AVSL Derby FX-Bar Portable Performance Lighting and Derby FX Rig User Manual
- June 6, 2024
- AVSL
Table of Contents
Derby FX-Bar
Portable performance lighting and derby FX rig
Due to continuous product development, please ensure that you have downloaded
the latest instruction manual for this product from the AVSL website at
www.avsl.com
For the latest instruction manual updates and information on the entire range
visit:
www.avsl.com
Thank you for purchasing this product, we are sure that it will serve you for
many years to come.
To optimise it’s performance, please read these instructions carefully to
familiarise yourself with the basic operations of the unit.
Please retain them for future reference. This unit has been tested at the
factory before being shipped to you. To prevent or reduce the risk of
electrical shock or fire, do not expose the unit to rain or moisture. To
prevent a fire hazard, do not expose the unit to any naked flame sources.
Unplug this apparatus during lightning storms or if it is unlikely to be used
for long periods of time.
When installing the unit, please ensure you leave enough space around the unit
for ventilation. Slots and openings in the unit are provided for ventilation
to ensure reliable operation of the product and to protect it from
overheating. To prevent fire hazard, the openings should never be blocked or
covered.
The unit is powered by the mains, always handle the power cable by the plug. Never pull out the plug by pulling on the cable. Never touch the power cable when your hands are wet as this could cause an electric shock. Do not tie a knot in the cable. The power cable should be placed such that it is not likely to be stepped on. A damaged power cable can cause a fire or give you an electrical shock.
Check the power cord periodicaly, if you ever find that it is damaged, replace it before using the unit again. Contact your retailer for a replacement.
The voltage of the available power supply differs according to country or region. Be sure that the power supply voltage of the area where this unit is to be used meets the requirements of the unit.
The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit’s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons. Caution: to prevent the risk of electric shock, do not attempt to open the unit. No user- serviceable parts inside. Refer all servicing to qualified service personnel. The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance. Please read and pay attention to all safety warnings on the unit.
Select the installation location of your unit carefully. Avoid placing it in direct sunlight or locations subject to vibration and excessive dust. Do not use the unit where there are extremes in temperature (below 41ºF / 5ºC or exceeding 95ºF / 35ºC).
Unpacking and safety Please unpack your new product carefully. Your new product should reach you in perfect condition. Please check that no damage has occurred during transit. If any damage is found, do not operate your unit. Please contact the retailer you purchased it from immediately. If there is any damage to the mains cable do not use the device. Always disconnect the unit from the mains supply when carrying out any cleaning of the unit.
Manufacturer Declarations
In compliance with the following requirements: RoHS Directive (2002/95/EU) and
WEEE Directive (2002/96/EU).
If this product is ever no longer functional please take it to a recycling
plant for environmentally friendly disposal.
CE declaration of conformity
R&TTE Directive (1999/5/EU), EMC Directive (2004/108/EU), Low Voltage
Directive (2006/95/EU).
Before putting the devices into operation, please observe the respective
country-specific regulations.
Overhead Rigging
Important – the installation must be carried out by qualified service personal only. Improper installation can result in serious injuries and /or damage to property. Overhead rigging required extensive experience. Working load limits should be respected, certified installation materials should be used, the installed unit should be inspected regularly for safety.
- Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.
- Locate the unit in a well ventilated spot, far away from any flammable materials and/or liquids. The fixture must be fixed at least 50cm from surrounding walls
- The device should be installed out of reach of people and outside of areas where persons may walk by or be seated.
- Before rigging make sure that the installation area can hold minimum point load of 10 times the device`s weight.
- The device should be well fixed; a free swinging mounting is dangerous.
- Do not cover any ventilation opening as this may result in overheating
Before first time use, the unit should be inspected for safety. Inspection the unit regularly every year.
AC Power
The unit is supplied with a power plug appropriate to its voltage. Should any other connections be required they must be carried out with the following configuration:
DMX-512 Connection
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain. If you wish to connect a DMX controller with other XLR outputs you will need to use adapter cables.
Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain. Always connect the the output of one unit with the input of the next unit until all units are connected.
Unit features & Functions
Function Setting
Using the four function buttons on the controller bar you can set the operating mode of the unit. Press the Menu button to display the different functions (see table below for a description of the functions). Use the Up or Down arrow buttons to make your selection. When you have chosen your desired function, press the Enter button to confirm the change.
Auto modes: AP (parcan effects) / AF (derby effects) / AN (parcan and derby
effects)
Sound to Light modes: SP (parcan effects) / SF (derby effects) / SN (parcan
and derby effects)
DMX Address Setting
When controlling the unit (or units) with a DMX controller, each one must be set with a specific DMX address. You can choose to set all units with the same DMX address or you can set every unit with its own DMX address. If all units are set with the same DMX address all units will be synchronised and operate in the same way. If you set each unit with a different DMX address, they will receive the DMX signal from their own DMX address. You will now be able to control each unit individually. The DMX address that you set for each unit must be determined by the number of channels. This unit has different options of DMX channel modes (3, 6 or 15). When working in 3 DMX channel mode, you should set the starting address of the first unit to 1, the second unit must be set to 4 (1+3), the third to 7 (4+3), the fourth to 10 (7+3) and so on. When working in 6 channel mode, you should set the starting address of the first unit to 1, the second unit must be set to 7 (1+6), the third to 13 (7+6), the fourth to 19 (13+6) and so on. When working in 15 channel mode, you should set the starting address of the first unit to 1, the second unit must be set to 16 (1+15), the third to 31 (16+15), the fourth to 46 (31+15) and so on.
3 Channel DMX Mode
NB: The DMX settings in Channel 2, relate to the 6 settings in Channel 1 (AP, AF, AN, SP, SF, SN)