Warmup TH115-AF-GA Programmable Thermostat Owner’s Guide

October 30, 2023
Warmup

Warmup TH115-AF-GA Programmable Thermostat

View all Warmup thermostat manual

Before you start

Read the entire document

CAUTION

  • Installation must be carried out by a certified electrician and must comply with national and local electrical codes.
  • Use this thermostat for resistive loads only.
  • Do NOT install the thermostat in an area where it can be exposed to water or rain.
  • To prevent severe shock or electrocution, always turn the power Off at the service panel before working with the wiring.
  • Install the thermostat onto an electrical box.
  • Use special CO/ALR solderless connectors if you connect the thermostat to aluminum wires.
  • Keep the thermostat’s top and bottom air vents (openings) clean and unobstructed at all times.

About your thermostat

The TH115 programmable thermostat has three temperature control modes

  • A mode:
    • controls the ambient air temperature
  • F mode:
    • controls the floor temperature using an external temperature sensor
  • AF mode:
    • controls the ambient air temperature
    • maintains the floor temperature within desired limits using an external temperature sensor

Supplied Parts

  • One (1) thermostat
  • Two (2) mounting screws
  • Four (4) solderless connectors for copper wires
  • One (1) floor sensor
  • One (1) flat-tip screwdriver

Controls

Warmup-TH115-AF-GA,-Programmable-Thermostat-FIG.1

  • Place at Off to cut power to the heater (e.g., in the summer). This will not affect the time and temperature settings.
  • When the backlight button or either of the  buttons is pressed, the display illuminates for 12 seconds.

Display

Warmup-TH115-AF-GA,-Programmable-Thermostat-FIG.2

  • The thermostat normally displays the actual (measured) temperature. To view the setpoint temperature, briefly press either of the buttons. The setpoint will appear for 5 seconds. To change the setpoint temperature, press one of the buttons until the desired temperature is displayed. To scroll faster, press and hold the button.

Installing the thermostat

Warmup-TH115-AF-GA,-Programmable-Thermostat-FIG.3

  1. Turn the heating system off at the main electrical panel.
  2. Loosen the bottom screw and remove the thermostat faceplate from its wallplate. (The screw cannot be completely removed.)
  3. Connect the thermostat to the load and to the power supply.
  4. Connect the floor sensor.
  5. If you wish to connect a remote control device.
  6. Install the wallplate to the electrical box using the provided screws.
  7. Set the configuration switches on the back of the faceplate.
  8. Install the faceplate back on the wall plate and tighten the screw.
  9. Apply power to the heating system.
  10. Test the ground fault protection.

Wiring diagram

NOTE:  Connect the wires using the provided solderless connectors for copper wires.

Warmup-TH115-AF-GA,-Programmable-Thermostat-FIG.4

Connecting the floor sensor / remote control

Warmup-TH115-AF-GA,-Programmable-Thermostat-FIG.5

  1. Insert the floor sensor cable through one of the two openings on the wallplate and connect the sensor wires to terminals 1 and 2 (no polarity).
    • The sensor cable must not come in contact with the electrical wires and must be routed outside the electrical box and follow the wall down to the floor.
    • Position the sensor cable such that it does not come in contact with the floor heating wires. The sensor must be centered between two-floor heating wires for best temperature control.
    • Do NOT staple the sensor head (the plastic end) to the floor. Doing so might damage the sensor. Any damage might not be noticeable during testing but can become apparent several days later.
  2. If you wish to connect a remote control device, insert the wires (use 18- to 22-gauge flexible wires) through one of the two openings on the wallplate and connect them to terminals 2 and 3 (no polarity).

Set the configuration switches

Configuration switches are on the back of the faceplate.

# Configurations Up Down
1 Display format °F / 12 h °C / 24 h
2 Early Start1 Enable Disable
3 Temperature control mode2 F AF

Warmup-TH115-AF-GA,-Programmable-Thermostat-FIG.6

  1. Early Start is used in Automatic mode only. When Early Start is enabled (on), the thermostat determines when to start heating so the Comfort temperature is attained at the beginning of periods 1 and 3. When Early Start is disabled (off), heating starts only at the beginning of periods 1 and 3; thus there is a delay before the Comfort temperature is reached.
  2. To select the F Mode, place the switch in the F position. To select the AF Mode, place the switch in the AF position and ensure that the temperature sensor is connected to the thermostat. To select the A Mode, place the switch in the AF position and ensure that the remote temperature sensor is NOT connected to the thermostat.

Time and day

To set the clock and the day

  • Press the Hour button to set the hour.
  • Press the Min button to set the minutes.
  • Press the Day button to set the day.
  • Press the Mode/Ret button to return the thermostat to normal display.

NOTE:  The thermostat will automatically return to normal display if no button is pressed for 60 seconds

Daylight Saving Time

When the Daylight Saving Time function is enabled (On), the thermostat automatically switches to Daylight Saving
Time on the second Sunday of March and to normal time on the first Sunday of November.
NOTE:  The Daylight Saving Time function is disabled (default setting) when the clock loses its setting.
To set the Daylight Saving Time function and to set the date:

  1. Press the Day button (3 seconds) until DLS appears on the screen.
  2. Press either of the  buttons to toggle between On (enabled) and Off (disabled).
  3. Press the Day button briefly. The year setting is displayed.
  4. Press either of the  buttons to set the current year.
  5. Press the Day button briefly. The month setting is displayed.
  6. Press either of the  buttons to set the current month.
  7. Press the Day button briefly. The date setting is displayed.
  8. Press either of the buttons to set the current date.
  9. Press the Mode/Ret button to return the thermostat to normal display.

NOTE:  The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Floor temperature limits (AF mode only)

WARNING:  To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor temperature limits.
The minimum and maximum floor temperature limits are 5.0°C (41°F) and 28.0°C (82°F) by default.
To modify these limits, proceed as follows:Warmup-TH115-AF-GA,-Programmable-
Thermostat-FIG.7

  1. Switch the thermostat to Off.
  2. Press and hold the  button.
  3. Switch the thermostat back to On.
  4. Release the  button when the minimum temperature limit (FL:LO) appears.
  5. Set the minimum temperature limit using the  buttons.
  6. Press the button to display the maximum temperature limit (FL:HI).
  7. Set the maximum temperature limit using the  buttons.
  8. Press Mode/Ret to return the thermostat to normal display.
    NOTE : The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Preset temperatures

The thermostat has 3 preset temperatures. Their default settings are shown in the following table

Preset temperature| Intended use| Icon| A/AF modes| F mode
---|---|---|---|---
Comfort| When at home| | 21.0°C (70°F)| 28.0°C (82°F)
Economy| When asleep or away from home| | 17.0°C (63°F)| 20.0°C (68°F)
Vacation| During prolonged absence| | 10.0°C (50°F)| 10.0°C (50°F)

To use a preset temperature
Briefly press the appropriate preset temperature button . The preset temperature will become the current setpoint and its icon will appear on the screen.
To modify a preset temperature:

  • Press one of the  buttons to display the desired temperature.
  • Press and hold the appropriate preset temperature button   until its icon is displayed.

Default schedule

The schedule consists of 4 periods per day, which represents a typical work day. The Comfort (  ) preset temperature is automatically used in Periods 1 and 3 and the Economy (  ) preset temperature in Periods 2 and 4. You can program the thermostat to skip (cancel) the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend.
NOTE:  If you wish to use only 2 periods, use the following combinations: “1 and 4” or “2 and 3”. Early Start will not work with any other combinations.
You can have a different program every day; i.e., each period can start at a different time every day. The thermostat has been programmed with the following schedule.

Period| Description| Setting| MO| TU| WE| TH| FR| SA| SU
---|---|---|---|---|---|---|---|---|---
| Wake| Comfort| 6:00| 6:00| 6:00| 6:00| 6:00| 6:00| 6:00
| Leave| Economy| 8:30| 8:30| 8:30| 8:30| 8:30| –:–| –:–
| Return| Comfort| 17:00| 17:00| 17:00| 17:00| 17:00| –:–| –:–
| Sleep| Economy| 23:00| 23:00| 23:00| 23:00| 23:00| 23:00| 23:00

Modifying the schedule

Press Pgm. Period 1 for Monday is displayed.

  1. To program another period, press Pgm to display that period.
  2. To program another day, press Day to display that day (hold for 3 seconds to select the entire week).
  3. Press Hour and Min to set the period start time, or press Clear to skip (cancel) the period (–:– will be displayed).
  4. Repeat steps 2 to 4 to program another period.
  5. Press Mode/Ret to return the thermostat to normal display.
    NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Running the schedule (Automatic mode)

In Automatic mode, the thermostat follows the programmed schedule. To place the thermostat in this mode, press Mode/Ret until is displayed.

Temporary override of schedule

If you modify the setpoint temperature (by pressing the  , or  button) when the thermostat is in Automatic mode, the new temperature will be used until the beginning of the next period. flashes during the temporary override. You can cancel the temporary override by pressing Mode/Ret.

Permanent override of schedule (Manual mode)

To place the thermostat in Manual mode, press Mode/Ret to display on the screen. In this mode, the thermostat does not follow the programmed schedule. Press the  ,  or  button to set the temperature.

When you go on vacation (Vacation mode)

In this mode, the thermostat uses the vacation preset temperature (see page 13). There are two ways to
place the thermostat in Vacation mode:

  1. Press  the button on the thermostat. When the Vacation mode is activated this way, the icon appears on the screen without flashing.
  2. From any remote control device equipped with a dry contact. When the contact closes, the thermostat is placed in Vacation mode and the  icon flashes on the screen. All buttons on the thermostat are locked. When the contact opens, the thermostat returns to the previous mode.
    NOTE:  When the Vacation mode is activated from a remote control device, it can only be deactivated using the device.

Ground fault protection (GFCI)

This ground fault protection thermostat is different from conventional thermostats. In the event of a ground fault, the ground fault protection mechanism on the thermostat will trip and quickly stop the flow of electricity to prevent serious injury.
Definition of a ground fault
Instead of following its normal safe path, electricity passes through a person’s body to reach the ground. For example, a defective floor heating mat can cause a ground fault. A ground fault protection thermostat does not protect against circuit overloads, short circuits, or electrical shocks. For example, you can still receive an electrical shock if you touch bare wires while standing on a non-conducting surface such as a wood floor.
Ground fault protection reset
When the ground fault protection mechanism trips, the TEST light is On (red). To reset the ground fault protection, switch the thermostat to Off and back to On. The TEST light will turn off.

Testing the ground fault protection
To ensure the ground fault protection is always in working order, test it once the thermostat is installed and on a monthly basis thereafter.

Warmup-TH115-AF-GA,-Programmable-Thermostat-FIG.17

  • Increase the setpoint temperature above the measured temperature in order to activate the heating system.

  • Press the TEST button.

    • If the TEST light does NOT turn on, the test has failed. Cut power to the heating system at the main electrical panel, have an electrician verify the installation and, if necessary, replace the thermostat.
    • If the TEST light turns on, continue the test.
  • Switch the thermostat to Off then back to On.

    • If the TEST light turns off, the test has passed. Set the thermostat back to the desired temperature.
      The test is now completed.

    • If the TEST light remains on, the test has failed. Continue with the rest of the procedure.

  • Switch the circuit breaker (at the service panel) of the heating system to off then back to on.

  • Repeat the test. If the test fails again, cut power to the heating system at the main electrical panel, have an electrician verify the installation and, if necessary, replace the thermostat.

Error Messages

  • LO: The measured temperature is below the display range. The heating is activated.
  • HI: The measured temperature is above the display range. The heating is deactivated.
  • ERl: Verify the thermostat connection and sensor connection.

Technical Specifications

**Model| ****Supply| Max. load (resistive only)| Ground Fault Protection (GFCI)| ****Wiring
---|---|---|---|---
Current| Power
TH115-AF-GA| 120 VAC, 60 Hz| **
15 A| 1800 W| 5 mA| 4 wires, double pole
240 VAC, 60 Hz| 3600 W
TH115-AF-GB| 120 VAC, 60 Hz| 1800 W| 15 mA
240 VAC, 60 Hz| 3600 W

  • Display range: 0°C to 70.0°C (32°F to 158°F)
  • Ambient setpoint range (A/AF modes): 5.0°C to 30.0°C (40°F – 86°F)
  • Floor setpoint range (F mode): 5.0°C to 40.0°C (40°F – 104°F)
  • Floor limit range (AF mode): 5.0°C to 40.0°C (40°F – 104°F)
  • Resolution: 0.5°C (1°F)
  • Heating cycle length: 15 minutes
  • Data protection: In the event of a power failure, most settings are saved. However the time and Daylight
    Saving Time must be set if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active prior to the power failure.

Warmup TH115-AF-GA Programmable thermostat Owner’s Guide