saxby 77902 Forca Gloss White LED Emergency Bulkhead Instruction Manual

June 6, 2024
saxby

Instruction leaflet
Forca EM, MW & CCT LED
Bulkhead
77902saxby 77902 Forca Gloss White LED Emergency Bulkhead -Emergency
Bulkhead

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these
instructions for future reference.

Warning

This product is Class 2 (Double insulated) and must not be earthed.

Please read these instructions carefully before commencing any work. This unit must be fitted by a competent and qualified electrician. Install in accordance with IEE Wiring regulations and current Building Regulations.

To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.

This light fitting should be connected to a circuit with a 30mA RCD fitted. If replacing an existing fitting, make a careful note of the connections. This product contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

Technical data

Supply Voltage:| 240V~, 50 Hz| Lumens: 120Lm in EM mode
Duration: 3 hours (180 Minutes)
Operating Temperature: 0ºC – 50ºC
Maximum Operating Humdity: 90%| Change over time: Approximately 1s
Battery Specification: LifePO4 3.2V 1500mAh
Battery Charge Time: 24 Hours
Battery warranty: 2 years
---|---|---|---
Bulb Type:| 18W LED module CCT, 3000K/4200K/6500K
| Conformity with all relevant EC Directive requirements.
| Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
| The power supply is Double Insulated and does not require connection to an Earth circuit.
| This product is not suitable for dimming.
IP65| This product is rated at IP65.

Layout

  • Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the junction box and the light fitting.

  • Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas
    where they may be at risk from being cut, trapped or damaged.

  • The mains supply cable must have a minimum cross sectional area of 1.0mm²

  • Cables must be protected using suitable conduit or plastic trunking.

  • The products can be wall or ceiling mounted. If wall mounting ensure that the power supply is at the bottom.

Individual casings

The following individual casings are available for purchase separately.

77904: White plain
77905: White eyelid
77906: White grill| 77907: Grey plain
77908: Grey eyelid
77909: Grey grill| 77910: Black plain
77911: Black eyelid
77912: Black grill| 77913: Chrome plain
---|---|---|---

Installation

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.

  • Remove the 4 fixing screws and detach the shade. Keep safe for refitting later.
  • Hold the product in place and mark the position of the holes. Ensure the wall is capable of holding the weight of the product, or if fitting to a ceiling, ensure there is a joist at the point of fixing to support the weight of the product.
  • Knock out the chosen fixing holes.
  • Fix into position. Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used for brick, cavity walls or plasterboard.
  • Pierce a hole in the grommet, and pull the cable through.
  • Wire as detailed below.

Wiring

  • This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
  • Having correctly identified the wiring from your existing light fitting, connect to the quick fit connection block in the following way, using the supplied link cables where necessary.

saxby 77902 Forca Gloss White LED Emergency Bulkhead
-INSERT

Maintained (Unswitched) Wiring: The product is on permanently and comes on during a power failure

saxby 77902 Forca Gloss White LED Emergency Bulkhead
-IMaintained

Non-Maintained Wiring: The product is normally off and comes on during a power failure

saxby 77902 Forca Gloss White LED Emergency Bulkhead -The
product

Maintained (Switched) Wiring: The product is used as a normal light – switch on/off, light turns on/off.
Comes on during a power failure.saxby 779saxby 77902 Forca Gloss White LED
Emergency Bulkhead -IMaintainedz02 Forca Gloss White LED Emergency Bulkhead
-IMaintainedz

Check that…

  • You have correctly identified the wires.
  • The connections are tight.
  • No loose strands have been left out of the connection block

Commissioning

  • Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
  • Refit the shade, ensuring that the seals are correctly located.
  • Gently push your chosen casing onto the shade until it clips in place.
  • Replace fuse or circuit breaker and switch on. Your light is now ready for use.

Fitting/replacing bulbs

  • This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.

CCT Function

  • This colour is changeable between 3000K-4200K-6500K, using the switch inside the product.
A WARM WHITE 3000K
B COOL WHITE 4200K
C DAYLIGHT WHITE 6500K

Microwave Movement Sensor

This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.saxby 77902 Forca Gloss White LED Emergency
Bulkhead - detailed

saxby 77902 Forca Gloss White LED Emergency Bulkhead -
detailedu Technical Specifications:

Operating voltage 220 ~ 240V AC  50/60Hz
Rated load 400W (Capacitive load)   800W (Resistive load)
 Stand-by power ≤0.5W
Sensitivity Ceiling mounted
height: 3m 100% / 75% / 50% / 25% / 10%

 Ceiling mounted
height: 6m| 100% / 75% / 50%
Wall mounted
height: 2m| 100% / 75% / 50% / 25% / 10%
Hold-time| 5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor| 2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency| 5.8 GHz ±75MHz
Transmitting power| 1mW Max.
Detection range| Ceiling mounted
height: 3m| 3- 6m (radius )
Wall mounted
height: 1.5-2m| 12-15m
Detection angle| 360°(Ceiling) / 120°(Wall)
Working temperature|  -20°C ~ 60°C

*50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25% sensitivity is not able to detect motion signal.

Settings:

  1. Sensitivity
    Sensitivity can be adjusted by selecting the combination on the DIP switches for different applications.
    saxby 77902 Forca Gloss White LED Emergency Bulkhead
-IMaiSensitivity

  2. Hold-time
    Hold-time refers to the time period that the light remains 100% on if no more movement is detected.
    saxby 77902 Forca Gloss White LED Emergency Bulkhead - Hold-
time

  3. Daylight sensor
    Different daylight threshold can be preset on DIP switches. Light will always turn on upon movement if daylight sensor is disabled.
    saxby 77902 Forca Gloss White LED Emergency Bulkhead - Daylight
sensor

*Disable means the daylight sensor does not work. The sensor will turn on light once motion is detected regardless of ambient light level.

Trouble shooting:

Malfunction Cause Remedy Cause Remedy
The light will not come on Incorrect light-control setting selected Adjust

daylight threshold setting
Faulty lamp| Replace lamp
No power supply| Check power to sensor
The lamp is always on| Continuous movement in the detection zone| Check detection area setting
The lamp is on without any identifiable movement| The sensor is not mounted for reliably detecting movement| Securely mount enclosure
Movement occurred, but not identified by the sensor (Movement behind wall, movement of small object in immediate lamp vicinity etc.)| 1. Reduce sensitivity.
2. Check the movement behind walls to avoid facilities such as water pipe, fan, which may mis-trigger the sensor.
The lamp will not work despite movement| Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small.| Check detection area setting

Care and Safety

  • We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
  • For your safety, always switch off the power supply before cleaning.

V4 12/01/2021
www.saxbylighting.com
Saxby Lighting. BH17 7BY

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

saxby User Manuals

Related Manuals