Introduction
This is a compact UPS designed for power-saving bulbs. Its portable size features easy installation and high movability. It’s the perfect choice for diverse applications from indoor to outdoor events or activities such as camping and night markets. The on-box lamp holder can be used for directly plugging in a CFL bulb with a full range of 360-degree lighting. Besides, it can accept a wide input voltage range. It’s perfect to use in unstable power areas. It is very easy to install at home, office or carry outside.
Product Overview
Front View:
1. Line mode/Charging mode indicator – Green LED | 6. Handle |
---|---|
2. Battery mode indicator – Yellow LED | 4. Power Switch |
3. Alarm indicator – Red LED | 5. Lamp holder |
(All status indicators, please check LED Indicators section for the details)
Back View:
1. AC input | 3. Power switch for lamp holder |
---|---|
2. Input Fuse | 4. Output receptacles |
Important Safety Warning
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any external object to enter the UPS.
CAUTION! In the event of an emergency, press the OFF button and
disconnect the power cord from the AC power supply to properly disable the
UPS.
CAUTION! This unit contains more than one live circuit (batteries & AC
line). Power may be present at more than one source. To reduce the risk of
electrical shock, disconnect both AC and DC power from the unit before
attempting any maintenance or replacement inside of the unit. Turning off the
unit will not reduce this risk.
CAUTION! Servicing of batteries should only be performed or supervised by
personnel knowledgeable of batteries and with required precautions.
CAUTION! When replacing the batteries, use the same number and type of
batteries.
CAUTION! The internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell
battery.
CAUTION! Do not dispose of batteries in a fire. The battery may explode.
CAUTION! A battery can present a risk of electric shock and a high short
circuit current. The following precaution should be observed before replacing
batteries:
- Remove watches, rings, or other metal objects.
- Use tools with insulated handles.
- Wear rubber gloves and boots.
- Do not lay tools or metal parts on top of batteries.
- Disconnect charging source prior to connecting or disconnecting batteries terminal
Installation
Connect to Utility and Charging
Plugin the AC input cord to the wall outlet. For the best results, suggest
charging the battery at least 6 hours before initial use. The unit charges its
battery while connecting to the utility.
Connect the Loads
Simply plug one bulb into the lamp holder on the unit. Then, press “Power
switch” on the back panel to turn on the power. If necessary, you may plug
other 3 lamp holder cables into output sockets for 3 more bulbs.
Operation
Power On/Off
Once the unit has been properly installed, press the power switch to turn on
the unit. The unit will work automatically inline mode or battery mode
according to input utility power’s status. After pressing the power switch
again, the unit will be turned off.
LED Indicators
There are three indicators (Green/Red/Yellow) on the unit.
Indicators | No. Of LEDs | 3 LEDs |
---|---|---|
AC Mode | Green LED | |
Battery Mode | Yellow LED Light Continuous ON | |
Low Battery | Yellow LED Light On/Off every 1 second | |
Overload | Red LED Light On/Off every 0.5 second | |
Fault | Red LED Continuous ON |
Specifications
Capacity | (VANV) | 50VA/40W |
---|---|---|
Input | Nominal Voltage | 220-240 VAC |
Voltage Range | 100-300 VAC | |
Frequency | 50/60 Hz (Auto Sensing) | |
Plug Type | 2 Pin Plug | |
Output | Voltage Range (AC mode) | 230DC ± 10 % |
Voltage Range (Batt. Mode) | 160-230VDC ± 10 % | |
Frequency Range (Batt. Mode) | 50/60Hz ±1% | |
Transfer Time | 100ms | |
Waveform (Battery mode) | DC Output | |
No. of Output Sockets | 3 | |
Protections | Overload, Short Circuit, Over-Discharge & Over Charge | |
Battery | Battery Type | 12V 7Ah x 1 no |
Charging Current | 1A | |
Recharge Time | 6 hours to charge 90% (after complete discharge) | |
Physical Details | Dimension (W x D x H) | 200 x 87 x 209 mm |
Net Weight | 2.7 kg | |
Package Dimension (W x D x H) | 266 x 127 x 275 mm | |
Environmental Factors | Operational Temperature | 0A00C |
Noise Level | < 40dB |
Trouble Shooting
Problem | Possible Cause | Solutions |
---|---|---|
The unit cannot be turned on during power failure. | The battery voltage is too | |
low. | Charge the unit at least 4 hours. | |
Battery defect. | Replace the batteries. | |
Utility power is normal but the units are in battery mode. | AC input power | |
cord is not connected well. | Check AC input power connection. | |
The input fuse is blown. | Replace the input fuse. | |
The lamp holder is not working. | The unit is not turned on. | Press the power |
switch to turn on the unit.
The power switch for the lamp holder is not turned on.| Turn on the power
switch of the lamp holder.
When power fails, the backup
time is shorter.| The unit is overloaded.| Remove some non-critical loads.
The battery voltage is too low.| Charge the unit at least 4 hours.
Battery capacity is not full even after charging the unit for at least 8
hours.| Check the date code of the battery. If the batteries are too old,
replace the batteries.
No LED display on the front panel when the utility power is normal.| The
battery is not connected well.| Check the external battery cable and terminal.
Make sure all the battery connections to the unit areall correct.
Battery defect.| Replace the batteries.
Red LED is flashing for 0.5 seconds every second.| The unit is overloaded.|
Remove some non-critical loads and turn on the unit again.
If there is any abnormal situations occur, which doesn’t list above, please call the service people immediately for a professional examination.
ISO 9001:2015 Certified Company
www.zebronics.com
Documents / Resources
|
ZEBRONICS ZEB-CU5013 Portable CFL
UPS
[pdf] User Manual
ZEB-CU5013, Portable CFL UPS, ZEB-CU5013 Portable CFL UPS, CFL UPS, UPS
---|---
|
ZEBRONICS ZEB-CU5013 Portable CFL
UPS
[pdf] User Manual
ZEB-CU5013, Portable CFL UPS, ZEB-CU5013 Portable CFL UPS
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>