avsl HPWash100 High Power Stage Blinder User Manual

June 5, 2024
AVSL

avsl HPWash100 High Power Stage Blinder User Manual
avsl HPWash100 High Power Stage Blinder

Thank you for choosing the HPWASH100, a powerful 100W white LED stage-blinder for a fully controllable light wash to stage or audience. Linear dimming control via DMX or internal programs can provide a smooth or immediate transition from blackout to full brightness. Housed in an all-metal casing with fan cooling for durability and reliable operation.

In the box:

Your HPWASH100 should arrive with you in a single carton in good condition. The carton should contain 1 x main unit with bracket, 1 x UK IEC mains lead and 1 x manual.

Warning:

To prevent risk of fire or electric shock, do not expose the unit to rain or damp environments.
In the event of a spillage, disconnect the mains and allow the unit to dry out naturally.
Qualified personnel should then check the unit before continuing use.

Please do not open cover, contains high voltage. This product is not serviceable or repairable by the end user.
Please refer to qualified personnel for service and repair.

Placement

  • Use the included mounting bracket to fix to a stand or lighting truss
  • Use secondary safety fixings if mounting overhead.
  • Keep away from damp or dusty environments
  • Ensure adequate air-flow around the fixture housings
  • Ensure adequate access to controls and connections

Cleaning:

  • Use a soft cloth with a neutral detergent to clean the casing as required
  • Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
  • Do not use strong solvents for cleaning the unit

Rear panel controls:

Rear panel controls

  1. IEC mains in (Fused)
  2. Earth screw (DO NOT REMOVE)
  3. LCD display
  4. Manual control buttons
  5. DMX signal in
  6. DMX signal out

Manual control menu:

Press the “MENU” button to enter the settings menu.
Press “UP” and “DOWN” buttons to navigate through various setting functions.
Press “ENTER” button to confirm the desired setting.

Menu Function Description
d0xx d001-d512 DMX address settings
Auxx Au01-Au03 Auto master modes left, right and both lamps
Au04-Au05 Auto master colour jump and scroll
So01 Sound activated colour jump constant
So02 Sound activated colour jump strobe
Stxx St00 Auto master constant (Au01-Au05)
  St01-St16 Auto master strobe from slow to fast (Au01-Au05)
Snxx Sn01 – Sn16 Sound activation speed adjust from slow to fast (So01

& So02)
Spxx| Sp01-Sp16| Auto master speed control (Au04 & Au05)
U0xx| u001-u255| White max brightness set low to high

DMX mode:

The HPWASH100 can be controlled by DMX signal, simply connect the DMX signal source to the DMX input on the unit via a balanced XLR lead. Extra fixtures can be controlled by the same DMX signal by looping through the DMX out on the unit. To enter DMX mode, select D001 from the menu and confirm the correct start address by using the “UP” and “DOWN” buttons and “ENTER” to confirm.
This unit has 6 DMX channels as indicated in the table below:

Channel Channel address Function
CH1 0-255 Master dimmer – low to high
CH2 1-255 Strobe – Slow to fast
CH3 1-255 Macro effects selection
CH4 0-255 Macro effects speed adjust – slow to fast
CH5 0-255 Right lamp white dimmer – low to high
CH6 0-255 Left lamp white dimmer – low to high

Specifications

Power supply 110-240Vac, 50/60Hz (IEC)
Power consumption 100W
Fuse rating F2AL, 250Vac
Light source 2x 50W White LED
DMX channels 6
Beam angle 40°
Housing Full Metal, powder painted.
Dimensions 270x135x125mm (Without bracket)
Weight 1.52kg

Troubleshooting

No power (mains) Check mains voltage is correct and outlet is switched on

Check IEC lead and fuse (if fuse continually blows, refer to your dealer)
No light output| Check control panel mode settings
Check DMX settings from controller (dimmer levels, blackout etc.)
No strobe output| Check strobe settings on control panel or from DMX controller
Unresponsive to DMX| Check that unit is in DMX mode and ensure DMX address remains lit to confirm receiving DMX signal
Check DMX controller is not set to black out
Check DMX controller is on correct fixture/page
Check master dimmer value
Check correct DMX address is set
Check DMX connection and leads
Overheating/ cutting out| Ensure adequate ventilation and unit is not too close to a heat source

This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life.
Icons
The goods must be disposed of according to your local council guidelines.

Errors and omissions excepted.
Copyright© 2021 AVSL Group Ltd, Unit 2 Bridgewater Park, AVSL (Europe) Ltd, Unit 3D North Point House,
Taylor Road, Trafford Park, Manchester. M41 7JQ. North Point Bus. Park, New Mallow Road, Cork, Ireland.

www.avsl.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals