Woods MDX14 Compact and Convenient Dehumidifier Instruction Manual
- June 6, 2024
- Woods
Table of Contents
- Woods MDX14 Compact and Convenient Dehumidifier
- WOOD’S ONE OF THE WORLD’S LEADING DEHUMIDIFIERS
- SECURITY WARNINGS
- SAFETY INSTRUCTIONS Installation WARNING
- USE
- SET UP DEHUMIDIFIER FOR INSTALLATION
- PRODUCT DESCRIPTION
- PLACEMENT OF DEHUMIDIFIER
- USING THE DEHUMIDIFIER
- OPERATION MANUAL
- ECO MODE
- DEHUMIDIFICATION MODE
- AIR FILTER
- DEFROSTING OPERATION
- MAINTENANCE
- HINTS
- TECHNICAL DATA
- Guarantees
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Woods MDX14 Compact and Convenient Dehumidifier
WOOD’S ONE OF THE WORLD’S LEADING DEHUMIDIFIERS
Wood’s dehumidifiers have been known as market leaders for many years. Their
dehumidifiers are suitable for use in the most demanding climates, where
dehumidifying capacity is optimal even at different temperatures and humidity
levels. Excellent results can be achieved within indoor areas that become
damp, such as basements, garages, pool rooms, attics, and summer houses.
Compared to conventional tumble dryers, Wood’s dehumidifiers do not wear out
clothes as they utilize a blow-drying effect while being energy efficient,
making them ideal for drying laundry. The amount of humidity that the
dehumidifier removes depends on
the temperature, humidity level, and placement. External weather conditions
may also affect the performance of the dehumidifier. In cold weather, the
absolute humidity decreases, thus reducing the extraction of humidity from the
air by the dehumidifier. Wood’s dehumidifiers are safe in operation and
intended for continuous use over many years.
EXCESSIVE AIR HUMIDITY – A DANGER
Condensation occurs when water vapour in the air comes into contact with a
cold surface such as a cold window or wall. When water vapour is cooled down,
condensation occurs, and water drops are formed. In high air humidity, the air
may get musty and mould might get formed, causing damage to a house and its
furnishings. This environment may even cause illness for the residents. Mites
and spiders also thrive in damp environments. A dehumidifier with high
performance creates a good, healthy humidity level. For optimal efficiency,
the doors and windows of rooms that are being dehumidified should be kept
closed. Dehumidification helps remove odours, dries wood, and removes moisture
from outdoors equipment.
SECURITY WARNINGS
SAFETY INFORMATION
Before the installation and use of the appliance, carefully read the supplied
instructions. The manufacturer is not responsible if an incorrect installation
and use causes injuries and damages. Always keep the instructions with the
appliance for future reference. Children and vulnerable people safety
WARNING
Risk of injury or permanent disability. This appliance can be used by children
aged 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning the use of the appliance in a safe way
and understand the hazards involved. Do not let children play with the
appliance. Children of less than 3 years should be kept away unless
continuously supervised. Keep all packaging away from children. Cleaning and
user maintenance shall not be made by children without supervision.
General Safety
This appliance is intended to be used in households and similar applications
such as, basements, crawl spaces; staff kitchen areas in shops, offices, and
other working environments. The rating plate is located at the back or the
side of the dehumidifier. Keep ventilation openings clear of obstruction. Do
not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer.
The appliance shall not be stored in a room with operating ignition sources
(for example; open flames, an operating gas appliance, or an operating
electric heater. Do not pierce or burn. Be aware that refrigerants may not
contain an odour. Do not use water spray and steam to clean the appliance.
Clean the appliance with a moist soft cloth. Only use neutral detergents. Do
not use abrasive products, abrasive cleaning pads, solvents, or metal objects.
If the supply cord is damaged, it must be replaced by the manufacturer, its
Authorised Service Centre, or similarly qualified persons in order to avoid a
hazard.
SAFETY INSTRUCTIONS Installation WARNING
- Only a qualified person must install this appliance.
- Remove all the packaging.
- Do not install or use a damaged appliance. The appliance shall be installed, operated, and stored in a room with a floor area larger than 2 m². Obey the installation instruction supplied with the appliance.
- Always be careful when you move the appliance because it is heavy. Always wear safety gloves.
- Make sure the air can circulate around the appliance.
- Wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back in the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance where there is direct sunlight. Electrical connection
WARNING
- Risk of fire and electrical shock. The appliance must be connected to a grounded outlet.
- Make sure that the electrical information on the rating plate matches with the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket.
- Do not use multi-plug adapters and extension cables.
- Make sure not to cause damage to the electrical components (e.g. mains plug, mains cable). Contact the Authorised Service Centre or an electrician to change the electrical components.
- The mains cable must stay below the level of the mains plug. Connect the mains plug to the mains socket only at the end of the installation.
- Make sure that there is access to the mains plug after the installation.
- Do not pull the mains cable to disconnect the appliance. Always pull at the mains plug.
USE
WARNING
- Risk of injury, burns, electrical shock or fire.
- Do not change the specification of this appliance.
- Be careful not to cause damage to the refrigerant circuit. It contains propane (R290), a natural gas with a high level of environmental compatibility. This gas is flammable.
- If damage occurs to the refrigerant circuit, make sure that there are no flames and sources of ignition in the room. Ventilate the room.
- Do not put flammable products or items that are wet with flammable products near or on the appliance.
SET UP DEHUMIDIFIER FOR INSTALLATION
BEFORE FIRST USE
Let the machine stand for 4 hours before use Selecting a Location
Important
- The dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings to the room. The effectiveness of the dehumidifier depends on the rate at which humid air enters the room.
- Place dehumidifier in a location that does not restrict airflow through the front of the unit.
- A dehumidifier operating in a room will have little or no effect in drying an adjacent enclosed storage area, such as a closet unless there is adequate circulation of air in and out of the area. lt may be necessary to install a second dehumidifier in the enclosed area for satisfactory drying.
- Ensure that the unit is placed on a stable and flat surface. If the surface is not stable there is a risk of excessive vibration and that water to leak.
- There should be a minimum of 30 cm clear around the unit.
PRODUCT DESCRIPTION
- A
1. Front shell
2. Casters
3. Top panel
-
B
- Filter
- Continuous drain port
-
C
- Water tank
-
D
- Top panel
-
E
Control panel- POWER button: Start or stop the unit
- TIMER button: Set the timer, query timer and cancel timer.
- SPEED button: Fan will run on low speed or high speed.
- UP button: Adjust the humidity or timing.
- DOWN button: Adjust the humidity or timing.
- MODE button: Fan — Eco — Dryer — Auto — Dehumidification
-
F
- Front shell
- Right shell
- Water tank
-
G
- Control panel
- Filter
- Continuous drain port
- Rear shell
- Air outlet
- Left shell
- Caster
-
H
- Keep the top panel from other objects at least 50cm.
- Keep a distance of above 30 cm between the machine and the surrounding objects or walls.
-
I
- Manual drainage
- Continuous drainage
PLACEMENT OF DEHUMIDIFIER
- The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight, as it will reduce performance.
- The ideal is to put it in the center of the room/area.
NOTE: When placed in a shower room or bathing area, the dehumidifier should be fixed in place. It is compulsory to check and respect your local bathroom electrical regulations before use.
USING THE DEHUMIDIFIER
If the dehumidifier is transported horizontally, let the dehumidifier stand for 4 hours before being used. It is very important that the oil runs back into the compressor, otherwise, the dehumidifier may be seriously damaged.
- Check that the water reservoir is correctly placed.
- Connect the dehumidifier to a grounded power source.
- Set the function or desired humidity level. See the section on the humidity control.
OPERATION MANUAL
- Power Button: This button can control the machine on and off.
- Mode Button: Press to select the desired mode. It can switch to Normal dehumidification, Eco dehumidification, Auto dehumidi-fication, Ventilation mode, and Dry clothes mode.
ECO MODE
When the unit works at ECO MODE, the default humidity level is RH60%.
- When the ambient humidity ≥ 60%, the unit will work as dehumidification, the fan speed is not adjustable.
- When the ambient humidity<60%, the unit will work as a fan and the speed is not adjustable.
- The humidity level is not adjustable.
FAN MODE
Under this mode, the compressor is not engaged. By default, the adjustable fan
speed is set to “low”, for ventilation only. The humidity level cannot be set,
but the ambient humidity level (30-90%RH) is indicated on the display panel.
DRY MODE
Under this mode, the compressor will continuously run, as will the fan at high
speed regardless of room humidity. Three minutes delay protection function of
the compressor is applicable. The fan speed and humidity level cannot be
adjusted. Ambient humidity level (30-90%RH) will be indicated on the display
panel.
AUTO MODE
When the unit works on AUTO MODE, the default humidity level is RH50%
- When the ambient humidity ≥ 70%, the unit will work as strong dehumidification, the fan speed is not adjustable.
- When 50% ≤ the ambient humidity<70%, the unit will work as weak dehumidification, the fan speed is not adjustable.
- When the ambient humidity<50%, the unit will work as a fan in low speed with the fan speed not being adjustable.
- The ambient humidity level (30- 90%RH) will be indicated on the display panel, and the humidity is not adjustable.
DEHUMIDIFICATION MODE
The unit will work at dehumidification mode when power-on for the first time or choose by mode conversion, the fan speed is defaulted high, press UP and DOWN to adjust the setting humidity (35-85%).
-
Humidity can be set between 35%
– 85% (5% adjustment factor); humidity setting is only valid under dehumidification mode. -
Timer: You can set how long the unit will run or when it will start. You can select 1-24 hours.
-
Fan Speed: The speed key is valid only in dehumidification mode and ventilation mode.
-
Child-lock: Press both “Timer” and “Speed” to set or shut off the Child-lock function.
WATER DRAINAGE
When the water reservoir is full, the dehumidifier will shut off
automatically.
- Disconnect the dehumidifier from the power source.
- Empty the water reservoir.
- Put the empty water reservoir back and check that the float moves freely.
- Connect the dehumidifier to the power source.
Direct water drainage
Connect a water hose to the pipe on the back of the dehumidifier. Lead the
other end to a drain. Make sure that the water can be drained downwards by
gravity.
AIR FILTER
The air filter prevents dust and dirt from entering the machine, prolonging its life expectancy. The filter must be cleaned regularly.
Filter cleaning:
- Remove the filter.
- Wash it with warm water and a mild cleansing agent. Alternatively, the filter may be vacuum cleaned.
- Let the filter dry and put it back.
DEFROSTING OPERATION
The evaporator in the dehumidifier may defrost automatically if it is operated at room temperature less than 18 °C. The defrosting device may start up and operate for some time (about 8 minutes) automatically every 40 minutes or even longer. Please don’t turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation. This dehumidifier doesn’t have a cooling function. It will produce heat during the operation and can increase the room temperature from 1 to 4°C.
MAINTENANCE
- Clean the unit with a soft moist cloth. Do not use solvents or strong cleaners as this might damage the surface of the unit.
SERVICE
If the dehumidifier requires servicing, you must first contact your local
retailer.
WARRANTIES
2 years product warranty. Please note that the warranty is only valid upon the
production of the receipt.
STORAGE
Before storage of the unit, please follow these steps:
- Make sure the water tank is empty. When the unit is switched on, make sure the unit work at Ventilation mode for at least 30 minutes to remove the water inside the unit.
- Collect and bundle the power cord.
- Clean the filter.
- Store in a clean, dry environment.
HINTS
When the dehumidifier is used in extremely damp environments or when the
temperature is below +5˚C, the dehumidifier will stop working. A large amount
of ice builds up on the cooling coil. Turn off the dehumidifier and place it a
little above floor level so that the ice will melt away. Sometimes it may be
useful to use a fan heater to make sure that the temperature does not fall
below +10˚C. Even if the MDX14 works down to temperatures as low as +5°C, its
capacity will increase at higher temperatures as warm air carries more water.
The hydrostat has a margin of error of approx. +/- 5-10%. At lower
temperatures, the margin of error might increase further. Expect higher
dehumidification capacity during Autumn / Summer because the outside air is
warmer and more humid.
IMPORTANT! – Wood’s dehumidifiers must be connected to a grounded power
source. The power source should be 220V-240V 50Hz
PROBLEM | SOLUTION |
---|---|
The dehumidifier does not start | – Check that dehumidifier is connected |
to electricity and that fuse has not gone
– If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier.
Check that float is free
Does not dehumidify| – Check that the fan is spinning
– Check that air can flow freely through the dehumidifier. The top grid and air filter should be clean and the dehumidifier should stand 30cm from walls.
– Listen for sound from the compressor, but bear in mind that the dehumidifier may stop when the ambient humidity reaches the set humidity.
– Check that a thick coating of ice has not formed on the cooling coils.
High noise level| – Increase distance between the dehumidifier and surrounding surfaces
– Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils.
Does not turn off when water reservoir is full| – It is important that the
float moves freely in the water reservoir. If it does not, it will not respond
to water levels and prevent the dehumidifier from stopping
No water enters the reservoir| – Check for obstruction to drip-tray above
water reservoir
FL| – Water reservoir is full. Empty the water reservoir and put it back.
E1| – Temp-humidity sensor failure. Replace the temp-humidity sensor.
If none of the above works, you should contact your nearest retailer for
checking and a possible overhaul of a dehumidifier.
TECHNICAL DATA
TECHNICAL DATA | MDX14 |
---|---|
Max. working area | 40m2 |
Air flow step 1 | 100m3/h |
Air flow step 2 | 120m3/h |
Dehumidifying at 20˚C and 70% r.h. | 6,0 l/ 24h |
Dehumidifying at 30˚C and 80% r.h. | 10 l/24h |
Power at 20˚C and 70% r.h. | 180 W |
Power consumption at 20˚C and 70% r.h. | 4,3kWh/24 h |
Tank volume | 1,5 liters |
Refrigerant | R290 |
Charge R290 | 40 g |
Voltage | 220-240V |
Frequency | 50Hz |
Current | 1A |
IP-Code | IPX2 |
Noise level in decibels | 43dB |
Weight | 9,1 kg |
Dimensions in mm, L x Bx H | 293x183x493 |
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as temperature, ventilation, and humidity.
NOTE!
Register at www.warranty-woods.com and read
about how to get extended warranty. Please visit
www.woods.se for more information.
Recommended limits for use
- Temp. +5˚C to +35˚C
- Relative humidity: 30% to 90%
- Recommended humidity level: appr. 50% RH
Guarantees
2 years consumer warranty against production faults. Please note that the
warranty is only valid upon the production of the receipt. The warranty is
only valid if the product is used in accordance with the instructions and
security warnings expressed in this manual. The warranty does not cover any
damages caused by improper handling of the product.
NOTE: The 2 years warranty only applies for consumers and not for
commercial use of the unit.
References
- Warranty Woods
- We’re helping people and businesses control their air quality
- Warranty Woods
- We’re helping people and businesses control their air quality
- Wir helfen Menschen und Unternehmen beim Management ihrer Luftqualität
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>