free of charge, within the specified period providing the conditions are met. The warranty is non-transferable. If your Professional machine was purchased with a retailer or supplier you must contact them to initiate a guarantee claim.
The guarantee does not cover:

  • Any repairs or replacement of components during the warranty period will not result in an extension of the warranty period.
  • The warranty will be voided if any alterations have been made, if not genuine components have been fitted or if the dehumidifier has been repaired by a third party.
  • Components subject to normal wear and tear, such as the air filter, are not covered by the warranty.
  • The warranty is only valid on presentation of the original, unaltered, and date-stamped purchase receipt.
  • The warranty does not cover damage caused by actions that deviate from those as described in the user’s manual or by neglect.
  • The warranty does not covered faults caused by dirt of third-party products.
  • The warranty does not cover accidental damage.
  • All claims for compensation, including consequential damage, will not be entertained. For product guarantee and extended guarantee options, read more at woods.se Register your product at warranty-woods.com

Recommended limits for use
Temp. WCD +2°C to +35°C
Relative humidity: 30% to 90%
Recommended humidity level: appr. 50% RH

IMPORTANT! – Wood’s dehumidifiers must be connected to an grounded power source. The power source sould be 220V-240V 50Hz

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your us device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Filter replacement
Woods WCD2 Pro Professional Dehumidifier - Filter
replacementWood’s is marketed and distributed by:
TES Scandinavia AB.
Maskingatan 2-4
441 27, Alingsås
Sweden.
woods.se
[email protected]
+46 317613610
Woods - Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Woods User Manuals

Related Manuals