warmup KW-BLR2CH konekt Wireless Boiler 2-Channel Switch User Manual
- October 27, 2023
- Warmup
Table of Contents
- Package Contents
- Information about this manual
- Hazard information
- Function and device overview
- General system information
- Mounting
- Startup
- Troubleshooting
- Restore factory settings
- Maintenance and Cleaning
- General information about radio operation
- Declaration of Conformity
- Technical specifications
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KW-BLR2CH konekt Wireless Boiler 2-Channel Switch
User Manual
Package Contents
Quantity | Description |
---|
1
4
4
1| Warmup konekt Wireless Boiler 2-Channel Switch
Screws 3.0 x 30 mm
Wall Plugs 5 mm
Quick Start Guide
Information about this manual
This manual should be read carefully before commencing operation of your
konekt wireless products. Always retain the product manuals for future use.
Symbols used:
Hazard indication
Important
information
Hazard information
Do not open the devices except as instructed to by the installation and
operation manuals. It does not contain any user serviceable components.
The device is suitable for indoor use only. It must not be exposed to
moisture, vibrations, mechanical loads or temperatures outside of its rated
values.
For safety and licensing reasons (CE/UKCA), unauthorised change and/or
modification of the device(s) is not permitted. The device and its packaging
are not toys; do not allow children to play with them. Small components such
as batteries and packaging preset a risk of choking or suffocation.
Using the devices, in any way or for any purpose, other than those described
in their installation and operation manuals invalidates any warranty or
liability.
This device is part of the building installation and must only be installed by
appropriately qualified and competent persons in accordance with local
regulations and standards.
To prevent risk of electric shock, the devices must be disconnected from the
mains supply and discharged before conducting any works. Safeguard against the
supply being switched back on throughout works.
Non-compliance with the installation instructions may result in a fire or an
electric shock.
The device may only be used for fixed installations. The devices must be
securely attached within a fixed installation.
Ensure all cables connected to the device are correctly sized and rated.
Do not exceed the rated loads of the device or any individual output.
Manuals for 3rd party devices connected to these, such as heat sources, valves
and circulators, must be followed and complied with to ensure compatibility.
This device
is intended for use in residential, business and commercial properties only.
The device
does not require product specific maintenance. To clean, use a soft, clean and
lint-free cloth. To remove more stubborn marks, dampen the cloth with warm
water. Do not use detergents or chemicals on the devices.
Function and device overview
The knoekt wireless Boiler Switch provides interlock for:
- UFH demand
- Radiator demand
- DHW scheduling
- Heating and Cooling changeover
- Dehumidification demand
Where more than 2 channels are required multiple switches can be used.
Device overview:
(A) System button (Pairing button and LED)
(B) Cover
(C & D) Supply Live and Neutral terminals (230 V AC / 50 Hz, 6A)
(E) PE terminals
(F) Switching channel OUT1 (N.O contact)
(G) Switching channel OUT2 (change-over contact)
General system information
The Boiler Switch is part of the Warmup konekt Wireless System. Devices in the konekt Wireless System system can be easily paired and setup through the konekt Wireless Smart Hub using the konekt App. All functions of the konekt Wireless System are described in detail in the User Guide. The User Guide and Online manuals for all other konekt Wireless devices are available on www.warmup.co.uk
Mounting
You can flexibly mount the boiler switch for heating systems on walls using the supplied screws and plugs.
-
Open the cover (B) by removing the screws, (1) at the bottom and then (2) pulling the cover down and then up.
-
Use a pen to mark the four bore holes of the switch onto the wall where you plan to mount it.
-
Using a suitable drill, make 4 x 5mm holes as shown.
-
Use the supplied screws and plugs to secure the switch to the wall.
Startup
6.1 Pre-installation information
This device is part of the building installation and must only be installed by
appropriately qualified and competent persons in accordance with local
regulations and standards.
To prevent risk of electric shock, the devices must be disconnected from the
mains supply and discharged before conducting any works. Safeguard against the
supply being switched back on throughout works.
Non-compliance with the installation instructions may result in a fire or an
electric shock.
Max. cross sections for Boiler Switch terminals C to F
Rigid cable | Flexible cable with/without ferrule |
---|---|
1.0 – 2.5 mm² | 1.0 – 2.5 mm² |
Max. cross sections for Boiler Switch terminals G
Rigid cable| Flexible cable with/without ferrule
1.0 – 1.5 mm²| 0.5 – 1.0 mm²
The permitted cable diameter for all cable bushings are 8 to 11 mm.
6.2 Wiring information
The boiler
switch must be configured in the konekt wireless App. The function of
switching channel OUT1 (F) and if required, switching channel OUT2 (G) will
need to be assigned using the App.
Once paired to the Smart Hub you will be asked to assign this function. See
section 6.3 to pair the device to the Smart Hub.
6.2.1 Connect Only UFH or Only Rads
UFH only assignment | Rads only assignment |
---|---|
OUT1 | OUT1 |
Heating and cooling demand for floor heating actuators | Heat demand for rooms |
6.2.2 Connect UFH with Rads or DHW
Rads & DHW assignment | UFH with DHW assignment |
---|---|
OUT1 | OUT1 |
Heating and cooling demand for floorheating actuators | Heating and cooling |
demand for floor heating actuators
OUT2| OUT2
Heat demand for rooms| Hot water demand
6.2.3 Connect Rads & DHW
Rads & DHW assignment
OUT1
Heat demand for rooms
OUT2
Hot water demand
6.2.4 Connect air dehumidifier
Air dehumidifier assignment
OUT1
Dehumidification for floor heating actuators
6.3 Pairing the device to the Smart Hub
The wiring centre can be paired seamlessly to the konekt Wireless Smart Hub
(KW-UKHUB). To pair devices to the Smart Hub please download the konekt app.
The Smart
Hub must be set up via the konekt App, before any other devices can be added
to your system. For further information, refer to the Smart Hub operating
manual.
If you have
already connected the wiring centre to other konekt Wireless device(s), you
MUST restore its factory settings first before you can connect it to the Smart
Hub (see section 8)
- Open the konekt wireless App and select Pair device.
- If required, press the system button (A) once. The LED will flash orange to indicate pairing mode. Pairing mode will remain active for three minutes.
- Your device will automatically appear in the konekt App. To confirm, scan the QR code attached to the device or alternatively enter the last four digits of the device number (SGTIN) in the App.
- If pairing is successful the LED (B) will light up green. If it lights red please try to pair the device again.
- In the App, give the device a name and allocate it to a room.
- In the App select the functions of the boiler switch. See section 6.2 for more information on assigning the functions of the boiler switch.
Troubleshooting
7.1 Command not confirmed
If at least one device does not accept a command, the LED (B) will light up
red. This may be caused by radio interference (see section 10). Other possible
issues may be:
- Device cannot be reached.
- Device is unable to execute the command (load failure, mechanical block, etc.).
- Device is defective.
7.2 Duty cycle
The duty cycle is a legally regulated limit of the transmission time of
devices in the 868 MHz range. The aim of this regulation is to safeguard the
operation of all devices working in the 868 MHz range. In the 868 MHz
frequency range we use, the maximum transmission time of any device is 1% of
an hour (i.e. 36 seconds in an hour). Devices must cease transmission when
they reach the 1% limit until this time restriction comes to an end.
Warmup devices are designed and produced with 100% conformity to this
regulation. During normal operation, the duty cycle is not usually reached.
However, intensively repeated device pairing processes may mean that this
limit is reached in isolated instances during commissioning.
IMPORTANT: If the duty cycle limit is exceeded, the device may stop
working for a brief period. The device will start working normally again after
a short period (max. 1 hour).
7.3 Error codes and flashing sequences
Flashing sequences of the system LED (A)
Flashing code 1 | Meaning | 1 Solution |
---|---|---|
Short orange flashing | Radio transmission/ attempting to transmit/ | |
configuration data is transmitted | Wait until the transmission is completed. | |
lx long green light | Transmission confirmed | You can continue operation. |
lx long red light | Transmission failed or duty cycle reached | Please try again |
(See section 7.1 and 7.2)
Short orange flashing
(every 10 s)| Pairing mode active| Enter the last four numbers of the device
serial number to confirm
6x long red flashing| Device defective| Have a look at your app for error
message or contact your installer.
lx orange and 1 x green lighting| Test display| Once the test display has
stopped, you can continue.
Restore factory settings
The factory settings of the device can be restored. The device will automatically reconnect to the system and redownload its settings unless it is deleted within the konekt App first.
- Press and hold the system button (A) for 4 seconds until it begins to quickly flash orange.
- Release the system button
- Press and hold the system button again until the system button LED lights green
- Release the system button to finish the factory reset.
Maintenance and Cleaning
The device does not require any specific maintenance other than replacing the battery when necessary. To clean, use a soft, clean and lint-free cloth. To remove more stubborn marks, dampen the cloth with warm water. Do not use detergents or chemicals on the devices.
General information about radio operation
Radio transmission is performed on a non-exclusive RF channel, which means
that there is a possibility of interference occurring. Interference can also
be caused by switching operations, electrical motors or defective electrical
devices.
The range of
transmission within buildings can differ greatly from that available in the
open air. Besides the transmitting power and the reception characteristics of
the receiver, environmental factors such as humidity in the vicinity have an
important role to play, as do on-site structural/screening conditions.
Declaration of Conformity
Warmup hereby declares that the Warmup konekt Wireless radio equipment is compliant with RED Directive 2014/53/EU and Radio Equipment Regulations 2017. Please scan the QR Code for the Declaration of Conformity.
Instructions for Disposal
Do not dispose of the device(s) with regular domestic waste! Electronic
equipment must be disposed of at local collection points for waste electronic
equipment in ompliance with the Waste Electrical and Electronic Equipment
Directive.
Technical specifications
Warmup konekt Wireless Boiler 2-Channel Switch
Product Code | KW-BLR2CH |
---|---|
Operating Voltage | 230 V AC / 50 Hz |
Current Consumption | 16 A max. |
Standby Power Consumption | < 0.2 W |
IP Rating | IP20 |
Protection Class | I |
Ambient Temperature | 0 to 50 °C |
Load Type | Ohmic load |
Max. Switching Capacity
Switching Channel 1
Switching Channel 2| 16 A (3680 W)
5 A(1150 W)
Method of Operation| 1.B
Cycle Rating| 10,000
Relay| Changeover contact:
SPDT, p contact Normally open contact:
SPST, p contact
Withstand Voltage| 2500 V
Radio frequency band| 868.0-868.6 MHz, 869.4-869.65 MHz
Maximum radiated power| 10 dBm
Receiver category| SRD category 2
Typ. open area RF range| 250 m
Duty cycle| < 1% per h/, < 10% per h
Construction| Independently mounted electronic regulation and control
device
Degree of Pollution| 2
Warranty
Warmup plc warrants theses product(s), to be free from defects in the
workmanship or materials, under normal use and service, for a period of three
(3) years from the date of purchase by the consumer. If at any time during the
warranty period the product is determined to be defective,
Warmup shall repair or replace it, at Warmup’s option.
If the product is defective, please either;
Return it, with a bill of sale or other dated proof of purchase, to the place
from which you purchased it, or
Contact Warmup. Warmup will determine whether the product should be returned
or replaced.
This warranty does not cover removal or re-installation costs and shall not
apply if it is shown by Warmup that the defect or malfunction was caused by
failure to follow the instruction manuals, incorrect installation or damage
which occurred while the product was in the possession of a consumer. Warmup’s
sole responsibility shall be to repair or replace the product within the terms
stated above.
WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM
ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE
THREE-YEAR DURATION OF THIS WARRANTY.
This Warranty does not affect your statutory rights.
b Warmup plc
www.warmup.co.uk
uk@warmup.com
Tel: 0345 345 2288
Fax: 0345 345 2299
Warmup plc n 704 Tudor Estate n Abbey Road n London n NW10 7UW n UK
Warmup GmbH n Ottostraße 3 n 27793 Wildeshausen n DE
Warmup – OM – KW_Boiler Switch – V1.2 2021-06-04_EN
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>