SDC Z7200 Electric Cylindrical Lock Instruction Manual

June 6, 2024
SDC

SDC Z7200 Electric Cylindrical Lock Instruction Manual

SDC Z7200 Electric Cylindrical Lock

FOR USE ON DOORS 1-3/8” ~ 2″ (35mm ~ 51mm) THICK

TOOLS REQUIRED FOR NEW INSTALLATION:

  • 1 philips head screwdriver
  • 1 2-1/8” (54MM) hole saw
  • 1 1″ (25.4mm) drill bit
  • 1 5/16” (8mm) drill bit
  • 1 chisel 1 file

OPTIONAL:
DOOR CORE DRILLING GUIDE #7000-DG & CORING DRILL BIT #7000-DB

FIG 1 Overview

1. MARK DOOR

FIG 2 MARK DOOR

2. DRILL HOLES

FIG 3 DRILL HOLES

3. INSTALL LATCH

a. Insert latch in hole and keep it parallel to door face. Mark outline and remove latch
b. Chisel 1/8” (3mm) deep or until faceplate is flush with door edge.
c. Insert latch and tighten screws.
NOTE: LATCH BOLT BEVEL MUST FACE TOWARDS CLOSING DIRECTION.

FIG 4 INSTALL LATCH

4. INSTALL STRIKE

a. Close door to mark horizontal line of strike.
b. Measure one half of door thickness from door stop to mark vertical center line of strike. Drill 1″ (25.4mm) hole, 1/2” (12.7mm) deep at intersection of horizontal and vertical center lines.
c. Cut out jamb 3/32” (2.4mm) deep or until strike is flush with jamb. Tighten screws securely.

FIG 5 INSTALL STRIKE

5. REMOVE INSIDE TRIM

FIG 6 REMOVE INSIDE TRIM

6. ADJUST DOOR THICKNESS

FIG 7 ADJUST DOOR THICKNESS

7. INSTALL OUTSIDE LEVER ASSEMBLY

Install outside lever assembly on the door. Make sure tail of latch is engaging with retractor correctly as illustrated. Refer to wire diagram on last page for wiring.

FIG 8 INSTALL OUTSIDE LEVER ASSEMBLY

8. INSTALL INSIDE MOUNTING PLATE AND ROSE

FIG 9 INSTALL INSIDE MOUNTING PLATE AND ROSE

9. INSTALL LEVER

a. Depress lever catch with tool provided. Push inside lever on completely until catch engages in lever. Confirm lever is secured.

FIG 10 INSTALL LEVER

LAYOUT

DO NOT USE AS A PHYSICAL TEMPLATE. THIS LAYOUT IS INTENDED AS A DIMENSIONAL REFERENCE ONLY. USE THE TEMPLATE PACKAGED WITH THE LOCK.

FIG 11 LAYOUT

WIRE DIAGRAM

FIG 12 WIRE DIAGRAM

Using the PR-7200 limits the power consumption, reduces operating temperature, and suppresses inductive kickback. (The PR-7200 is only supplied with the Fail-Safe models.)

LATCH STATUS MECHANICAL SWITCH SPDT 3A @ 30VDC

LATCH STATUS

COM = WHT/RED
N/C = ORG/RED
N/O = YEL/RED

*Both options cant be used simultaneously.

REQUEST-TO-EXIT MAGNETIC SENSOR
200mA @ 30VAC (RESISTIVE)

REX

COM = GREY
N/C = YELLOW
N/O = ORANGE

Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM

[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals