Product description

  • A

    1. Handle

    2. Filter holder

    3. ON/OFF button

    4. Network connection
      Product description

    5. Fuse holder

    6. Digital display

    7. Adjustment buttons
      Product description

  • B.

    1. Connection for hose nipple
      Product description

    2. USB port

    3. Connection to supply air filter (optional extra)
      Product description

  • C.
    Digital control

    1. Digital display
    2. Forward (increase)
    3. Set (menu)
    4. Back (reduce)
      Product description
  • D.
    Wear parts

    1. Prefilter
    2. Ozone pipe
      Product description
  • E.
    Additional accessories (not included)

    1. Hose nipple with 2-metre silicone hose
    2. Ozone meter (not WOZ400)
    3. Supply air filter (not WOZ400)
    4. Cigarette lighter cable (WOZ400 only)
    5. Ventilation nozzle 400mm
      Product description
  • F.

    1. Fan
    2. Air pump
    3. High-voltage module
    4. Ozone pipe
    5. Hole for hanging up (keyhole)
      Product description Product
description Product
description Product
description

THANK YOU FOR CHOOSING THE WOOD’S AIRMASTER – AN EFFICIENT, SWEDISH

QUALITY OZONE GENERATOR

The Wood’s Airmaster is an odour control device made in Sweden, with stainless steel parts that are able to withstand harsh operating conditions year after year. This ozone device rapidly and efficiently eliminates bacteria, viruses and odours from damp, mould, refuse, waste, smoke and pets.
The Wood’s Airmaster WOZ400/500 is ideal for eliminating odours in the home, office, car, boat, caravan, refuse storage room and hygiene areas. Anywhere you’d like to restore a fresh, clean smell.
The ozone also penetrates into textiles and sits on the surface of fittings and wallpapers.
The Wood’s Airmaster WOZ2000/4000 is ideal for extreme decontamination following fire damage and water damage, and for treating exhaust air in ventilation ducts/kitchen flues.

WOOD’S FOR CLEAN, HEALTHY INDOOR AIR

Wood’s has been characterised by top quality, reliability, high capacity and minimal energy consumption for more than 60 years. Today, Wood’s is distributed to more than 19 countries from the company’s head office in Alingsås.

MEMBER OF THE EUROPEAN OZONE TRADE ASSOCIATION (EUOTA) AND CO-OWNER OF THE EUOTA OZONE DOSSIER FOR ACTIVE BIOCIDAL PRODUCTS.

This futureproofs the Wood’s Airmaster, preparing it for future legislation and biocidal products regulations.

HOW DOES AN OZONE GENERATOR WORK?

Ozon is a special kind of oxygen known as active oxygen, and it’s formed by passing electrical energy into an ozone generator. The ozone works by oxidising organic substances, thereby effectively eliminating foreign odours, bacteria and viruses. In the majority of cases, the only end products are carbon dioxide and water.
The concentration of ozone in outdoor air varies from 0.001 to 0.040 parts per million (ppm). The National Board of Occupational Safety and Health has set the threshold value to 0.1 ppm of ozone over 8 hours ofexposure when working. The gas is perceived as clean, fresh air (like after a thunderstorm) at concentrations of around 0.015-0.020 ppm. The gas starts to take on a pungent odour at 0.050 ppm, and at 0.1 ppm it may cause irritation of the eyes and throat.

IMPORTANT!

Locate and eliminate whatever is causing the odour problem before running the ozone control device, otherwise the odour will return.
Ozone is harmful when inhaled, so ozone devices must be used with care.

Wood’s Airmaster WOZ400/500

Not to be used for any length of time in areas where humans or animals are present. Brief exposure, such as in refuse storage rooms or similar, is non- hazardous.

Wood’s Airmaster WOZ2000/4000

The area must not be entered while treatment is in progress.
Read the instructions carefully before use

SAFETY WARNINGS

See these instructions for safety information.
Read the technical manual
**** Read the instructions.

SAFETY INFORMATION

Read carefully through the instructions supplied before installing and using the device.
The manufacturer accepts no liability for incorrect installation resulting in injury and damage to property. Always keep the instructions together with the device for future reference.

Safety for children and vulnerable people

WARNING
Risk of injury or permanent disability.
Do not allow children to playwith the device.
Keep all packaging out of the reach of children.
Children must not clean or maintain the device.

General safety

Ozone devices must be used with caution and not for any length of time in environments occupied by people, such as homes or offices. Brief exposure, such as in refuse storage rooms or similar, is non-hazardous (WOZ400/500).
Do not rinse the equipment with water, and do not position it anywhere where it will come into contact with water.
Observe the recommended room areas when using the device on premises occupied by people.
The power supply to the equipment must be switched off for all servicing and repair work. All use of the equipment must be in accordance with this manual. No liability is accepted for any other use.

SAFETY AND SECURITY REGULATIONS

Installation

WARNING
Remove all packaging and check that the product is not damaged. Do not use/install the product if it is damaged.

Connection to the power supply

**** WARNING
Risk of fire and electric shocks if used incorrectly.
The device must be connected to an earthed socket.
Make sure that the electrical information on the rating plate matches the power supply. If not, contact an electrician. Always use a correctly installed, shockproof socket. Never use a damaged branch socket or extension cable.
Make sure that the electrical components are not damaged (e.g. plug, mains cable). Contact the authorised service centre or an electrician if electrical components need to be replaced.
Only connect the plug to the power socket when installation is complete. Make sure that accessing the plug is easy after installation. Do not pull on the cable when disconnecting the device. Always hold onto the plug when pulling it out.

Disposal

WARNING
**** Disconnect the device from the mains.
Please use the return and collection systems to recycle your device. Get in touch with your municipality for information on how to dispose of the device correctly.

USING AND MAINTAINING YOUR OZONE DEVICE

IMPORTANT!

Locate and eliminate whatever is causing the odour problem before running the ozone control device, otherwise the odour will return.
Ozone is harmful when inhaled, so the ozone device must be used with care.
Do not use the ozone device when there are people present in the room.
For the Wood’s Airmaster WOZ400/500, brief exposure (less than 5 minutes) is non-hazardous.
For the Wood’s Airmaster WOZ2000/4000, the area must not be entered at all.

Treatment with the Wood’s Airmaster

Preparation:

Clean the room thoroughly, vacuum and wipe down all surfaces and/or repair/eliminate the problem causing the odour.

Make sure that the area is safe to treat:

Remove pets and plants. Remove valuable high-tech equipment such as laptops and valuable oil paintings. Make sure that there are no people in the room.

Ozone treatment:

Position the ozone device in the middle of the room (ideally on a slightly raised surface such as a table). Connect the mains cable supplied to the mains socket (A4). The ozone device can now be started by pressing the on-off button (A3), and you set the timer (C) to the preferred time (models with a timer).
It can take up to about 5 minutes to achieve the full effect.

Duration of treatment:

2 to 72 hours, depending on the intensity of the odour. The average treatment time is 24 hours. Ideally, start off with 4-8 hours and repeat as necessary.

After the ozone treatment:

Switch off the ozone device and open the windows. There will be ozone in the air after the treatment, it smells like chlorine. Air the rest of the room to remove the remaining ozone.
Check the room. If there are still unwanted odours in there, repeat the procedure. All affected rooms must be treated separately.

Permanent installation

The ozone device can be wall-mounted by means of a “keyhole solution” (F5) on the underside of the ozone device.
Connect the mains cable supplied to the mains socket (A4). The ozone device can now be started by pressing the on-off button (A3).

Connecting the silicone hose (E1)

The nipple and silicone hose accessories (E1) are mounted in the connecting nut (B1) and the ozone can be directed into the space to be treated such as air conditioning systems, partition walls, ventilation ducts and water treatment.

Connecting the ozone meter (E2)

The ozone meter accessory (E2) is connected to the USB port (B2) on the back.

Use

Position the ozone device in a dry place that is ventilated well, ideally high up and approx. 1.5 m above the floor. It is important to ensure that nothing prevents the air entering the fan.
Connect the mains cable supplied to the mains socket (A4).
The ozone device can now be started by pressing the on-off button (A3). The ozone device starts in operating mode, with full power (100%).
It can take up to about 5 minutes to achieve the full effect.

Starting the machine

  1. Start the ozone device. Press the switch (A3) to ON
  2. Switch off the ozone device Press the power switch (A3) to OFF
Digital control with timer

(Applicable to Wood’s Airmaster WOZ500/2000/4000) The ozone quantity/output can be varied between 0 and 100%. Timer modes: daily, interval and shut-off timer. See “Digital control” instructions on the next page for further information.

Using the silicone hose

The nipple and silicone hose accessory (E1) is mounted in the connecting nut (B1) and the ozone can be directed into the space to be treated such as car interiors, partition walls and water treatment.

Connecting to a ventilation duct

When connecting to a ventilation duct/spiral pipe, the ventilation nozzle (E5) is connected by means of a nut rivet. The ozone device is then connected with the hose nipple and silicone hose (E1).

Maintenance

NOTE! Always unplug the device before carrying out servicing/maintenance.

Replacing the prefilter

The prefilter has to be replaced every two to four months, depending on the ambient environment.

  • Undo the filter holder (A2) by hand.
  • Replace the filter with a new one.
  • Put back the filter holder (A2).
Replacing the ozone pipe

Ozone is formed when a high-voltage power supply is passed into the ozone pipe. The ozone pipe must be replaced if the ozone concentration declines or ceases entirely.

  • A. If your ozone device has four chassis screws per long side:
    1. Undo the eight screws on the long sides of the chassis.
    2. Lift the cover off the machine.
    3. Go to point C
  • B. If your ozone device has no visible chassis screws:
    1. Undo the two screws that hold the handle in place.
    2. Turn the machine upside down.
    3. Undo the four screws that hold the machine’s feet in place.
    4. Remove the chassis cover by pulling/pushing the cover forwards.
    5. Go to point C.
  • C. Replace the ozone pipe:
    1. .Carefully remove the two air hoses from the ozone pipe (F4).
    2. Undo the two cables between the high-voltage module (F3) and the ozone pipe (F4).
    3. The screws that hold the ozone pipe in position (F4) are undone from the underside.
    4. Assemble in reverse order

NOTE : The ozone pipe and prefilter are wear parts and are not covered by the warranty. All servicing other than that described here must be performed by the manufacturer or an authorised partner.

Servicing

You must contact your local dealer if your ozone device requires maintenance. Receipts must be presented for all warranty claims.

Storage instructions

Store your ozone device at room temperature between +1 °C and +35 °C.

It is important to replace the prefilter at regular intervals and to replace the ozone pipe regularly. Failing to do this may impair the capacity of the ozone device and possibly harm the device.

USING THE OZONE DEVICE

Digital control

Applicable to Wood’s Airmaster WOZ500/2000/4000

Pwr 100%

TimerOff

| Normal operating mode

Use the fo r w a r d (C2) and b ac k (C4) buttons to set ozone production to the preferred level, 1-100%. The timer is switched off.

---|---
Menu| Menu

Press set (C3) to access the menu. Then use the forward button (C2) to scroll until you arrive at the function you want to change.

(You can always leave the menu by holding down the set button.)

Timer Settings| Timer

Press set (C3), the set timer mode is displayed. Press set (C3), again, the text starts to flash. Use the forward button (C2) to scroll until you find the preferred timer function. Press set (C3) to select a function.

---|---
Mode Off| Timer off (factory default)

Mode Once

| Shut-off timer

The Wood’s Airmaster operates for the preferred time and then shuts off.

Press forward (C2), “Set Timer” appears in the display. Press set (C3), the text flashes, set the preferred time by pressing forward (C2) / back (C4) (e.g. 15 min 00:15). Press set (C3) to confirm the time (the timer stops flashing). Hold down set (C3) start the timer and leave the menu. “TimedOut” is displayed when the timer has reached the end. Hold down forward (C2) and back (C4) at the same time to restart the timer.

Set the time in the following timer modes in the same way as described in Shut-off timer.

Mode Interval

| Interval timer

The Wood’s Airmaster switches between operating mode and shutdown mode at set times.

First, set the operating time: “Step on”. Press forward (C4). Then set the shut-down time: “Step off”.

---|---

Mode Daytimer

| Daily timer

The Wood’s Airmaster operates according to set times of day. NOTE: Set the clock first! (see Clock)

Set the “on” time 1: “Step on 1”. Press forward (C2), set “off” time 1: “Step off 1”. Set “on” time 2: “Step on 2”. Press forward (C2), set “off” time 2: “Step off 2”.

Set “on” time 3: “Step on 3”. Press forward (C2), set “off” time 3: “Step off 3”.

If a mode (e.g. 3) is left blank, i.e. 00:00, that mode is disabled.

SetClock

00:00

| Clock

This is where you set the clock used by the daily timer.

Press set (C3): the digits flash. Set the required time using forward (C2) and back (C4). Press set to confirm your setting. (24-hour backup in the event of a power outage)

---|---

B light On

| Backlight

The display backlight can be switched on or off.

ExtInput settings

| Connection for external device s (USB)

The input for external devices (e.g. ozone meter) can be enabled or disabled. eller på.

Operating mode can be selected: Ozone Control – A connected ozone meter can control the ozone generator to maintain a constant ozone concentration. Ozone Alarm – If a connected ozone meter discovers a leak, the machine shuts down and alerts the operator.

Factory reset

| Factory default

Restores the device to the factory defaults. NOTE: All settings will be deleted.

KEYS LOCKED

| | Key lock

The buttons are locked by holding down set (C3) and forward (C2) at the same time until “KEYS LOCKED” appears in the display. The buttons are unlocked in the same way.

---|---|---

Troubleshooting

PROBLEM CAUSE REMEDY

__

__

The device does not switch on and the power switch does not light up.

| Power supply problem.| Connect the device to a functioning power socket and switch it on.
The fuse is broken (WOZ3000/6000).| Replace the fuse.
__

The power adapter is broken (not WOZ400).

| Try a different power adapter (making sure that the adapter is to the correct specification).
The device is operating but not producing ozone.| The ozone pipe has reached the end of its life or is broken.| __

Replace the ozone pipe.

Loud fan noise.| The prefilter is dirty/clogged.| Replace the filter.
__

The machine is behaving strangely.

| __

The software has hanged.

| __

Perform a factory reset..

__

The machine settings (e.g. timer) are incorrect

| __

The machine has been set accidentally.

Contact your local dealer after you have worked through the above troubleshooting list or if your project requires a service.

Warranties

2- year factory warranty covering workmanship. Please note, the warranty is valid only on presentation of a receipt. The warranty is valid only if the product is used in accordance with the instructions and safety warnings in this manual. The warranty does not cover damage caused by incorrect use of the product.

CUSTOMER SERVICE

Always use original parts.
Make sure you have the following to hand when you contact our customer service team: Model designation, receipt and serial number

NOTE :
Register your product at www.warrantywoods.com to benefit from the special Wood’s offers available for your product.
Take a look at www.woods.se for more information.

Note that all information, safety instructions and technical data in this manual may be amended.

TECHNICAL DATA

| Airmaster WOZ400| Airmaster WOZ500| Airmaster WOZ2000| Airmaster WOZ4000
---|---|---|---|---
Ozon production| 500 mg/hour| 0–500 mg/hour| 0–2000 mg/hour| 0–4000 mg/hour
Fan capacity| 116 m3/hour| 116 m3/hour| 116 m3/hour| 116 m3/hour
Technology| Ozone pipe (quartz glass)| Ozone pipe (quartz glass)| Ozone pipe (quartz glass)| Ozone pipe (quartz glass)
Timer| –| Yes| Yes| Yes
Hose coupling| Yes| Yes| Yes| Yes
USB port| –| Yes| Yes| Yes

Energy consumption

| 20 W/12 V DC

(100-240 V mains adapter supplied)

|

20 W/100-230 V

|

45 W/100-230 V

|

85 W/100-230 V

Temperature range| +1 °C – +35°C| +1 °C – +35°C| +1 °C – +35°C| +1 °C – +35°C
Dimensions (LxWxH)| 270x180x160 mm| 270x180x160 mm| 270x180x160 mm| 270x180x160 mm
Fuse parameter| –| 630mAT 250v| 630mAT 250v| 630mAT 250v
Weight| 2.1 kg| 2.1 kg| 3.0 kg| 3.2 kg
Finish| Stainless steel| Stainless steel| Stainless steel| Stainless steel

Extra accessories

|

Hose nipple, silicone hose, cigarette lighter cable

|

Hose nipple, silicone hose, ozone meter

|

Hose nipple, silicone hose, ozone meter, ventilation filter

|

Hose nipple, silicone hose, ozone meter, ventilation filter

Wear parts

| Prefilter Ozone pipe| Prefilter Ozone pipe| Prefilter Ozone pipe| Prefilter Ozone pipe

Technical modifications and improvements may be made. All values are approximate and may vary depending on external circumstances such as temperature and humidity.

**** This label means that this product must not be disposed of with household waste anywhere in the EU. Please recycle this product responsibly to promote sustainable reuse of resources and prevent damage to the environment or human health as a consequence of uncontrolled waste disposal. To recycle your device, please use the return and collection systems contact the dealer where you purchased your product. They can submit this product for environmentally safe recycling.

Wood’s is marketed and distributed by:
Woods TES Sweden AB.
Maskingatan 2-4
441 27, Alingsås
Sweden.
woods.se
info@woods.se
+46 317613610

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals