Woods LD48PRO+ Maximum Capacity Clothes Dryer Dehumidifier Instructions
- June 5, 2024
- Woods
Table of Contents
- Woods LD48PRO+ Maximum Capacity Clothes Dryer Dehumidifier
- INSTRUCTIONS FOR USE”
- SAFETY INFORMATION
- GENERAL SAFETY
- SAFETY INSTRUCTIONS
- PRODUCT DESCRIPTION
- CONTROL PANEL – FUNCTION DESCRIPTION
- ALARMS / INFORMATION
- OPERATING MODES
- TECHNICAL DATA
- PROBLEM REMEDY
- WOOD’S, THE WORLD’S LEADING DEHUMIDIFIERS
- EXCESSIVE AIR HUMIDITY – A
- EMPTYING WATER CONTAINERS
- DRAIN THE WATER INTO THE SEWER
- AUTOMATIC SHUTDOWN
- CLEANING AND MAINTENANCE
- IF THE DEHUMIDIFIER REQUIRES SERVICE
- GUARANTEES
- “GUARANTEE
- SAVE YOUR RECEIPTS!
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Woods LD48PRO+ Maximum Capacity Clothes Dryer Dehumidifier
INSTRUCTIONS FOR USE”
”Flammable material. This appliance contains R290/Propane a flammable refrigerant.
Refer to the operator’s manual.
Read technical manual
Read the operator’s manual.
SAFETY INFORMATION
Before the installation and use of the appliance, carefully read the supplied
instructions. The manufacturer is not responsible if an incorrect installation
and use cause injuries and damages. Always keep the instructions with the
appliance for future reference.
CHILDREN AND VULNERABLE PEOPLE’S SAFETY
WARNING Risk of injury or permanent disability.
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Do not let children play with the appliance. Children of less than 3 years should be kept away unless continuously supervised. Keep all packaging away from children. Cleaning and user maintenance shall not be made by children without supervision.
GENERAL SAFETY
This appliance is intended to be used in household and similar applications
such as – basements, crawl spaces; staff kitchen areas in shops, offices, and
other working environments. The rating plate is located behind the water tank
of the dehumidifier. Keep ventilation openings clear of obstruction.
Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer. The appliance shall
not be stored in a room where ignition sources are operating continuously
(open flames, working gas appliance, operation electric heater, etc). Do not
pierce or burn. Be aware that refrigerants may not have an odor. Do not use
water spray and steam to clean the appliance. Clean the appliance with a moist
soft cloth. Only use neutral detergents. Do not use abrasive products,
abrasive cleaning pads, solvents, or metal objects. If the power cord is
damaged, it must be replaced by the manufacturer, its authorized Service
Centre, or similarly qualified persons in order to avoid a hazard.
SAFETY INSTRUCTIONS
WARNING Only a qualified person can install this appliance.
Remove all packaging material. Do not install or use a damaged appliance. The
appliance shall be installed, operated, and stored in a room with a floor area
larger than 4m². Strictly follow the installation instruction supplied with
the appliance. Always be careful when you move the appliance because it is
heavy. Always wear safety gloves. Make sure the air can circulate around the
appliance. Wait at least 4 hours before connecting the appliance to the power
outlet. This is to allow the oil to flow back into the compressor. Do not
install the appliance close to radiators or other heat sources. Do not install
the appliance in direct sunlight.
ELECTRICAL CONNECTION
WARNING Risk of fire and electrical shock.
The appliance must be connected to a grounded outlet. Make sure that the electrical information on the rating label is in accordance with the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket. Do not use multi-plug adapters and extension cables. Make sure not to cause damage to the electrical components (e.g. plug, cable). contact the authorized Service Centre or an electrician to change the electrical components. The cable must stay below the level of the plug. Connect the plug to the power socket only at the end of the installation. Make sure that there is access to the plug after the installation. Do not pull the power cable to disconnect the appliance. Always unplug the power cable from the plug only.
USE
WARNING Risk of injury, burns, electrical shock, or fire.
Do not change the specification of this appliance. Be careful not to cause
damage to the refrigerant circuit. It contains propane (R290), a natural gas
with a high level of environmental compatibility. This gas is flammable. If
damage occurs to the refrigerant circuit, make sure that there are no flames
and sources of ignition in the room. Ventilate the room. Do not put flammable
products or items that are wet with flammable products near or on the
appliance.
DISPOSAL
WARNING Risk of injury.
Disconnect the appliance from the main supply. Cut off the main cable and discard it. The refrigerant circuit of this appliance is ozone-friendly. Contact your local authority for information on how to discard the appliance correctly. Do not cause damage to the part of the cooling unit that is near the heat exchanger.”
PRODUCT DESCRIPTION
- Control panel
- Draught valve to open/close/aim the air stream
- Air filter
- Water container
- Change of air filter”
CONTROL PANEL – FUNCTION DESCRIPTION
Dehumidifiers in the LD series are equipped with an intuitive control panel
for simple and convenient use. Note that the control panel powers down to idle
mode 20 seconds after connection of mains voltage or after the last input and
is revived by touching the area where the function keys are located. All
keystrokes are confirmed with a beep
FUNCTION KEYS
-
On/OFF- Switches the dehumidifier on and off. In off mode, the energy consumption equals 0.5 W.
-
Setting of the desired humidity – Only active in program modes “Normal” and
“Fan”. Desired humidity can be set between 35 – 75% in steps of 1 percentage point. The set value is first displayed fixed and then flashing before the actual value reappears. -
Mode selection – Selection of the operating program, refer to points 13. – 16. below.
-
Fan speed – The speed of the fan may in “Normal” and “Fan” mode be set at low or high speed. Switching between the speeds takes place with a few seconds delay.
ALARMS / INFORMATION
- Defrost – If necessary, the cooling circuit is defrosted automatically, whereby the compressor is switched off and only the fan is in operation. The symbol goes out when the dehumidification process is restarted.
- Too high ambient temperature – If the ambient temperature exceeds 35 ° C the dehumidification process shuts off and resumes automatically when the ambient temperature falls below 35 °C. The symbol is lit as long as the temperature is 35 ° C or higher.
- Low room temperature – if the ambient temperature falls below2 ° C the dehumidification process shuts off and resumes automatically when the ambient temperature rises above 2 °C. The symbol is lit as long as the temperature is 2 ° C or lower.
- Condensate tank full – When the tank is full an audible signal is activated for 20 seconds and the symbol is lit. When the water tank is emptied and repositioned, the reset is reset to the operating program automatically. Make sure that the float hangs freely in the tank.
- Room temperature – Displays the detected ambient temperature.
- Fan speed – Fan and dashes indicate high speed and only the fan indicates low speed.
- Relative humidity – Shows current and desired target values. The latter is in connection with target value setting.
- WiFi – Indicates when WiFi is connected. Applies only to models equipped with this feature.
OPERATING MODES
-
Fan mode – Used if continuous air circulation is desired. The fan speed and target value for humidity can be set. When the set target value is reached, only the compressor is switched off to restart again if the humidity rises.
-
Comfort mode (EASY) – The dehumidifier aims for 50% relative humidity with the fan set to low speed. When the target value is reached, the compressor and fan shut off and restart if the humidity rises above 50%.
-
Laundry drying mode (LAUNDRY) – The dehumidification process is in operation with the fan at high fan speed until it
is turned off manually or the mode is changed. -
Normal Mode (NORMAL) – Used to manually set the target value for humidity and fan speed. When the set target value is reached, the compressor and fan shut off and restart if the humidity rises above the target value.
-
Lock function – Used to prevent settings unintentionally being changed. The lock function is operating the FAN and MODE keys simultaneously for 3 seconds. Disabling the lock function is done in the same way.”
TECHNICAL DATA
Max. working area | 100 m2 | 140 m2 | 180 m2 |
---|---|---|---|
Airflow step 1 | 200 m3/h | 160 m3/h | 160 m3/h |
Airflow step 2 | 350 m3/h | 300 m3/h | 300 m3/h |
Dehumidifying at 20˚C and 70% r.h. | 7,5 L/24h | 11 L/24h | 16 L/24h |
Dehumidifying at 30˚C and 80% r.h. | 13 L/24h | 19 L/24h | 31 L/24h |
Power at 20˚C and 70% r.h. | 180 W | 285 W | 450 W |
Energy consumption at 20˚ and 70% r.h. | 4,3 kWh/24 h | 8 kWh/24 h | 9,1 |
kWh/24 h
Tank volume| 11 l| 11 l| 11 l
Refrigerant| R290| R290| R290
Refrigerant change| 99 g| 115 g| 130 g
Voltage| 230 V| 230 V| 230 V
Frequency| 50 Hz| 50 Hz| 50 Hz
Fuse| 10 A| 10 A| 10 A
IP-class| X1| X1| X1
Dimensions (L x W x H)| 460 x 345 x 575 mm| 460 x 345 x 575 mm| 460 x
345 x 575 mm
- Technical changes and improvements may occur. All values are approximate and may vary depending on external circumstances such as temperature, ventilation, and humidity
PROBLEM REMEDY
The dehumidifier does not start| • Make sure that the dehumidifier is connected to the socket and that the fuse has not blown.
• If the symbol icon is lit, check that the water tank is empty and correctly seated in the dehumidifier. Make sure the float hangs freely.
• Check that the value of the humidity in the machine’s control panel is displayed by “waking up” the panel. The dehumidifier must start within 5 minutes if this is higher than the set value.
• Unplug the power cord, wait 10 seconds and reconnect it.
---|---
The dehumidifier does not start| • Make sure the fan wheel is spinning.
• Make sure that the air can flow freely through the dehumidifier. Air emissions and air filters must be clean and the dehumidifier must be at least 20-30 cm from the wall.
• Listen if the compressor is running, but keep in mind that the dehumidifier may be defrosting cycle and then the compressor will stop. Start by waiting for about 30 minutes.
• Check that a thick layer of ice does not form on the cooling coils/slats behind the filter.
High noise level/rattling| • Increase the distance between the dehumidifier and surrounding surfaces.
• The cooling coils may make contact with each other and cause vibrations. Disconnect the dehumidifier from the electrical outlet and separate the loops
No condensate water collected| • Check that no dirt etc. is deposited on the drip tray underneath the cooling coils, clean if necessary.
• Check that the temperature is above 2 ° C or below 35 ° C.
Does not shut off when the water tank is full.| • It is important that the
float hangs freely in the water tank. If it does not, it does not sense the
water level is and can therefore not ensure that the dehumidifier stops
Error code E2| • If E2 is shown in the display, the humidity sensor may be
defective. Try unplugging the power cord, wait 10 seconds, and reconnect it.
If the error code persists, contact your dealer.
If you have a problem with your dehumidifier, refer to the troubleshooting
guide. If none of the above works, contact your dealer to get your
dehumidifier serviced.”
WOOD’S, THE WORLD’S LEADING DEHUMIDIFIERS
Wood’s dehumidifier products have been known as market leaders for many years.
Our dehumidifiers are suitable for use in the most demanding climates, where
dehumidifying capacity is good even at lower temperatures and humidity levels.
They are used with good results in premises that become damp such as
basements, garages, or summer houses. They also work great when drying and
washing without wear on textiles, in pool areas, and in laundry rooms. They
are efficient and have low
energy consumption They are also excellent for drying laundry, attics, pool
rooms and. Being efficient and low in energy consumption.
The amount of moisture that the dehumidifier removes depends on temperature,
humidity level, and placement. The weather outdoors also affects dehumidifier
performance. In
cold weather the relative humidity indoors drops, thus reducing the
dehumidifier’s moisture absorption from the air. Therefore, the dehumidifier
is adapted for use in the temperature range + 2˚C to + 35˚C. Wood´s
dehumidifiers are safe and designed to operate continuously for many years.
EXCESSIVE AIR HUMIDITY – A
DANGER
Condensation occurs when the water vapor in the air comes into contact with a
cold surface such as a ceiling, window, or wall. When the water vapor cools
down condensation takes place whereby water droplets form. At high humidity,
stale air can occur and mold is formed which damages the house and its
interior. This environment can also lead to illnesses of the inhabitants when,
among other things, mites thrive in a humid environment. A dehumidifier with
high performance creates a good and healthy moisture level. To achieve the
best effect, the doors, and windows of the spaces to
be dehumidified should be kept closed. The dehumidifier removes bad odor,
dries the wood, and removes moisture from sports equipment for outdoor use,
etc. A dehumidifier can be used in basements, laundry rooms, garages,
caravans, summer cottages, and boats. If the dehumidifier is used in colder
environments, take a closer look at the hints at the end of the instructions
for use.
NOTE!
When placed in a shower or bathing area, the dehumidifier should be fixed in
place. It is mandatory to check and follow the local bathroom electrical
regulations before use.
USE WOOD’S DEHUMIDIFIERS
If the dehumidifier is transported horizontally, leave it standing upright for
4 hours before use. It is very important for the oil to flow back into the
compressor, as the dehumidifier otherwise may take serious damage. Wood’s
dehumidifiers are easy to move around when they are equipped with wheels. All
that is required is the proximity to an electrical outlet for 220-240 V, but
keep in mind the following: The dehumidifier should not be placed near
radiators or other heat sources and not exposed to direct sunlight as it
lowers performance.
- You can use a radiator or heating fan to keep the temperature above + 2˚C.
- The dehumidifier should be placed at least 25 cm away from walls and other obstructions to ensure maximum airflow.
- It is ideal to place the dehumidifier as centrally in the room/area as possible.
- Check that the water tank is in the correct position.
- Connect the dehumidifier to a grounded electrical outlet.
- Choose the desired humidity program or humidity level using the control panel. Refer to the section on function description.
NOTE!
When the dehumidifier switches off, it takes 5minutes before it restarts.
FLOAT
The float consists of a white plastic cylinder suspended by two wires hanging
in two arms. The float is buoyant and when the water level rises, the float is
lifted up. When the float has reached a certain height, the dehumidifier
detects this and turns off automatically to prevent flooding. When the water
tank is emptied it should be put back in position the following way:
EMPTYING WATER CONTAINERS
- When the water tank is full, pull it gently outwards and empty it into the drain.
- Push the water container back in until it touches the float.
- Lift the bottom edge of the water tank to incline the water tank slightly.
- Push the water tank at the last distance. The float should now have ended up in the water tank, instead of being clamped behind it.
NOTE!
It is important that the float hangs freely because its purpose is to detect
the water level in the tank and ensure that the dehumidifier switches off when
the level is high. An incorrectly positioned float can cause the water tank to
overflow.
DRAIN THE WATER INTO THE SEWER
- Disconnect the dehumidifier from the electrical outlet and remove the water tank to access the threaded connection underneath the drip tray.
- Attach the hose coupling to the threaded connector and lead the hose to the drain. Ensure that the hose is positioned lower than the drip tray.
- Insert the dehumidifier plug into the socket.
- Without hose and directly over the drain:
- Place the dehumidifier directly over the drain so that the condensed water can drip through the hole in the bottom of the dehumidifier and into the drain.
AUTOMATIC SHUTDOWN
When the water tank is full, the dehumidifier shuts off automatically, signaling that the water tank must be emptied before you can use the dehumidifier again. Refer to the function description.
- Disconnect the dehumidifier from the electrical outlet.
- Empty the water tank.
- Replace the emptied water tank and make sure the float hangs free, refer to the Float section.
- Connect the dehumidifier to the electrical outlet. The dehumidifier restarts in the same mode as when disconnected.
AIR FILTER
The air filter on the back of the dehumidifier ensures that the cooling coils
are kept free of dust. It is important that the filter is clean so that the
air can flow freely through the dehumidifier. The filter should therefore be
replaced when needed.
The dehumidifier is equipped with an SMF filter which improves the capacity of
the dehumidifier at the same time as it further purifies the air. Refer to
instructions for changing the air filter. We recommend at least one filter
change per year. To follow the warranty program Register your dehumidifier at
warranty-woods.com
AUTOMATIC DEFROST
Wood’s dehumidifiers are equipped with a control system ensuring that the
cooling coils are defrosted if necessary. The control system switches off the
compressor, which causes the cooling of the loops to stop. The fan continues
to draw the room temperature air through the dehumidifier and thus the ice
melts and the water flows down into the water tank. Note that this control
system allows the dehumidifier to operate at temperatures as low as + 2˚C”
FAN
The fan ensures that air flows through the dehumidifier. Moist air is sucked
in from
the back and through the evaporator and condenser and released dry on the top
of the dehumidifier.
CLEANING AND MAINTENANCE
Wood dehumidifiers require cleaning and filter replacement to maintain their high dehumidification capacity.
- The air outlet can be vacuumed or cleaned with a brush. Use caution to prevent the slats from being damaged.
- The cooling coils are best cleaned with a cloth and warm water. Use caution.
- The fan motor is permanently lubricated and requires no maintenance.
NOTE!
Unplug the power cord from the electrical outlet before cleaning.
HINTS
- For maximum dehumidification capacity in a room, it is recommended that the supply of air from the outside and adjoining rooms are minimized – close doors and valves. If possible, place the dehumidifier in the middle of the room.
- Raise the temperature in the room for faster dehumidification. (Hot air can carry more water). Use a frost guard if the temperature drops below + 2 ° C
- The dehumidifier extracts more water during the summer and autumn because the outdoor air is warm and moist. (The absolute humidity is normally higher).
- Recommended limits for use:
- Temp. SW + 2˚C to + 35˚C
- Relative humidity: 30% to 90%
- Recommended moisture level c.a. 50% RH
IF THE DEHUMIDIFIER REQUIRES SERVICE
If the dehumidifier requires servicing, firstly contact the retailer. For all warranty claims, proof of purchase is required.
NOTE!
Get a 10-year warranty! Register at warranty-woods.com
Replace the SMF filter at least once a year. Visit woods.se for more
information
GUARANTEES
2-year guarantee against faults in manufacturing. Please note that the guarantee only is valid upon presentation of a purchase receipt
IMPORTANT!
Wood’s dehumidifier shall be connected to a grounded electrical outlet having
a voltage of 220V-240V 50Hz.”
“GUARANTEE
TO GET AN EXTENDED WARRANTY, FROM 2 TO 10 YEARS, PLEASE FOLLOW THESE STEPS.
- Register your dehumidifier after your purchase at warranty-woods.com
- Replace the SMF filter in your dehumidifier regularly, at least once a year. If you want, we’ll send you a reminder when a filter change is due. The reminder is, of course, free of charge. You can find filters at your local retailer, or distributor. Please visit woods.se to locate your closest Wood distributor.
NOTE!
There is no obligation to purchase filters when you register your dehumidifier
at warrantywoods.
SAVE YOUR RECEIPTS!
These will be required for any warranty claim during the period.”
References
- Warranty Woods
- We’re helping people and businesses control their air quality
- We’re helping people and businesses control their air quality
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>