SDC Z7200 Electric Cylindrical Lock Instruction Manual
FOR USE ON DOORS 1-3/8” ~ 2″ (35mm ~ 51mm) THICK
TOOLS REQUIRED FOR NEW INSTALLATION:
- 1 philips head screwdriver
- 1 2-1/8” (54MM) hole saw
- 1 1″ (25.4mm) drill bit
- 1 5/16” (8mm) drill bit
- 1 chisel 1 file
OPTIONAL:
DOOR CORE DRILLING GUIDE #7000-DG & CORING DRILL BIT #7000-DB
1. MARK DOOR
2. DRILL HOLES
3. INSTALL LATCH
a. Insert latch in hole and keep it parallel to door face. Mark outline and
remove latch
b. Chisel 1/8” (3mm) deep or until faceplate is flush with door edge.
c. Insert latch and tighten screws.
NOTE: LATCH BOLT BEVEL MUST FACE TOWARDS CLOSING DIRECTION.
4. INSTALL STRIKE
a. Close door to mark horizontal line of strike.
b. Measure one half of door thickness from door stop to mark vertical center
line of strike. Drill 1″ (25.4mm) hole, 1/2” (12.7mm) deep at intersection of
horizontal and vertical center lines.
c. Cut out jamb 3/32” (2.4mm) deep or until strike is flush with jamb. Tighten
screws securely.
5. REMOVE INSIDE TRIM
6. ADJUST DOOR THICKNESS
7. INSTALL OUTSIDE LEVER ASSEMBLY
Install outside lever assembly on the door. Make sure tail of latch is engaging with retractor correctly as illustrated. Refer to wire diagram on last page for wiring.
8. INSTALL INSIDE MOUNTING PLATE AND ROSE
9. INSTALL LEVER
a. Depress lever catch with tool provided. Push inside lever on completely until catch engages in lever. Confirm lever is secured.
LAYOUT
DO NOT USE AS A PHYSICAL TEMPLATE. THIS LAYOUT IS INTENDED AS A DIMENSIONAL REFERENCE ONLY. USE THE TEMPLATE PACKAGED WITH THE LOCK.
WIRE DIAGRAM
Using the PR-7200 limits the power consumption, reduces operating temperature, and suppresses inductive kickback. (The PR-7200 is only supplied with the Fail-Safe models.)
LATCH STATUS MECHANICAL SWITCH SPDT 3A @ 30VDC
LATCH STATUS
COM = WHT/RED
N/C = ORG/RED
N/O = YEL/RED
*Both options cant be used simultaneously.
REQUEST-TO-EXIT MAGNETIC SENSOR
200mA @ 30VAC (RESISTIVE)
REX
COM = GREY
N/C = YELLOW
N/O = ORANGE
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>